A review of different ventilation modes on thermal comfort, air quality and virus spread control
Open accessThe DOI matches its Crossref record; 83 of the 83 references it cites were found in a registry or an index.
Abstract
In the era of Corona Virus Disease 2019 (COVID-19), inappropriate indoor ventilation may turn out to be the culprit of microbial contamination in enclosed spaces and deteriorate the environment. To collaboratively improve the thermal comfort, air quality and virus spread control effect, it was essential to have an overall understanding of different ventilation modes. Hence, this study reviewed the latest scientific literature on indoor ventilation modes and manuals of various countries, identified characteristics of different ventilation modes and evaluated effects in different application occasions, wherefore to further propose their main limitations and solutions in the epidemic era. For thermal comfort, various non-uniform ventilation modes could decrease the floor-to-ceiling temperature difference, draft rate or PPD by 60%, 80% or 33% respectively, or increase the PMV by 45%. Unsteady ventilation modes (including intermittent ventilation and pulsating ventilation) could lower PPD values by 12%–37.8%. While for air quality and virus spread control, non-uniform ventilation modes could lower the mean age of air or contaminants concentration by 28.3%–47% or 15%–47% respectively, increase the air change efficiency, contaminant removal effectiveness or protection efficiency by 6.6%–10.4%, 22.6% or 14%–50% respectively. Unsteady ventilation mode (pulsating ventilation) could reduce the peak pollutant concentration and exposure time to undesirable concentrations by 31% and 48% respectively. Non-uniform modes and unsteady modes presented better performance in thermal comfort, air quality and virus spread control, whereas relevant performance evaluation indexes were still imperfect and the application scenarios were also limited.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aerodynamic Analysis of SARS-CoV-2 in Two Wuhan Hospitals
Liu, Y., Ning, Z., Chen, Y., Guo, M., Liu, Y., Gali, N. K., Sun, L., Duan, Y., Cai, J., Westerdahl, D., et al. (2020) · Nature · doi:10.1038/s41586-020-2271-3 · Cited by 1,872 · cited 1×
“), and found that a large number of viruses floated in the air as patients gathered in space with poor ventilation [7].”
Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Chao, C. Y. H., Li, Y., & Katoshevski, D. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.11.002 · Cited by 1,129 · cited 1×
“In normal breathing and conversation, 80%–90% of droplet sizes were less than 1 μm [4,5].”
Chao, C. Y. H., Wan, M. P., Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Li, Y., Xie, X., et al. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.10.003 · Cited by 1,087
Aerosol transmission of SARS-CoV-2? Evidence, prevention and control
Tang, S., Mao, Y., Jones, R. M., Tan, Q., Ji, J. S., Li, N., Shen, J., Lv, Y., Pan, L., Ding, P., et al. (2020) · Environment International · doi:10.1016/j.envint.2020.106039 · Cited by 553
A review of the performance of different ventilation and airflow distribution systems in buildings
Cao, G., Awbi, H., Yao, R., Fan, Y., Sirén, K., Kosonen, R., & Zhang, J. (. (2014) · Building and Environment · doi:10.1016/j.buildenv.2013.12.009 · Cited by 525 · cited 1×
“Traditional uniform thermal environment not only consumed more energy, but also could not meet individual needs [10].”
A review of different strategies for HVAC energy saving
Vakiloroaya, V., Samali, B., Fakhar, A., & Pishghadam, K. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2013.10.023 · Cited by 521 · cited 1×
“The method of creating uneven thermal environment attracted more attention, which allowed fresh air to be directly sent to the target area with less mixing with indoor air [27].”
Coughs and Sneezes: Their Role in Transmission of Respiratory Viral Infections, Including SARS-CoV-2
Dhand, R., & Li, J. (2020) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202004-1263pp · Cited by 409 · cited 1×
“In normal breathing and conversation, 80%–90% of droplet sizes were less than 1 μm [4,5].”
Small droplet aerosols in poorly ventilated spaces and SARS-CoV-2 transmission
Somsen, G. A., van Rijn, C., Kooij, S., Bem, R. A., & Bonn, D. (2020) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(20)30245-9 · Cited by 379
Personalized ventilation: evaluation of different air terminal devices
Melikov, A. K., Cermak, R., & Majer, M. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00102-0 · Cited by 332 · cited 3×
“PEE characterized the effectiveness of sending clean air into breathing zone [54].”
