Evolution and performance analysis of adaptive thermal comfort models – A comprehensive literature review
Open accessThe DOI matches its Crossref record; 112 of the 112 references it cites were found in a registry or an index.
Abstract
Thermal comfort is fundamental to indoor environmental design and operation as well as indoor thermal environment evaluation. This paper has reviewed the historic evolution of thermal comfort research during the last century using a systematic approach and a particular focus on adaptive thermal comfort studies. A large number of published articles as well as standards and guides were collected and screened based on a rigorous search method to ensure the literature database was both focused and complete. A further evaluation of representative prediction models has been conducted by applying the models to a large database and comparing the differences in their performance. Based on the review analysis, three representative thermal environment assessment approaches were classified as the heat balance approach, the adaptive regression-based approach and the adaptive heat balance approach. The strengths and constraints of each approach were analyzed. Comparisons of different models in the adaptive heat balance approach were conducted using the ASHRAE databases I&II. Thermal comfort theory and approaches have been developed which underpin standards and guidelines in building and engineering system design, operation and evaluation though there are pros and cons of different methods. The heat balance approach features the detailed parameters of design criteria of indoor thermal environments. The adaptive regression-based approach played an important role in raising awareness of adaptive capacities and paved the way towards first implementations into standardization. The adaptive heat balance approach combines the heat balance and the adaptive regression approaches and leads towards future improvements in adaptive comfort modelling. It demonstrates very good performance and its inclusive approach offers potential for further breakthroughs in reducing the limitations of the existing methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
bibliometrix: An R-tool for comprehensive science mapping analysis
Aria, M., & Cuccurullo, C. (2017) · Journal of Informetrics · doi:10.1016/j.joi.2017.08.007 · Cited by 23,235 · cited 1×
“1 developed by Aria and Cuccurullo [15] to present the “big picture” of how 1333 documents in the previous section reveal the causes of adaptive thermal comfort model evolutionary movements, for instance, the impact due to economic, social activities and green and sustainability movement.”
BackgroundFast unfolding of communities in large networks
Blondel, V. D., Guillaume, J.-L., Lambiotte, R., & Lefebvre, E. (2008) · Journal of Statistical Mechanics: Theory and Experiment · doi:10.1088/1742-5468/2008/10/p10008 · Cited by 21,424 · cited 1×
“Specifically, the Louvain method [16] was used as the clustering algorithm in the co-occurrence network, which measures the density of links within communities and between communities.”
MethodDavid, F. N., & Tukey, J. W. (1977) · Biometrics · doi:10.2307/2529486 · Cited by 12,708
Comparison of PubMed, Scopus, Web of Science, and Google Scholar: strengths and weaknesses
Falagas, M. E., Pitsouni, E. I., Malietzis, G. A., & Pappas, G. (2008) · The FASEB Journal · doi:10.1096/fj.07-9492lsf · Cited by 5,039 · cited 1×
“1 Data selection In the selection process, we searched two A&I (abstract and index) databases, Web of Science and Scopus, because they cover most publications in science fields [13].”
MethodThermal comfort: Analysis and applications in environmental engineering
(1972) · Applied Ergonomics · doi:10.1016/s0003-6870(72)80074-7 · Cited by 4,451
(1998) · eScholarship (California Digital Library) · Cited by 1,934
Science Mapping: A Systematic Review of the Literature
Chen, C. (2017) · Journal of Data and Information Science · doi:10.1515/jdis-2017-0006 · Cited by 1,925 · cited 1×
“The overwhelming volume of new information, scientific publications, conceptual developments and data has brought challenges for accumulating knowledge and collecting evidence through previous research papers [14].”
BackgroundAdaptive thermal comfort and sustainable thermal standards for buildings
Nicol, J. F., & Humphreys, M. A. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00006-3 · Cited by 1,850 · cited 1×
“The fundamental assumption of the adaptive principle is “if a change occurs such as to produce discomfort, people react in ways which tend to restore their comfort” [39].”
