CFD study of exhaled droplet transmission between occupants under different ventilation strategies in a typical office room
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
This paper investigated the transmission of respiratory droplets between two seated occupants equipped with one type of personalized ventilation (PV) device using round movable panel (RMP) in an office room. The office was ventilated by three different total volume (TV) ventilation strategies, i.e. mixing ventilation (MV), displacement ventilation (DV), and under-floor air distribution (UFAD) system respectively as background ventilation methods. Concentrations of particles with aerodynamic diameters of 0.8 μm, 5 μm, and 16 μm as well as tracer gas were numerically studied in the Eulerian frame. Two indexes, i.e. intake fraction (IF) and concentration uniformity index RC were introduced to evaluate the performance of ventilation systems. It was found that without PV, DV performed best concern protecting the exposed manikin from the pollutants exhaled by the polluting manikin. In MV when the exposed manikin opened RMP the inhaled air quality could always be improved. In DV and UFAD application of RMP might sometimes, depending on the personalized airflow rate, increase the exposure of the others to the exhaled droplets of tracer gas, 0.8 μm particles, and 5 μm particles from the infected occupants. Application of PV could reduce RC for all the three TV systems of 0.8 μm and 5 μm particles. PV enhanced mixing degree of particles under DV and UFAD based conditions much stronger than under MV based ones. PV could increase the average concentration in the occupied zone of the exposed manikin as well as provide clean personalized airflow. Whether inhaled air quality could be improved depended on the balance of pros and cons of PV.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Chao, C. Y. H., Li, Y., & Katoshevski, D. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.11.002 · Cited by 1,129 · cited 2×
“[17] found that non-equilibrium droplet evaporationwas not detectable for particles between 0.”
BackgroundChao, C. Y. H., Wan, M. P., Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Li, Y., Xie, X., et al. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.10.003 · Cited by 1,087 · cited 1×
“[18] reported that the geometric mean diameter of exhaled droplets was 13.”
BackgroundLi, Y., Leung, G. M., Tang, J. W., Yang, X., Chao, C. Y. H., Lin, J. Z., Lu, J. W., Nielsen, P. V., Niu, J., Qian, H., et al. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2006.00445.x · Cited by 1,055
Self-citationToward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens
Nicas, M., Nazaroff, W. W., & Hubbard, A. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620590918466 · Cited by 867 · cited 1×
“However, the diameters of exhaled droplets may span a wide range from O(1 mm) to O (1000 mm) [16].”
BackgroundMODELING INDOOR PARTICLE DEPOSITION FROM TURBULENT FLOW ONTO SMOOTH SURFACES
K. Lai, A. C., & Nazaroff, W. W. (2000) · Journal of Aerosol Science · doi:10.1016/s0021-8502(99)00536-4 · Cited by 696 · cited 1×
“To consider particle deposition process at solid boundaries, a semi-empirical deposition model proposed by Lai and Nazaroff was used [25] .”
MethodNazaroff, W. W. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00286.x · Cited by 639 · cited 2×
“This is because particles in this study were among the accumulation model and coarse model [30] .”
BackgroundTransmission of infectious diseases during commercial air travel
Mangili, A., & Gendreau, M. A. (2005) · The Lancet · doi:10.1016/s0140-6736(05)71089-8 · Cited by 535
Melikov, A. K. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00284.x · Cited by 399
Modeling particle distribution and deposition in indoor environments with a new drift–flux model
Chen, F., Yu, S. C. M., & Lai, A. C. K. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.09.044 · Cited by 347
Modeling particle dispersion and deposition in indoor environments
Gao, N. P., & Niu, J. L. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.01.016 · Cited by 273 · cited 2×
“The back one was an exposed person (denoted as E) which inhaled airflow at 6 l/min through the mouth (20 Â 10 mm) at 45 upward.”
MethodSelf-citationChen, C., & Zhao, B. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2009.00626.x · Cited by 251 · cited 2×
“[29] Chen C, Zhao B.”