Enhanced spread of expiratory droplets by turbulence in a cough jet
Wei, J., & Li, Y. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.06.018 · Cited by 321 · cited 1×
“[83] analyzed the effect of turbulence on droplet diffusion distance of cough airflow.”
Qian, H., Li, Y., Nielsen, P. V., Hyldgaard, C. E., Wong, T. W., & Chwang, A. T. Y. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00407.x · Cited by 294 · cited 1×
“Effluent efficiency was used to denote the ability of ventilation to discharge pollutants outdoors [97].”
Airborne spread of expiratory droplet nuclei between the occupants of indoor environments: A review
Ai, Z. T., & Melikov, A. K. (2018) · Indoor Air · doi:10.1111/ina.12465 · Cited by 278 · cited 2×
“The calculation formula was as follows [96]:”
Particle Transport and Deposition: Basic Physics of Particle Kinetics
Tsuda, A., Henry, F. S., & Butler, J. P. (2013) · Comprehensive Physiology · doi:10.1002/cphy.c100085 · Cited by 264
A review of advanced air distribution methods - theory, practice, limitations and solutions
Yang, B., Melikov, A. K., Kabanshi, A., Zhang, C., Bauman, F. S., Cao, G., Awbi, H., Wigö, H., Niu, J., Cheong, K. W. D., et al. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.109359 · Cited by 259 · cited 1×
“Required high costs and inflexible locations [15].”
Influence of airborne transmission of SARS-CoV-2 on COVID-19 pandemic. A review
Domingo, J. L., Marquès, M., & Rovira, J. (2020) · Environmental Research · doi:10.1016/j.envres.2020.109861 · Cited by 244 · cited 2×
“High concentrations of air pollutants would reduce the resistance of natural immune system and made human body more vulnerable to viral diseases [2].”
He, Q., Niu, J., Gao, N., Zhu, T., & Wu, J. (2011) · Building and Environment · doi:10.1016/j.buildenv.2010.08.003 · Cited by 186 · cited 1×
“[102] conducted a CFD study on respiratory pollutants in human body models, and found that clean areas formed at lower positions, while polluted areas formed at higher positions.”
Zhang, C., Pomianowski, M., Heiselberg, P. K., & Yu, T. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110094 · Cited by 182 · cited 1×
“19 layer pollutants entering the respiratory zone [158].”
Lipinski, T., Ahmad, D., Serey, N., & Jouhara, H. (2020) · International Journal of Thermofluids · doi:10.1016/j.ijft.2020.100045 · Cited by 172
Yu, J., Ouyang, Q., Zhu, Y., Shen, H., Cao, G., & Cui, W. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2011.00746.x · Cited by 164 · cited 1×
“Furthermore, living in a stable thermal environment for a long time was unconducive to human health and weakened the adaption ability of human body to natural environment [65].”
Zhang, Y., Feng, G., Bi, Y., Cai, Y., Zhang, Z., & Cao, G. (2019) · Sustainable Cities and Society · doi:10.1016/j.scs.2019.101721 · Cited by 146 · cited 1×
“[100] found that the number of suspended viruses removed by DV was twice than that by MV.”
Shen, J., Kong, M., Dong, B., Birnkrant, M. J., & Zhang, J. “. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107926 · Cited by 138 · cited 2×
“9%, which was comparable to the virus infection prevention and control ability of air conditioning systems with 100% fresh air [89].”
Reducing the exposure risk in hospital wards by applying stratum ventilation system
Lu, Y., Oladokun, M. O., & Lin, Z. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.107204 · Cited by 138 · cited 1×
“SV could also be used to improve the ventilation of wards and reduce the exposure risk [62] as its pollutants concentration in respiratory area was lower and dilution concentration was faster.”
Personalized ventilation as a control measure for airborne transmissible disease spread
Pantelic, J., Sze-To, G. N., Tham, K. W., Chao, C. Y. H., & Khoo, Y. C. M. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0311.focus · Cited by 136 · cited 1×
“[127] used a combination of DPEV and MV.”