BackgroundThermal adaptation in the built environment: a literature review
Brager, G. S., & de Dear, R. J. (1998) · Energy and Buildings · doi:10.1016/s0378-7788(97)00053-4 · Cited by 1,483 · cited 1×
“At some level, the static heat balance model can be considered as being partially adaptive in the behavioural sense since it accounts for clothing, activity level and indoor climatic parameters which can be adjusted by the occupants [8].”
A standard predictive index of human response to the thermal environment
Gagge, A. P., Fobelets, A. P. R., & Berglund, L. G. (1986) · ASHRAE winter conference papers · Cited by 1,053
Extension of the PMV model to non-air-conditioned buildings in warm climates
Ole Fanger, P., & Toftum, J. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00003-8 · Cited by 853 · cited 6×
“Terms and conditions for use of this material are defined in the End User Agreement . www.reading.ac.uk/centaur CentAUR Central Archive at the University of Reading Reading’s research outputs online Evolution and performance analysis of adaptive thermal comfort models – a comprehensive literature review Runming Yao a,…”
BackgroundMethodInfluentialSelf-citationAn Effective Temperature Scale Based on a Simple Model of Human Physiological Regulatory Response
Gagge, A. P. (1971) · ASHRAE winter conference papers · Cited by 798
Forty years of Fanger’s model of thermal comfort: comfort for all?
van Hoof, J. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2007.00516.x · Cited by 733 · cited 1×
“These included the unavailability of accurate values of input parameters [35]; misapplication in individuals or a small group [36]; limitations of extending its”
BackgroundThe validity of ISO-PMV for predicting comfort votes in every-day thermal environments
Humphreys, M. A., & Fergus Nicol, J. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00018-x · Cited by 709 · cited 15×
“Nicol and Roaf [55] 1996 Office NV Tcomf = 0.38 Tout +17.0 Occupants in Pakistan show large variations in desired indoor temperature.”
BackgroundMethodResultInfluentialA theoretical adaptive model of thermal comfort – Adaptive Predicted Mean Vote (aPMV)
Yao, R., Li, B., & Liu, J. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.02.014 · Cited by 709 · cited 6×
“Several researchers attempted to bridge the gap between the heat balance approach and the adaptive regression-based approach, which include the nPMV model [9], ePMV model [10], aPMV model [11], and ATHB model [12].”
BackgroundMethodInfluentialSelf-citationAdaptive Thermal Comfort: Principles and Practice
Nicol, F., Humphreys, M., & Roaf, S. (2012) · doi:10.4324/9780203123010 · Cited by 636
Analysis of the accuracy on PMV – PPD model using the ASHRAE Global Thermal Comfort Database II
Cheung, T., Schiavon, S., Parkinson, T., Li, P., & Brager, G. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.01.055 · Cited by 566 · cited 1×
“The PMV index has been challenged over the last two decades as the deviation of the prediction accuracy in a so-called ‘real environment’ observed in field studies [12] [34].”
BackgroundNicol, F., & Humphreys, M. (2009) · Building and Environment · doi:10.1016/j.buildenv.2008.12.013 · Cited by 551
Kim, J., Schiavon, S., & Brager, G. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.01.023 · Cited by 522 · cited 1×
“These included the unavailability of accurate values of input parameters [35]; misapplication in individuals or a small group [36]; limitations of extending its”
BackgroundThe adaptive model of thermal comfort and energy conservation in the built environment
de Dear, R., & Schiller Brager, G. (2001) · International Journal of Biometeorology · doi:10.1007/s004840100093 · Cited by 516 · cited 23×
“Nicol and Roaf [55] 1996 Office NV Tcomf = 0.38 Tout +17.0 Occupants in Pakistan show large variations in desired indoor temperature.”
BackgroundInfluentialDevelopment of the ASHRAE Global Thermal Comfort Database II
Földváry Ličina, V., Cheung, T., Zhang, H., de Dear, R., Parkinson, T., Arens, E., Chun, C., Schiavon, S., Luo, M., Brager, G., et al. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.06.022 · Cited by 481 · cited 2×
“This project systematically collected and harmonized raw data from thermal comfort field studies worldwide during the last two decades since the establishment of the ASHRAE Database I [112].”
