The influence of human walking on the flow and airborne transmission in a six-bed isolation room: Tracer gas simulation
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
By performing unsteady CFD simulations using RNG k–ɛ model and dynamic mesh technique, this paper investigates how the walking motion of health care worker (HCW) influences gaseous dispersion in a six-bed isolation room with nine downward supplies and six ceiling-level or floor-level exhausts. The flow near and behind HCW is easily affected by HCW motion. The flow disturbance induced by HCW walking with swinging arms and legs is a mixing process. The walking HCW displaces air in front of it and carries air in the wake forwardly, meanwhile pressure difference drives air from two lateral sides into the wake. HCW motion (0–5.4 s) indeed induces a little gaseous dispersion, but the residual flow disturbance after HCW stops (5.4 s–25.4 s) induces more gaseous agent spread and it requires more than 30–60 s to approximately recover to the initial state after HCW stops. Although HCW motion indeed affects airborne transmission, but its effect is less important than ventilation design. No matter with or without HCW motion, the ceiling-level exhausts perform much better in controlling airborne transmission than the floor-level exhausts with the same air change rate (12.9 ACH). Smaller air change rate of 6 ACH experiences higher concentration and more gaseous spread than 12.9 ACH. In contrast to the realistic human walking, the simplified motion of a rectangular block produces stronger flow disturbance. Finally surface heating of HCW produces a stronger thermal body plume and enhances turbulence near HCW, thus slightly strengthens airborne transmission.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Compendium of physical activities: an update of activity codes and MET intensities
AINSWORTH, B. E., HASKELL, W. L., WHITT, M. C., IRWIN, M. L., SWARTZ, A. M., STRATH, S. J., O???BRIEN, W. L., BASSETT, D. R., SCHMITZ, K. H., EMPLAINCOURT, P. O., et al. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00009 · Cited by 8,497 · cited 1×
“[40], and the key parameters include the frequency f1⁄4 0.”
BackgroundComputational Methods for Fluid Dynamics
Ferziger, J. H., Peric, M., & Leonard, A. (1997) · Physics Today · doi:10.1063/1.881751 · Cited by 6,005
Computational methods for fluid dynamics
(2003) · Computers & Mathematics with Applications · doi:10.1016/s0898-1221(03)90046-0 · Cited by 1,160
Li, Y., Leung, G. M., Tang, J. W., Yang, X., Chao, C. Y. H., Lin, J. Z., Lu, J. W., Nielsen, P. V., Niu, J., Qian, H., et al. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2006.00445.x · Cited by 1,055
Self-citationVentilation performance prediction for buildings: A method overview and recent applications
Chen, Q. (2009) · Building and Environment · doi:10.1016/j.buildenv.2008.05.025 · Cited by 957 · cited 1×
“Some literature [3,21,22] provided good reviews.”
Zhang, Z., Zhang, W., Zhai, Z. J., & Chen, Q. Y. (2007) · HVAC&R Research · doi:10.1080/10789669.2007.10391460 · Cited by 746 · cited 1×
“[44,45] reported that the RNG ke 3model [42] was one of the best turbulencemodels”
BackgroundTang, J. W., Li, Y., Eames, I., Chan, P. K. S., & Ridgway, G. L. (2006) · Journal of Hospital Infection · doi:10.1016/j.jhin.2006.05.022 · Cited by 667
Self-citationNazaroff, W. W. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00286.x · Cited by 639
Flow dynamics and characterization of a cough
Gupta, J. K., Lin, C.-H., & Chen, Q. (2009) · Indoor Air · doi:10.1111/j.1600-0668.2009.00619.x · Cited by 605 · cited 1×
“[47,48] found that themomentum of exhalation was important for coughing but not significant for breathing and talking.”
BackgroundCharacterizing exhaled airflow from breathing and talking
Gupta, J. K., Lin, C.-H., & Chen, Q. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2009.00623.x · Cited by 564 · cited 1×
“[47,48] found that themomentum of exhalation was important for coughing but not significant for breathing and talking.”
BackgroundZhao, B., Zhang, Y., Li, X., Yang, X., & Huang, D. (2003) · Building and Environment · doi:10.1016/j.buildenv.2003.08.002 · Cited by 447
Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong
Li, Y., Huang, X., Yu, I. T. S., Wong, T. W., & Qian, H. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00317.x · Cited by 414
Self-citationBjørn, E., & Nielsen, P. V. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.08126.x · Cited by 294
Qian, H., Li, Y., Nielsen, P. V., Hyldgaard, C. E., Wong, T. W., & Chwang, A. T. Y. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00407.x · Cited by 294 · cited 1×
“[14] and Yin et al.”
Self-citationChen, C., & Zhao, B. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2009.00626.x · Cited by 251
Particle deposition indoors: a review
Lai, A. C. K. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01159.x · Cited by 226
Gao, N. P., Niu, J. L., Perino, M., & Heiselberg, P. (2008) · Building and Environment · doi:10.1016/j.buildenv.2007.10.023 · Cited by 188
Numerical study of the transport of droplets or particles generated by respiratory system indoors
Zhao, B., Zhang, Z., & Li, X. (2005) · Building and Environment · doi:10.1016/j.buildenv.2004.09.018 · Cited by 183
The ventilation of multiple-bed hospital wards: Review and analysis
Beggs, C. B., Kerr, K. G., Noakes, C. J., Hathway, E. A., & Sleigh, A. (2008) · American Journal of Infection Control · doi:10.1016/j.ajic.2007.07.012 · Cited by 170
Dispersion of exhalation pollutants in a two-bed hospital ward with a downward ventilation system
Qian, H., Li, Y., Nielsen, P. V., & Hyldgaard, C. E. (2008) · Building and Environment · doi:10.1016/j.buildenv.2006.03.025 · Cited by 169 · cited 1×
“Previous investigations on mixing ventilations in hospital isolation rooms [17,18] suggested that, if the upward thermal body plumes are considered in an isolation roomwith downward supply air streams, the ceiling-level exhausts are more efficient than the floor-level exhausts in reducing airborne transmissions.”