Dynamic characteristics and comfort assessment of airflows in indoor environments: A review
Zhu, Y., Luo, M., Ouyang, Q., Li, H., & Cao, B. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.03.032 · Cited by 130
Self-citationA systematic review of operating room ventilation
Sadrizadeh, S., Aganović, A., Bogdan, M., Wang, C., Afshari, A., Hartmann, A., Croitoru, C. V., Khan, A. I., Kriegel, M., Lind, M., et al. (2021) · Journal of Building Engineering · doi:10.1016/j.jobe.2021.102693 · Cited by 125 · cited 1×
“The combination of DV with HEPA filter was commonly used in the operating room [106].”
Gao, N., Niu, J., & Morawska, L. (2008) · Building Simulation · doi:10.1007/s12273-008-8328-0 · Cited by 118 · cited 1×
“DV thermal stratification combined with low air flow rate at the middle height of room could lead to respiratory droplets staying in the human respiratory zone for a longer time, thus possibly increasing the risk of exposure and infection [105].”
Xu, C., Wei, X., Liu, L., Su, L., Liu, W., Wang, Y., & Nielsen, P. V. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.107008 · Cited by 117 · cited 4×
“In the aspect of virus spread control, PEV should maintain high ventilation efficiency around healthy people to prevent infection [32].”
InfluentialDynamic thermal environment and thermal comfort
Zhu, Y., Ouyang, Q., Cao, B., Zhou, X. J., & Yu, J. (2015) · Indoor Air · doi:10.1111/ina.12233 · Cited by 109 · cited 1×
“Different from the tightly controlled steady thermal environment in climate chambers, real building thermal environments were usually dynamic [66].”
Tian, X., Li, B., Ma, Y., Liu, D., Li, Y., & Cheng, Y. C. (2019) · Sustainable Cities and Society · doi:10.1016/j.scs.2019.101630 · Cited by 107
Impact of impinging jet ventilation on thermal comfort and indoor air quality in office buildings
Staveckis, A., & Borodiņecs, A. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.110738 · Cited by 104
Shan, X., Zhou, J. Z., Chang, V. W.-C., & Yang, E. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.03.025 · Cited by 101 · cited 1×
“The temperature uniformity of MV was related to the high airflow speed, which also leaded to the strong blowing sense of personnel [23].”
Bolashikov, Z. D., Melikov, A. K., Kierat, W., Popiołek, Z., & Brand, M. (2012) · Science and Technology for the Built Environment · doi:10.1080/10789669.2012.682692 · Cited by 100 · cited 1×
“However, simply increasing the air change rate and adopting inappropriate ventilation strategies increased the infection risk of dense population [8,9], so the design of appropriate indoor environment was a crucial factor.”
Impact of dynamic airflow on human thermal response
Zhou, X., Ouyang, Q., Lin, G., & Zhu, Y. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00430.x · Cited by 100
Standard Procedures for Assessing Vehicle Climate with a Thermal Manikin
Wyon, D. P., Larsson, S., Forsgren, B., & Lundgren, I. (1989) · SAE Technical Paper Series · doi:10.4271/890049 · Cited by 93 · cited 1×
“, in 1985 [93] and used in 1989 [94] to evaluate the inhomogeneous thermal environment in automobiles.”
Influence of dynamic environment with different airflows on human performance
Cui, W., Cao, G., Ouyang, Q., & Zhu, Y. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.01.008 · Cited by 92
Protected zone ventilation and reduced personal exposure to airborne cross-infection
Cao, G., Nielsen, P. V., Jensen, R. L., Heiselberg, P., Liu, L., & Heikkinen, J. (2014) · Indoor Air · doi:10.1111/ina.12142 · Cited by 89 · cited 1×
“[120] found that when the air supply velocity exceeded 4 m/s, the dimensionless concentration of virus was 40% lower than that of MV, which significantly reduced the infection probability.”
Bhagat, R. K., & Linden, P. F. (2020) · Royal Society Open Science · doi:10.1098/rsos.200680 · Cited by 89
Xiao-ping, L., Niu, J., & Gao, N. (2011) · Science and Technology for the Built Environment · doi:10.1080/10789669.2011.578699 · Cited by 89 · cited 1×
“[103] proved that DV had a stronger removal ability for droplets with small particle size (<5 μm), and UFAD was more suitable for removing large droplets (5–10 μm).”