Self-citationMapping the Evolution of Social Research and Data Science on 30 Years of Social Indicators Research
Aria, M., Misuraca, M., & Spano, M. (2020) · Social Indicators Research · doi:10.1007/s11205-020-02281-3 · Cited by 480 · cited 1×
“2 can be found in Table 2, which takes into account the occurrences per time slice of each keyword appearing in a theme [18].”
BackgroundDeveloping an adaptive control algorithm for Europe
McCartney, K. J., & Fergus Nicol, J. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00013-0 · Cited by 458 · cited 13×
“Nicol and Roaf [55] 1996 Office NV Tcomf = 0.38 Tout +17.0 Occupants in Pakistan show large variations in desired indoor temperature.”
BackgroundInfluentialAdaptive thermal comfort standards in the hot–humid tropics
Nicol, F. (2004) · Energy and Buildings · doi:10.1016/j.enbuild.2004.01.016 · Cited by 437
CBE Thermal Comfort Tool: Online tool for thermal comfort calculations and visualizations
Tartarini, F., Schiavon, S., Cheung, T., & Hoyt, T. (2020) · SoftwareX · doi:10.1016/j.softx.2020.100563 · Cited by 434 · cited 2×
“Because the ASHRAE 55 standard recommends PMVadj for evaluating the cooling effects of air movements, some papers related to PMVadj focus on developing actual software products, such as the CBE Thermal Comfort Tool developed by the University of California Berkeley [108], an educational tool for learning thermal comfo…”
MethodIndex for evaluating Heat Stress in Terms of resulting Physiological Strains.
Belding, H. S., & Hatch, T. F. (1955) · Heating, piping and air conditioning · Cited by 421
A review of thermal comfort models and indicators for indoor environments
Enescu, D. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.05.175 · Cited by 389 · cited 1×
“More detailed reviews about similar indices before the 1970s can be found in [24][25].”
BackgroundThermal comfort for naturally ventilated houses in Indonesia
Feriadi, H., & Wong, N. H. (2004) · Energy and Buildings · doi:10.1016/j.enbuild.2004.01.011 · Cited by 367 · cited 1×
“In contrast, Feriadi and Wong [122] investigated thermal comfort of occupants in Indonesian residential buildings and found that the most popular adaptive strategies were: opening windows (78%), drinking or changing clothes (70% to 60%), taking a bath or going to a cooler place (29%), and using air conditioning (AC) (…”
BackgroundHumphreys, M., Rijal, H. B., & Nicol, F. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.01.024 · Cited by 367 · cited 1×
“the vertical axis and the horizontal axis” [124].”
BackgroundTowards a psycho-physiological model of thermal perception
Auliciems, A. (1981) · International Journal of Biometeorology · doi:10.1007/bf02184458 · Cited by 358 · cited 1×
“that in spring because of previous hot and cold thermal experiences in summer and winter [46].”
BackgroundManu, S., Shukla, Y., Rawal, R., Thomas, L., & de Dear, R. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.12.019 · Cited by 347 · cited 2×
“Since the publication of the adaptive principles, researchers worldwide have adopted this method to develop specific linear expressions, as shown in Appendix A, which covered different countries, climates, building types and occupants, such as for Pakistan [55] [56], Iran [57], China [58] [59] [60] [61] [62] [63], Tun…”
MethodThermal comfort as part of a self-regulating system
Nicol, J. F., & Humphreys, M. A. (1973) · Building Research and Practice · doi:10.1080/09613217308550237 · Cited by 287 · cited 11×
“Humphreys [132] 1981 Residential, office & classroom NV Tcomf = 0.55 Tout +14.1 Mean indoor temperature is highly correlated to the comfort temperature.”