BackgroundSelf-citationPoussou, S. B., Mazumdar, S., Plesniak, M. W., Sojka, P. E., & Chen, Q. (2010) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.04.053 · Cited by 158 · cited 1×
“[27] and Mazumdar et al.”
Personal Exposure in Displacement Ventilated Rooms
Brohus, H., & Nielsen, P. V. (1996) · Indoor Air · doi:10.1111/j.1600-0668.1996.t01-1-00003.x · Cited by 152 · cited 1×
“The displacement ventilation has been considered effective and widely used for indoor air quality control in general indoor environments [20], however in hospital isolation rooms, Qian et al.”
BackgroundTang, J. W.-T., Noakes, C. J., Nielsen, P. V., Eames, I., Nicolle, A., Li, Y., & Settles, G. S. (2010) · Journal of Hospital Infection · doi:10.1016/j.jhin.2010.09.037 · Cited by 150
Self-citationQian, H., & Li, Y. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2010.00653.x · Cited by 149 · cited 12×
“This grid arrangements are similar with those in our previous CFD simulations [18] and those in the literature [31,32].”
BackgroundMethodResultInfluentialSelf-citationCFD Study of the Thermal Environment around a Human Body: A Review
Gao, N. P., & Niu, J. L. (2005) · Indoor and Built Environment · doi:10.1177/1420326x05050132 · Cited by 138
Large-eddy simulation of human-induced contaminant transport in room compartments
Choi, J., & Edwards, J. R. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2011.00741.x · Cited by 116 · cited 4×
“Choi and Edward [29,30] performed large eddy simulations to explore how realistic human walking affects indoor airflows and contaminant transport between two rooms through a door way and the shared hall or vestibule.”
BackgroundMethodInfluentialWang, J., & Chow, T. T. (2011) · Building and Environment · doi:10.1016/j.buildenv.2011.04.008 · Cited by 114
Tang, J. W.-T., Eames, I., Li, Y., Taha, Y., Wilson, P., Bellingan, G. J., Ward, K. N., & Breuer, J. (2005) · Journal of Hospital Infection · doi:10.1016/j.jhin.2005.05.017 · Cited by 113
Self-citationState-of-the-art methods for studying air distributions in commercial airliner cabins
Liu, W., Mazumdar, S., Zhang, Z., Poussou, S. B., Liu, J., Lin, C., & Chen, Q. (2011) · Building and Environment · doi:10.1016/j.buildenv.2011.07.005 · Cited by 98
Large eddy simulation and zonal modeling of human-induced contaminant transport
Choi, J., & Edwards, J. R. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2008.00527.x · Cited by 88 · cited 4×
“Choi and Edward [29,30] performed large eddy simulations to explore how realistic human walking affects indoor airflows and contaminant transport between two rooms through a door way and the shared hall or vestibule.”
BackgroundMethodInfluentialCFD study on the transmission of indoor pollutants under personalized ventilation
Shen, C., Gao, N., & Wang, T. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.02.003 · Cited by 74
Computational Study of the Wake and Contaminant Transport of a Walking Human
Edge, B. A., Paterson, E. G., & Settles, G. S. (2005) · Journal of Fluids Engineering · doi:10.1115/1.2013291 · Cited by 71
Movement of airborne contaminants in a hospital isolation room
Eames, I., Shoaib, D. S. M., Klettner, C. A., & Taban, V. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0319.focus · Cited by 65
Chen, C., Zhao, B., Yang, X., & Li, Y. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0486 · Cited by 62
Self-citationMazumdar, S., Yin, Y., Guity, A., Marmion, P., Gulick, B., & Chen, Q. (2010) · Science and Technology for the Built Environment · doi:10.1080/10789669.2010.10390921 · Cited by 62
Yin, Y., Gupta, J. K., Zhang, X., Liu, J., & Chen, Q. (2010) · Building and Environment · doi:10.1016/j.buildenv.2010.07.003 · Cited by 57
Personal Exposure to Contaminant Sources in Ventilated Rooms
Brohus, H. (1997) · VBN Forskningsportal (Aalborg Universitet) · Cited by 56
An experimental study on ventilation efficiency of isolation room
Tung, Y.-C., Hu, S.-C., Tsai, T., & Chang, I.-L. (2008) · Building and Environment · doi:10.1016/j.buildenv.2008.03.003 · Cited by 56
Numerical Investigation of Particle Diffusion in a Clean Room
Zhao, B., & Wu, J. (2005) · Indoor and Built Environment · doi:10.1177/1420326x05060190 · Cited by 53 · cited 1×
“Zhao andWu [49] found that ventilation mode, particle source location and air exchange rate play important roles on indoor particle diffusions.”
BackgroundUnsteady aerodynamic force prediction on a square cylinder using k−ε turbulence models
Lee, S. (1997) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/s0167-6105(97)00064-0 · Cited by 46
Versatile walk engine.Preprint
Boulic, R., Ulicny, B., & Thalmann, D. (2004) · Cited by 31
Cited by
Enhanced spread of expiratory droplets by turbulence in a cough jet
Wei, J., & Li, Y. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.06.018 · Cited by 321
Self-citation
Metadata
- Authors
- Hang, J., Li, Y., & Jin, R.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2014-07
- Volume
- 77
- Pages
- 119-134
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W1980475519
- Cited by
- 181
- References
- 41
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.