Pantelic, J., & Tham, K. W. (2013) · Science and Technology for the Built Environment · doi:10.1080/10789669.2013.842447 · Cited by 88 · cited 1×
“However, simply increasing the air change rate and adopting inappropriate ventilation strategies increased the infection risk of dense population [8,9], so the design of appropriate indoor environment was a crucial factor.”
Ahn, H., Rim, D., & Lo, L. J. (2017) · Building Simulation · doi:10.1007/s12273-017-0410-z · Cited by 87 · cited 1×
“While the energy consumption of MV was related to the location and number of diffusers, as it was more energy-saving if there were diffusers in each area for multiple areas [26].”
Kong, X., Xi, C., Li, H., & Lin, Z. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.04.045 · Cited by 87 · cited 1×
“2 m, which ensured the fresh air to be directly sent to the breath zone [40].”
Self-citationThe effect of temperature, metabolic rate and dynamic localized airflow on thermal comfort
Ugursal, A., & Culp, C. H. (2013) · Applied Energy · doi:10.1016/j.apenergy.2013.04.014 · Cited by 86
Perceptible airflow fluctuation frequency and human thermal response
Huang, L., Ouyang, Q., & Zhu, Y. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.02.004 · Cited by 80
Li, X., Niu, J., & Gao, N. (2012) · Indoor Air · doi:10.1111/ina.12005 · Cited by 80 · cited 1×
“[101] discovered that DV might be superior to MV in reducing horizontal dispersion of air droplets.”
Sze-To, G. N., Wan, M. P., Chao, C. Y. H., Wei, F., Yu, S. C. T., & Kwan, J. K. C. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2008.00544.x · Cited by 80 · cited 1×
“[124] added aerosol size, spatial non-uniform distribution characteristics and other factors into the basic dose-response model, and predicted the change of infection risk with time when an individual was at rest or in motion:”
Katramiz, E., Ghaddar, N., Ghali, K., Assaad, D. A., & Ghani, S. A. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107719 · Cited by 79 · cited 3×
“However, PEV also had some disadvantages, such as high cost and inflexible locations, and it could accelerate contaminants’ spread if PEV was used by the infected occupant [56].”
Sim, K. M., Park, H., Bae, G., & Jung, J. H. (2015) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2015.07.003 · Cited by 79 · cited 1×
“18 example, selecting an efficient fan [148], improving the insulation performance of duct [149], selecting high filter efficiency with lower wind resistance [150], using heat recovery device [151], etc.”
Berlanga, F. A., de Adana, M. R., Olmedo, I., Villafruela, J. M., Alonso, J. F. S. J., & Castro, F. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.09.100 · Cited by 78
Kabanshi, A., Wigö, H., & Sandberg, M. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.09.025 · Cited by 78 · cited 3×
“The TAPPD and TAPMV results under transient conditions were also in good agreement with the actual thermal sensation votes [72,123].”
Assaad, D. A., Ghali, K., & Ghaddar, N. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.08.005 · Cited by 76 · cited 1×
“The chilled ceiling system assisted by an intermittent PEV [125].”
CFD study on the transmission of indoor pollutants under personalized ventilation
Shen, C., Gao, N., & Wang, T. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.02.003 · Cited by 74 · cited 1×
“The interaction between PEV and DV or between PEV and UFAD was obviously stronger than that between PEV and MV [110].”
Arghand, T., Karimipanah, T., Awbi, H., Cehlin, M., Larsson, U., & Linden, E. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.04.019 · Cited by 68
An innovative personalized displacement ventilation system for airliner cabins
You, R., Zhang, Y., Zhao, X., Lin, C., Wei, D., Liu, J., & Chen, Q. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.03.057 · Cited by 67 · cited 1×
“[111] tested a PEV installed on a chair in an airplane cockpit, and found that the system had good pollutant removal potential and acceptable thermal comfort, but passengers felt cold when the air inlet was put in front of passengers’ legs.”
Liu, M., Liu, J., Cao, Q., Li, X., Liu, S., Ji, S., Lin, C., Wei, D., Shen, X., Long, Z., et al. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108590 · Cited by 65 · cited 1×
“person only/Masks worn by all passengers) [144] Did not”
A novel targeted personalized ventilation system based on the shooting concept
Gao, R., Wang, C., Li, A., Yu, S., & Deng, B. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.03.016 · Cited by 62 · cited 1×
“[109] used small directional nozzles and obtained a more uniform flow field.”