BackgroundInfluentialLiu, H., Wu, Y., Li, B., Cheng, Y., & Yao, R. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.01.066 · Cited by 272 · cited 3×
“Good agreements of the aPMV prediction with actual observations have been found in [40], [87], [88].”
BackgroundResultSelf-citationDamiati, S. A., Zaki, S. A., Rijal, H. B., & Wonorahardjo, S. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.09.024 · Cited by 265 · cited 1×
“[118] in 2016 also confirmed this finding in the South East Asia region, with the exception of Malaysia, which exhibited a trend of lower neutral temperature than standard recommendations.”
ResultAre ‘class A’ temperature requirements realistic or desirable?
Arens, E., Humphreys, M. A., de Dear, R., & Zhang, H. (2010) · Building and Environment · doi:10.1016/j.buildenv.2009.03.014 · Cited by 260
Adaptive model of thermal comfort for offices in hot and humid climates of India
Indraganti, M., Ooka, R., Rijal, H. B., & Brager, G. S. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.01.002 · Cited by 257 · cited 2×
“[79] 2014 Office HVAC & NV NV: Tcomf=0.”
MethodClimatic variations in comfortable temperatures: the Pakistan projects
Nicol, J. F., Raja, I. A., Allaudin, A., & Jamy, G. N. (1999) · Energy and Buildings · doi:10.1016/s0378-7788(99)00011-0 · Cited by 242 · cited 1×
“Since the publication of the adaptive principles, researchers worldwide have adopted this method to develop specific linear expressions, as shown in Appendix A, which covered different countries, climates, building types and occupants, such as for Pakistan [55] [56], Iran [57], China [58] [59] [60] [61] [62] [63], Tun…”
MethodAdaptive Thermal Comfort: Foundations and Analysis
Humphreys, M., Nicol, F., & Roaf, S. (2015) · Routledge eBooks · doi:10.4324/9781315765815 · Cited by 240
Adaptive thermal comfort model for different climatic zones of North-East India
Singh, M. K., Mahapatra, S., & Atreya, S. (2011) · Applied Energy · doi:10.1016/j.apenergy.2011.01.019 · Cited by 234 · cited 1×
“2011 [91] Three Climatic zones, India 12 λ values ranged from 1.”
BackgroundDetermining lines of equal comfort
Houghten, F. C. (1923) · Medical Entomology and Zoology · Cited by 232
de Dear, R. J., Leow, K. G., & Foo, S. C. (1991) · International Journal of Biometeorology · doi:10.1007/bf01041840 · Cited by 229 · cited 7×
“As standard-based projects (RP-884 [126], SCATs [52]) were mostly conducted in office buildings, their applicability in other building types still requires further verifications. de Dear et al. [71] found the acceptable temperature range for Sydney residents falls 2 to 3 K on the cool side of ASHRAE 55 adaptive regres…”
BackgroundInfluentialAn adaptive thermal comfort model for hot humid South-East Asia
Nguyen, A. T., Singh, M. K., & Reiter, S. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.03.021 · Cited by 228
Nudging the adaptive thermal comfort model
Parkinson, T., de Dear, R., & Brager, G. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2019.109559 · Cited by 216 · cited 1×
“[125] analyzed 60,321 records in the ASHRAE global database and found that the changing neutral temperature of occupants with different indoor air temperatures not only happened in NV buildings but also in HVAC and MM buildings, indicating that the fixed and narrow PMV range may not well represent the thermal comfort…”
BackgroundYao, R., Liu, J., & Li, B. (2009) · Applied Energy · doi:10.1016/j.apenergy.2009.09.028 · Cited by 214 · cited 1×
“[89] who investigated thermal comfort in naturally ventilated classrooms and Li et al.”
BackgroundSelf-citationField studies of thermal comfort compared and applied
(1976) · Applied Ergonomics · doi:10.1016/0003-6870(76)90104-6 · Cited by 212 · cited 1×
“In 1978, Humphreys firstly set out the regression-based adaptive relation derived from a meta-analysis using over 30 field surveys between 1930 and 1975 with more than 200,000 records to quantitively promote the adaptive principle [49].”
