Challenges in developing ventilation and indoor air quality standards: The story of ASHRAE Standard 62
Open accessAbstract
Building ventilation has long been recognized for its role in occupant health, comfort and productivity, with some of the first recommendations on building ventilation rates published in the 19 th century. These recommendations were subsequently transformed into more rigorous standards and guidance in the 20 th century, with the first version of ASHRAE Standard 62 published in 1973. Since that time, ventilation standards have been issued in several countries around the world and have dealt with an increasingly complex and challenging range of issues as research on indoor air quality and the state of knowledge of building performance have progressed. This paper reviews and discusses some of the issues that have been addressed in the development of ventilation standards in recent years using the development of ASHRAE Standard 62 as context, including: the scientific bases for ventilation requirements, perceived indoor air quality, contaminant sources from occupants and the building, outdoor air quality, airborne contaminant limits, indoor carbon dioxide concentrations, environmental tobacco smoke, and performance-based design. Issues that are expected to be dealt with as Standard 62 and other standards are developed into the future are also reviewed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Following the basic ventilation standards for indoor spaces such as schools and kindergartens, we noticed that they are designed to dilute bio-effluents and achieve basic levels of acceptable indoor air quality rather than to control infection [4].”
From Bacteria Filtration Efficiency for Different Types of Protective Face Masks (2023) · cites this paper as [4]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schwarz, S. (1941) · Columbia University Press eBooks · doi:10.7312/schw92626-009 · Cited by 4,698
Ventilation for Acceptable Indoor Air Quality
Falih, M. (2019) · Cited by 2,497
Satish, U., Mendell, M. J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., & Fisk, W. J. (2012) · Environmental Health Perspectives · doi:10.1289/ehp.1104789 · Cited by 1,064
Ventilation rates and health: Multidisciplinary review of the scientific literature
Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., et al. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00703.x · Cited by 740
Associations between classroom CO2 concentrations and student attendance in Washington and Idaho
Shendell, D. G., Prill, R., Fisk, W. J., Apte, M. G., Blake, D., & Faulkner, D. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00251.x · Cited by 462
Fanger, P. O. (1988) · Energy and Buildings · doi:10.1016/0378-7788(88)90051-5 · Cited by 372
Apte, M. G., Fisk, W. J., & Daisey, J. M. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004246.x · Cited by 341
Ventilation and performance in office work
Seppanen, O., Fisk, W. J., & Lei, Q. H. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00394.x · Cited by 303
Mendell, M. J., Eliseeva, E. A., Davies, M. M., Spears, M., Lobscheid, A. B., Fisk, W. J., & Apte, M. G. (2013) · Indoor Air · doi:10.1111/ina.12042 · Cited by 302
Non-Specific Symptoms In Office Workers: A Review And Summary Of The Epidemiologic Literature
Mendell, M. J. (1993) · Indoor Air · doi:10.1111/j.1600-0668.1993.00003.x · Cited by 282
Hazard assessment of chemical air contaminants measured in residences
Logue, J. M., McKone, T. E., Sherman, M. H., & Singer, B. C. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2010.00683.x · Cited by 268
Air pollution sources in offices and assembly halls, quantified by the olf unit
Fanger, P. O., Lauridsen, J., Bluyssen, P. M., & Clausen, G. (1988) · Energy and Buildings · doi:10.1016/0378-7788(88)90052-7 · Cited by 169
Adaptation to indoor air pollution
Gunnarsen, L., & Fanger, P. O. (1992) · Environment International · doi:10.1016/0160-4120(92)90209-m · Cited by 147
Classroom Carbon Dioxide Concentration, School Attendance, and Educational Attainment