A dynamic air supply device used to produce simulated natural wind in an indoor environment
Hua, J., Ouyang, Q., Wang, Y., Li, H., & Zhu, Y. (2011) · Building and Environment · doi:10.1016/j.buildenv.2011.07.003 · Cited by 62
Self-citationInsights on critical parameters and conditions for personalized ventilation
Zhai, Z. J., & Metzger, I. (2019) · Sustainable Cities and Society · doi:10.1016/j.scs.2019.101584 · Cited by 60 · cited 1×
“Various configurations of PEV systems have been put forward, including desk-mounted, chair-integrated, under-floor and so on [31].”
Experimental investigation of thermal comfort with stratum ventilation using a pulsating air supply
Tian, X., Zhang, S., Lin, Z., Li, Y., Cheng, Y. C., & Liao, C. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106416 · Cited by 58 · cited 3×
“Air velocity comparison for different ventilation strategies [68].”
InfluentialA model-based dynamic optimization strategy for control of indoor air pollutants
Ganesh, H. S., Fritz, H., Edgar, T. F., Novoselac, A., & Bâldea, M. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.04.022 · Cited by 58 · cited 1×
“At present, costs of relevant devices were relatively high and needed to be further reduced [134].”
A comparative experimental investigation on radiant floor heating system and stratum ventilation
Li, H., Xi, C., Kong, X., Lin, Z., & Wang, L. (2019) · Sustainable Cities and Society · doi:10.1016/j.scs.2019.101823 · Cited by 57 · cited 2×
“Low energy consumption and better air quality [42].”
Self-citationZhang, Y., Han, O., Li, A., Hou, L., Olofsson, T., Zhang, L., & Lei, W. (2021) · Engineering · doi:10.1016/j.eng.2020.10.020 · Cited by 56 · cited 2×
“8 in virus spread control and air quality improvement [63].”
The Impact of Air-conditioning Usage on Sick Building Syndrome during Summer in China
Cao, B., Shang, Q., Dai, Z., & Zhu, Y. (2012) · Indoor and Built Environment · doi:10.1177/1420326x12443246 · Cited by 51 · cited 1×
“In contrast, such an environment would incur higher energy costs [64].”
Zhang, Y., Cao, G., Feng, G., Xue, K., Pedersen, C., Mathisen, H. M., Stenstad, L.-I., & Skogås, J. G. (2020) · Journal of Building Engineering · doi:10.1016/j.jobe.2020.101770 · Cited by 49 · cited 1×
“[84] studied the relationship between ACH and pollutant concentration in the operating room, and found that higher ACH significantly reduced pollutant concentration and wound exposure risk.”
Modeling non-uniform thermal environment of stratum ventilation with supply and exit air conditions
Zhang, S., Cheng, Y. C., Huan, C., et al. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.08.063 · Cited by 48 · cited 2×
“Controlled zone in the occupied area [41].”
Assaad, D. A., Habchi, C., Ghali, K., & Ghaddar, N. (2018) · Energy Conversion and Management · doi:10.1016/j.enconman.2018.02.033 · Cited by 45
Yoon, S., Kim, M., Seo, J., Kim, S., Lee, H., Lee, J., & Lee, B. J. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.110921 · Cited by 44 · cited 1×
“The third was to combine with renewable energy, such as solar energy [153] or geothermal energy [154], to reduce the utilization rate of conventional energy.”
Sui, X., Tian, Z., Liu, H., Chen, H., & Wang, D. (2021) · Journal of Building Engineering · doi:10.1016/j.jobe.2021.103040 · Cited by 42 · cited 1×
“In addition, the location relationship between tuyere, doors, windows and furniture should be fully considered to create a more reasonable air distribution and reduce the probability of air short-circuit [157].”
Kanaan, M., Ghaddar, N., Ghali, K., & Araj, G. F. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.01.029 · Cited by 41 · cited 1×
“Consequently, combining DV with upper Ultraviolet Germicidal Irradiation effectively reduced the risk of airborne viruses with minimal additional energy consumption [107,108].”