MethodExpectations of indoor climate control
Fountain, M., Brager, G., & de Dear, R. (1996) · Energy and Buildings · doi:10.1016/s0378-7788(96)00988-7 · Cited by 210 · cited 1×
“The human mind has a thermal memory of environments across many timescales – seconds, minutes, hours, days and years [45].”
Dynamic predictive clothing insulation models based on outdoor air and indoor operative temperatures
Schiavon, S., & Lee, K. H. (2013) · Building and Environment · doi:10.1016/j.buildenv.2012.08.024 · Cited by 208 · cited 2×
“Schiavon and Lee [41] and Schweiker and Wagner [12] also presented more dynamic models of clothing adaptation using outdoor temperature as the independent variable.”
BackgroundOutlier detection rules for fault detection in solar photovoltaic arrays
Zhao, Y., Lehman, B., Ball, R., Mosesian, J., & de Palma, J.-F. (2013) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2013.6520712 · Cited by 206 · cited 1×
“In order to assure the quality of the data selected for the comparative analysis of models, the Boxplot Outlier Rule [114], which has been proven a good method of data screening [115],”
MethodGonzalez, R. R., Nishi, Y., & Gagge, A. P. (1974) · International Journal of Biometeorology · doi:10.1007/bf01450660 · Cited by 198 · cited 1×
“Gagge [31] later directly related the SET* index to the magnitude of discomfort and discovered a clear linear relationship, indicating the possibility of linking SET* index to thermal sensation.”
BackgroundMustapa, M. S., Zaki, S. A., Rijal, H. B., Hagishima, A., & Ali, M. S. M. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.06.014 · Cited by 183
Towards an adaptive model for thermal comfort in Japanese offices
Rijal, H. B., Humphreys, M., & Nicol, F. (2017) · Building Research & Information · doi:10.1080/09613218.2017.1288450 · Cited by 176 · cited 2×
“[66] 2017 Office HVAC & MM NV: Tcomf=0.”
MethodPioneering new indoor temperature standards: the Pakistan project
Nicol, F., & Roaf, S. (1996) · Energy and Buildings · doi:10.1016/0378-7788(95)00941-8 · Cited by 165 · cited 5×
“Nicol and Roaf [55] 1996 Office NV Tcomf = 0.38 Tout +17.0 Occupants in Pakistan show large variations in desired indoor temperature.”
BackgroundMethodInfluentialIndraganti, M., Ooka, R., & Rijal, H. B. (2013) · Building and Environment · doi:10.1016/j.buildenv.2012.12.008 · Cited by 162
A comparative analysis of short-term and long-term thermal comfort surveys in Iran
Heidari, S., & Sharples, S. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00011-7 · Cited by 158 · cited 3×
“Heidari and Sharples [57] 2002 Residential & office NV Short-term study (home):Tcomf = 0.”
BackgroundMethodInfluentialThermal comfort for naturally ventilated residential buildings in Harbin
Wang, Z., Zhang, L., Zhao, J., & He, Y. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2010.08.010 · Cited by 151 · cited 1×
“Since the publication of the adaptive principles, researchers worldwide have adopted this method to develop specific linear expressions, as shown in Appendix A, which covered different countries, climates, building types and occupants, such as for Pakistan [55] [56], Iran [57], China [58] [59] [60] [61] [62] [63], Tun…”
MethodAdaptive comfort temperature model of air-conditioned building in Hong Kong
Mui, K. W., & Chan, W. T. (2003) · Building and Environment · doi:10.1016/s0360-1323(03)00020-9 · Cited by 150 · cited 3×
“Mui and Chan [58] 2003 Office HVAC Tn = 0.”
BackgroundMethodInfluentialLiterature review on thermal comfort in transient conditions
Hensen, J. L. M. (1990) · Building and Environment · doi:10.1016/0360-1323(90)90004-b · Cited by 147 · cited 1×
“But in real environments, pure steady-state conditions are rarely encountered due to the thermal interaction between the building structure, occupancy, climate, HVAC operation and people's changing activity levels [38].”