Gaihre, S., Semple, S. E., Miller, J. D., Fielding, S., & Turner, S. (2014) · Journal of School Health · doi:10.1111/josh.12183 · Cited by 131
Ventilation requirements in buildings—I. Control of occupancy odor and tobacco smoke odor
Cain, W. S., Leaderer, B. P., Isseroff, R., Berglund, L. G., Huey, R. J., Lipsitt, E. D., & Perlman, D. (1983) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(83)90341-4 · Cited by 112
The Right to Healthy Indoor Air
Mølhave, L., & KRZYZANOWSKI, M. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004211.x · Cited by 51
Kretchik, J. T. (2000) · ACS Chemical Health & Safety · doi:10.1016/s1074-9098(00)00119-2 · Cited by 45
Ventilation rates in European office buildings: A review
Dimitroulopoulou, S., & Bartzis, J. G. (2013) · Indoor and Built Environment · doi:10.1177/1420326x13481786 · Cited by 38
What we Think we Know about Ventilation
Persily, A. K. (2006) · International Journal of Ventilation · doi:10.1080/14733315.2006.11683745 · Cited by 33
Field study on addition of indoor air sensory pollution sources
Wargocki, P. L., Clausen, G., & Fanger, P. O. (1996) · Cited by 8
Adaptation to Indoor Air Pollution
Gunnarsen, L. (1988) · VBN Forskningsportal (Aalborg Universitet) · Cited by 7
Persily, A. K. (2014) · Cited by 2
Reduced Outdoor Air for Auditorium: Standard 62 IAQ Procedure
Johnson, P. (2006) · ASHRAE journal · Cited by 1
Flagged first, then by citations
12 of the 36 references couldn’t be matched to a known paper.
Research works printed but not linked: 7
- Klauss, 1970, History of the changing concepts in ventilation requirements, ASHRAE J, 12, 51
- Jennings, 1971, Ventilation theory and practice, ASHRAE Trans, 77, 50
- Janssen, 1994, The V in ASHRAE: an historical perspective, ASHRAE J, 36, 126
- Janssen, 1999, The history of ventilation and temperature control, ASHRAE J, 41, 48
- Stanke, 1999, Ventilation through the years: a perspective, ASHRAE J, 41, 40
- Persily, 1997, Evaluating building IAQ and ventilation with indoor carbon dioxide, ASHRAE Trans, 103, 193
- Bridges, 2013, Application of the standard 62.1-2007 indoor air quality procedure to retail stores, ASHRAE Trans, 119, 265
Cited by
Sorted by citations
Allen, J. G., MacNaughton, P., Satish, U., Santanam, S., Vallarino, J., & Spengler, J. D. (2016) · Environmental Health Perspectives · doi:10.1289/ehp.1510037 · Cited by 977
“The > 100-year story of ventilation in buildings is complicated and was neatly summarized recently by Persily (2015).”
Direct human health risks of increased atmospheric carbon dioxide
Jacobson, T., Kler, J. S., Hernke, M. T., Braun, R., Meyer, K. C., & Funk, W. E. (2019) · Nature Sustainability · doi:10.1038/s41893-019-0323-1 · Cited by 620
Carbon dioxide generation rates for building occupants
Persily, A. K., & de Jonge, L. (2017) · Indoor Air · doi:10.1111/ina.12383 · Cited by 573
Towards sustainable, energy-efficient and healthy ventilation strategies in buildings: A review
Chenari, B., Carrilho, J. D., & da Silva, M. G. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.01.074 · Cited by 517
Kumar, P., Singh, A., Arora, T., Singh, S., & Singh, R. K. (2023) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2023.162163 · Cited by 415
Metadata
- Authors
- Persily, A.
- Affiliations
- National Institute of Standards and Technology (US)
- Corresponding author
- Persily, Andrew
- ORCID
- Persily, Andrew
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2015-09
- Volume
- 91
- Pages
- 61-69
- ISSN
- 0360-1323 (ISSN-L)
- PMC
- PMC6605073
- OpenAlex
- W1987070984
- Cited by
- 249
- References
- 36
- Citations by year
- 2026: 24 · 2025: 29 · 2024: 28 · 2023: 34 · 2022: 27 · 2021: 26 · 2020: 23 · 2019: 15 · 2018: 16 · 2017: 12 · 2016: 9 · 2015: 5
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Building and Environment (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute of Standards and Technology
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- building ventilation, indoor air quality, ventilation standards, indoor carbon dioxide, environmental tobacco smoke, outdoor air quality, performance-based design
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review