Automobile Passenger Compartment Thermal Comfort Model - Part II: Human Thermal Comfort Calculation
Ingersoll, J. G., Kalman, T. G., Maxwell, L. M., & Niemiec, R. J. (1992) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/920266 · Cited by 40 · cited 1×
“Then according to the skin area percentage of each part to the total surface area of human body, the whole PMV value was obtained by weighted average [92].”
Performance evaluation of three attached ventilation scenarios for tiny sleeping spaces
Yin, H., Li, Y., Deng, X., Han, Y., Wang, L., Yang, B., & Li, A. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.107363 · Cited by 38 · cited 10×
“When the air supply temperature increased from 19 to 21 ◦C, the MAA decreased from 475 to 443 s [116].”
InfluentialKabanshi, A., Wigö, H., Ljung, R., & Sörqvist, P. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.08.025 · Cited by 37
Ferraro, S. D., Falcone, T., Morabito, M., Messeri, A., Bonafede, M., Marinaccio, A., Gao, C., & Molinaro, V. (2021) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2021.103230 · Cited by 35 · cited 3×
“[74] conducted a “drying” test on the thermal dummy in the climate room, and studied the cooling effect of ventilation jacket.”
InfluentialLiang, C., Shao, X., Melikov, A. K., & Li, X. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.07.003 · Cited by 35
Özyoğurtçu, G., Mobedi, M., & Özerdem, B. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.02.013 · Cited by 35 · cited 1×
“18 example, selecting an efficient fan [148], improving the insulation performance of duct [149], selecting high filter efficiency with lower wind resistance [150], using heat recovery device [151], etc.”
Li, H., Li, J., Fan, M., Wang, Z., Li, W., & Kong, X. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111539 · Cited by 33 · cited 1×
“In addition, it was also an important way to reduce energy consumption to improve the utilization rate of low-grade energy and realize the cascade utilization of energy oriented by the demand of indoor environment [155].”
Self-citationHabchi, C., Ghali, K., & Ghaddar, N. (2014) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2014.05.009 · Cited by 32 · cited 1×
“When the flow rate was 60 L/s, this effect lasted until the particle diameter exceeded 10 μm [104].”
Experimental study on the effect of pulsating inflow to an enclosure for improved mixing
Fallenius, B. E. G., Sattari, A., Fransson, J. H. M., & Sandberg, M. (2013) · International Journal of Heat and Fluid Flow · doi:10.1016/j.ijheatfluidflow.2013.05.004 · Cited by 31 · cited 2×
“The ability of pulsating airflows to improve ventilation efficiency has also been theoretically validated [70].”
Draught perception in intermittent ventilation at neutral room temperature
Tawackolian, K., Lichtner, E., & Kriegel, M. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110268 · Cited by 29 · cited 2×
“Parameters to characterize an intermittent ventilation [71].”
Wang, Q., & Zhen, Z. (2006) · Engineering Computations · doi:10.1108/02644400610652965 · Cited by 22 · cited 2×
“Since the air inlet and outlet were usually located on the ceiling [17], there would be a great probability of air short-circuit due to buoyancy.”
Davey, S., Barwood, M. J., & Tipton, M. (2013) · European Journal of Applied Physiology · doi:10.1007/s00421-013-2697-5 · Cited by 18
Mneimneh, F., Ghaddar, N., Ghali, K., & Itani, M. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108356 · Cited by 12 · cited 3×
“Components and structures of the hybrid vest [75].”
InfluentialEffects of simulated natural air movement on thermoregulatory response during head-down bed rest
Yang, Z., Fei, J., Song, D., Zhao, Y., Yu, J., & Yu, X.-J. (2013) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2013.04.006 · Cited by 9
Liu, T., Liu, Z., Li, G., & Zuo, Z. (2015) · Procedia Engineering · doi:10.1016/j.proeng.2015.09.031 · Cited by 8 · cited 1×
“Personalized ventilation (PEV) PEV could provide personalized air supply to send fresh and conditioned air into the occupied zone directly [30].”
Metadata
- Authors
- Fan, M., Fu, Z., Wang, J., Wang, Z., Suo, H., Kong, X., & Li, H.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2022-03
- Volume
- 212
- Pages
- 108831
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W4210596691
- Cited by
- 168
- References
- 83
- FWCI
- 19.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.