BackgroundHuman response to personalized ventilation and mixing ventilation
Kaczmarczyk, J., Melikov, A., & Fanger, P. O. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00300.x · Cited by 212
Prediction of particle deposition onto indoor surfaces by CFD with a modified Lagrangian method
Zhang, Z., & Chen, Q. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.09.041 · Cited by 180
Transport of particulate and gaseous pollutants in the vicinity of a human body
Rim, D., & Novoselac, A. (2009) · Building and Environment · doi:10.1016/j.buildenv.2008.12.009 · Cited by 168 · cited 1×
“Although the breathing rate is various in different studies [20] , the experimental results of Rim and Novoselac [28] indicated that breathing of a sedentary manikin has little influence on the airflow field in the breathing zone and it has very small impact on the occupant's thermal plume.”
ResultPerformance of Personalized Ventilation in Conjunction with Mixing and Displacement Ventilation
Cermak, R., Melikov, A. K., Forejt, L., & Kovar, O. (2006) · Science and Technology for the Built Environment · doi:10.1080/10789669.2006.10391180 · Cited by 144 · cited 3×
“6 compares simulated concentrations of tracer gas to experimental data obtained from Cermak and Melikov [13] under DV at two measuring positions near the polluting and the exposed manikins (A and B in Fig.”
BackgroundMethodResultInfluentialControl of airborne infectious diseases in ventilated spaces
Nielsen, P. V. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0228.focus · Cited by 141
CFD Study of the Thermal Environment around a Human Body: A Review
Gao, N. P., & Niu, J. L. (2005) · Indoor and Built Environment · doi:10.1177/1420326x05050132 · Cited by 138
Self-citationPersonalized ventilation as a control measure for airborne transmissible disease spread
Pantelic, J., Sze-To, G. N., Tham, K. W., Chao, C. Y. H., & Khoo, Y. C. M. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0311.focus · Cited by 136 · cited 4×
“Pantelic et al. [12] found the protective role of PV for an exposed manikin against droplets released from a ‘coughing machine’ in three distances experimentally.”
BackgroundInfluentialWan, M. P., Sze-To, G. N., Chao, C. Y. H., Fang, L., & Melikov, A. K. (2009) · Aerosol Science and Technology · doi:10.1080/02786820802641461 · Cited by 132 · cited 1×
“[7] studied dispersion and deposition of expiratory aerosol experimentally and numerically under typical airflow patterns in an aircraft cabin.”
BackgroundGao, N., Niu, J., & Morawska, L. (2008) · Building Simulation · doi:10.1007/s12273-008-8328-0 · Cited by 118 · cited 1×
“[5] studied spatial concentration distribution and temporal evolution of exhaled and sneezed/coughed droplets within the range of 1.0e10.0 mm in an office room with mixing ventilation (MV), displacement ventilation (DV) and under-floor air distribution (UFAD).”
BackgroundSelf-citationSze To, G. N., Wan, M. P., Chao, C. Y. H., Fang, L., & Melikov, A. (2009) · Aerosol Science and Technology · doi:10.1080/02786820902736658 · Cited by 117 · cited 1×
“[6] and Wan et al.”
Cermak, R., & Melikov, A. K. (2007) · Science and Technology for the Built Environment · doi:10.1080/10789669.2007.10390942 · Cited by 105 · cited 1×
“The front one was a polluting source (denoted as P) which exhaled infected airflow at 6 l/min and 35 C [14] through the mouth (20 Â 10 mm) [27] at 45 downward [22] .”
BackgroundTransport and Removal of Expiratory Droplets in Hospital Ward Environment
Chao, C. Y. H., Wan, M. P., & To, G. N. S. (2008) · Aerosol Science and Technology · doi:10.1080/02786820802104973 · Cited by 93 · cited 1×
“[8] investigated transport and removal characteristics of expiratory droplets in a three bed hospital ward with MV under different ventilation rates and coughing orientations.”
BackgroundNumerical modeling of exhaled droplet nuclei dispersion and mixing in indoor environments
Mui, K. W., Wong, L. T., Wu, C. L., & Lai, A. C. K. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2009.01.041 · Cited by 91 · cited 1×
“[10] investigated transmission of exhaled droplet nuclei between a polluting manikin and a receiver under MV and DV in an empty room.”
