Tear glucose levels in normal people and in diabetic patients.
Open accessAbstract
Fifty normal people and 50 diabetic patients were studied by means of an enzymatic method for the glucose content in the blood, tears, and urine before and after the peroral glucose load. In normal subjects the fasting glucose levels in the tears averaged 3.6 mg/100 ml (0.2 mmol/l) and in the diabetic patients it averaged 16.6 mg/100 ml (0.92 mmol/l). As in blood and urine, tear glucose levels are significantly higher in diabetic patients than normal persons both at fasting and after the peroral glucose load test. The fasting tear glucose level did not appear to be a satisfactory index for classifying a person as a diabetic or normal. It was found that after the peroral glucose load test a tear glucose level at 11 mg/100 ml (0.61 mmol/l) resulted in only 4.6% of the diabetics being missed, while 5.8% of the normal persons were misclassified as diabetics.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Tear glucose concentrations have been demonstrated to exhibit good correlation with blood glucose levels, reflecting diffusion from the lachrymal artery when tears are sampled without eye irritation or stimulation, which can compromise the relationship.
“In particular, tear glucose concentrations have been demonstrated to exhibit good correlation with blood glucose levels, reflecting the diffusion from the lachrymal artery when the tears are sampled without any eye irritation or stimulation, which can compromise the relationship94, 95, 99-101.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [99]
The average glucose level in tears is 0.2-0.6 mM for normal people and can exceed 0.9 mM for people with diabetes.
“The average glucose levels of tears for normal people are in the range of 0.2 to 0.6 mM, but this average can exceed 0.9 mM for people with diabetes (40)”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [40]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
USE OF GLUCOSE OXIDASE, PEROXIDASE, AND O-DIANISIDINE IN DETERMINATION OF BLOOD AND URINARY GLUCOSE
Huggett, A. S. G., & Nixon, D. A. (1957) · The Lancet · doi:10.1016/s0140-6736(57)92595-3 · Cited by 1,805 · see citing works
Concentration of Glucose and Total Chloride in Tears
Giardini, A., & Roberts, J. R. E. (1950) · British Journal of Ophthalmology · doi:10.1136/bjo.34.12.737 · Cited by 72 · see citing works
Tear Glucose Detection of Hyperglycemia
Gasset, A. R., Braverman, L. E., Fleming, M. C., Arky, R. A., & Alter, B. R. (1968) · American Journal of Ophthalmology · doi:10.1016/0002-9394(68)93093-6 · Cited by 68 · see citing works
The Intraocular Pressure and Drainage of the Aqueous Humour
Ridley, F. (1930) · PubMed Central · Cited by 55 · see citing works
Lewis, J. G., & Stephens, P. J. (1958) · British Journal of Ophthalmology · doi:10.1136/bjo.42.12.754 · Cited by 35 · see citing works
Immunoglobulins in tears of normal Indian people.
Sen, D., Gs, S., Mani, K., et al. (1976) · British Journal of Ophthalmology · doi:10.1136/bjo.60.4.302 · Cited by 26 · see citing works
Self-citationTHE INTRA-OCULAR PRESSURE AND DRAINAGE OF THE AQUEOUS HUMOUR
Ridley, F. (1931) · British Journal of Ophthalmology · doi:10.1136/bjo.15.2.102 · Cited by 24 · see citing works
Flagged first, then by citations
Research works printed but not linked: 5
- 2Giardini A, Roberts JRE. Concentration of glucose and total chlorides in tears. Br J Ophthalmol 1950; 34: 737-45.
- 4Lewis JG, Stephens PJ. Tear glucose and diabetes. Br J Ophthalmol 1958; 42: 754-8.
- 8Motoji K. The glucose content of tear fluid in normal anjd diabetic subjects. Jpn J Clin Ophthalmol 1971; 25: 1945-50.
- 9Michail D, Vancea P, Zolog N. Sur l'elimination lacry- male du glucose chez les diabetiques. C R Soc Biol (Paris) 1937; 125: 1095-9.
- '0Giardini A. Recherches sur les taux de glucose dans les larmes chez les sujets normaux et diabetiques. Boll Oculist 1948; 27: 585-99.