BackgroundHan, K., Zhu, X., He, F., Liu, L.-G., Zhang, L., Ma, H., Tang, X., Huang, T., Zeng, G. Q., & Zhu, B. (2009) · Emerging infectious diseases · doi:10.3201/eid1510.091013 · Cited by 81
Calculating the potential for within-flight transmission of influenza A (H1N1)
Wagner, B. G., Coburn, B. J., & Blower, S. (2009) · BMC Medicine · doi:10.1186/1741-7015-7-81 · Cited by 77
Study of expiratory droplet dispersion and transport using a new Eulerian modeling approach
Lai, A. C. K., & Cheng, Y. C. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.05.045 · Cited by 73 · cited 1×
“The front one was a polluting source (denoted as P) which exhaled infected airflow at 6 l/min and 35 C [14] through the mouth (20 Â 10 mm) [27] at 45 downward [22] .”
BackgroundCharacterizing Sources of Indoor Air Pollution and Related Sink Effects
Tichenor, B. A. (1996) · doi:10.1520/stp1287-eb · Cited by 68
Melikov, A. K., Cermak, R., Kovar, O., & Forejt, L. (2003) · Cited by 50
Transport of exhaled particulate matter in airborne infection isolation rooms
Richmond‐Bryant, J. (2008) · Building and Environment · doi:10.1016/j.buildenv.2008.01.009 · Cited by 47 · cited 1×
“Richmond [9] numerically studied dispersion of exhaled pathogen-laden droplets by a patient through both continuous breathing and single coughing in an airborne infection isolation room with MV. Mui et al.”
BackgroundExperimental analysis of particle concentration heterogeneity in a ventilated scale chamber
Jin, H., Li, Q., Chen, L., Fan, J., & Lu, L. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2009.06.002 · Cited by 14 · cited 1×
“[26] measured the heterogeneity of particle concentrations in a ventilated scaled-chamber with dimensions of width  depth  height ¼ 1 m  1 m  0.3 m (Fig.”
BackgroundInfluentialHan, K., Zhu, X., He, F., Liu, L.-G., Zhang, L., Ma, H., Tang, X., Huang, T., Zhu, B., & Zeng, G. (2010) · PubMed · Cited by 3
Cited by
Vuorinen, V., Aarnio, M., Alava, M., Alopaeus, V., Atanasova, N., Auvinen, M., Balasubramanian, N., Bordbar, H., Erästö, P., Grande, R., et al. (2020) · Safety Science · doi:10.1016/j.ssci.2020.104866 · Cited by 472
“…Liu et al., 2017) that may have an association with ventilation (Li et al., 2005; Olmedo et al., 2012; Cao et al., 2015), airflow interaction (Bivolarova et al., 2017; Li et al., 2018a; Ai et al., 2019), in hospitals (Yu et al., 2005; King et al., 2015; Cho, 2019) and offices (He et al., 2011).”
BackgroundFeng, Y., Marchal, T., Sperry, T., & Yi, H. (2020) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2020.105585 · Cited by 406
Balachandar, S., Zaleski, S., Soldati, A., Ahmadi, G., & Bourouiba, L. (2020) · International Journal of Multiphase Flow · doi:10.1016/j.ijmultiphaseflow.2020.103439 · Cited by 191
A review of different ventilation modes on thermal comfort, air quality and virus spread control
Fan, M., Fu, Z., Wang, J., Wang, Z., Suo, H., Kong, X., & Li, H. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.108831 · Cited by 168
“[102] conducted a CFD study on respiratory pollutants in human body models, and found that clean areas formed at lower positions, while polluted areas formed at higher positions.”
Modeling the Impacts of Physical Distancing and Other Exposure Determinants on Aerosol Transmission
Wagner, J., Sparks, T. L., Miller, S., Chen, W., Macher, J. M., & Waldman, J. M. (2021) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2021.1963445 · Cited by 21
“The aerosol trajectories that govern short-range transmission have been modeled for numerous, complex environments using computational fluid dynamics (CFD) and mannequin tracer studies (e.g., He et al. 2011; Li et al. 2020; Poon and Lai 2011).”
Method
Metadata
- Authors
- He, Q., Niu, J., Gao, N., Zhu, T., & Wu, J.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2011-02
- Volume
- 46
- Issue
- 2
- Pages
- 397-408
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W2089932589
- Cited by
- 186
- References
- 32
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.