Cited by
Sorted by citations
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373 · see citing works
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315 · see citing works
Advances in healthcare wearable devices
Iqbal, S. M. A., Mahgoub, I., Du, E., Leavitt, M. A., & Asghar, W. (2021) · npj Flexible Electronics · doi:10.1038/s41528-021-00107-x · Cited by 714 · see citing works
Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays
Park, J., Kim, J., Kim, S.-Y., Cheong, W. H., Jang, J., Park, Y.-G., Na, K., Kim, Y.-T., Heo, J. H., Lee, C. Y., et al. (2018) · Science Advances · doi:10.1126/sciadv.aap9841 · Cited by 671 · see citing works
Photonic Crystal Glucose-Sensing Material for Noninvasive Monitoring of Glucose in Tear Fluid
Alexeev, V. L., Das, S., Finegold, D. N., & Asher, S. A. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.039701 · Cited by 370 · see citing works
Chu, M. X., Miyajima, K., Takahashi, D., Arakawa, T., Sano, K., Sawada, S.-I., Kudo, H., Iwasaki, Y., Akiyoshi, K., Mochizuki, M., et al. (2011) · Talanta · doi:10.1016/j.talanta.2010.10.055 · Cited by 279 · see citing works
A flexible and wearable glucose sensor based on functional polymers with Soft-MEMS techniques
Kudo, H., Sawada, T., Kazawa, E., Yoshida, H., Iwasaki, Y., & Mitsubayashi, K. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.05.006 · Cited by 255 · see citing works
Measurement of tear glucose levels with amperometric glucose biosensor/capillary tube configuration
Yan, Q., Peng, B., Su, G., Cohan, B. E., Major, T. C., & Meyerhoff, M. E. (2011) · Analytical Chemistry · doi:10.1021/ac201700c · Cited by 185 · see citing works
Tear glucose analysis for the noninvasive detection and monitoring of diabetes mellitus
Baca, J. T., Finegold, D. N., & Asher, S. A. (2007) · The Ocular Surface · doi:10.1016/s1542-0124(12)70094-0 · Cited by 187 · see citing works
A flexible and wearable biosensor for tear glucose measurement
Iguchi, S., Kudo, H., Saito, T., Ogawa, M., Saito, H., Otsuka, K., Funakubo, A., & Mitsubayashi, K. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9073-3 · Cited by 173 · see citing works
Mass spectral determination of fasting tear glucose concentrations in nondiabetic volunteers
Baca, J. T., Taormina, C. R., Feingold, E., Finegold, D. N., Grabowski, J. J., & Asher, S. A. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.078543 · Cited by 110 · see citing works
Biomedical soft contact-lens sensor for in situ ocular biomonitoring of tear contents
Chu, M., Shirai, T., Takahashi, D., Arakawa, T., Kudo, H., Sano, K., Sawada, S.-I., Yano, K., Iwasaki, Y., Akiyoshi, K., et al. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9530-x · Cited by 85 · see citing works
Cavitas Sensors: Contact Lens Type Sensors & Mouthguard Sensors
Mitsubayashi, K., & Arakawa, T. (2016) · Electroanalysis · doi:10.1002/elan.201600083 · Cited by 71 · see citing works
Cheng, S., Gu, Z., Zhou, L., Hao, M., An, H., Song, K., Wu, X., Zhang, K., Zhao, Z., Dong, Y., et al. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.765987 · Cited by 64 · see citing works
- Authors
- Sen, D. K., & Sarin, G. S.
- Affiliations
- Maulana Azad Medical College (IN)
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 1980-09-01
- Volume
- 64
- Issue
- 9
- Pages
- 693-695
- ISSN
- 0007-1161 (ISSN-L)
- PMC
- PMC1043796
- OpenAlex
- W2106586766
- Cited by
- 203
- References
- 7
- Citations by year
- 2026: 7 · 2025: 15 · 2024: 19 · 2023: 9 · 2022: 19 · 2021: 18 · 2020: 13 · 2019: 14 · 2018: 11 · 2017: 7 · 2016: 10 · 2015: 7 · 2014: 4 · 2013: 2 · 2012: 5
- FWCI
- 0.82
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- British Journal of Ophthalmology (publishedVersion)
- PubMed Central (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Ocular Surface and Contact Lens
- Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
- Keywords
- tear glucose, diabetes mellitus, diagnostic accuracy, tears
- MeSH terms
- Adult, Aged, Blood Glucose, Diabetes Mellitus, Female, Glucose, Glycosuria, Humans, Male, Middle Aged, Tears
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review