BackgroundAn adaptive thermal comfort model for the Tunisian context: a field study results
Bouden, C., & Ghrab-Morcos, N. (2005) · Energy and Buildings · doi:10.1016/j.enbuild.2004.12.003 · Cited by 147 · cited 3×
“Bouden and Ghrab [64] 2005 Residential & office NV Tcomf =0.68 Tout +6.88 Occupants in Tunisia and North Africa show high tolerance to hot environments Ye et al. [59] 2006 Residential NV Tn=0.42 Tout +15.12 The acceptable indoor temperature in NV buildings in Shanghai, China is between 14.7 to 29.8 ℃.”
BackgroundMethodInfluentialAdaptive thermal comfort model for educational buildings in a hot-humid climate
López-Pérez, L. A., Flores-Prieto, J. J., & Rios-Rojas, C. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.12.011 · Cited by 145 · cited 2×
“López-Pérez et al. [77] 2019 Office MM NV: Tcomf=0.32Trm+18.45 AC: Tcomf=0.13Trm+22.70 The neutral temperatures of educational buildings in Mexico are 24.7 and 26.9 ℃ during AC and NV modes.”
MethodInfluentialResidential adaptive comfort in a humid subtropical climate—Sydney Australia
de Dear, R., Kim, J., & Parkinson, T. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.11.028 · Cited by 142 · cited 17×
“Williamson and Daniel [72] 2020 Residential - Tcomf=0.26𝑇𝑝𝑚𝑎+15.9 Develop a new adaptive model for residential buildings in temperate Australia.”
MethodInfluentialA study of thermal comfort in residential buildings on the Tibetan Plateau, China
Yu, W., Li, B., Yao, R., Wang, D., & Li, K. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.04.009 · Cited by 142 · cited 1×
“Good agreements of the aPMV prediction with actual observations have been found in [40], [87], [88].”
ResultSelf-citationDhaka, S., Mathur, J., Brager, G. S., & Honnekeri, A. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.11.024 · Cited by 141 · cited 10×
“10 (d), people in the hot semi-arid climate are from India, and their cultural customs may require them to consistently wear certain garments which makes their clothing level remain at a relatively high level.”
MethodInfluentialAn introduction to the Chinese Evaluation Standard for the indoor thermal environment
Li, B., Yao, R., Wang, Q., & Pan, Y. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.06.032 · Cited by 141 · cited 1×
“21) for this climate region in China's thermal comfort standard when using the aPMV model for evaluation [106].”
MethodSelf-citationA framework for an adaptive thermal heat balance model (ATHB)
Schweiker, M., & Wagner, A. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.08.018 · Cited by 140 · cited 12×
“The model has been validated with a good performance, first against the PMV index and adaptive regression model on nearly 1,200 data points from Germany and around 13,000 data points from the ASHRAE RP-884 database [12], and then against PMV, SET, and other indices on nearly 3,100 questionnaires collected in several f…”
BackgroundMethodInfluentialSelf-citation96/01038 Standards for thermal comfort. Indoor air temperature standards for the 21st century
(1996) · Fuel and Energy Abstracts · doi:10.1016/0140-6701(96)87138-4 · Cited by 138
Web application for thermal comfort visualization and calculation according to ASHRAE Standard 55
Schiavon, S., Hoyt, T., & Piccioli, A. (2013) · Building Simulation · doi:10.1007/s12273-013-0162-3 · Cited by 130 · cited 2×
“PMVadj (2014) [104] Y Y Integrate SET to PMV to evaluate the cooling effect of air movement 76”
MethodDevelopment of the adaptive PMV model for improving prediction performances
Kim, J. T., Lim, J. H., Cho, S. H., & Yun, G. Y. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.08.051 · Cited by 130
Rijal, H. B., Honjo, M., Kobayashi, R., & Nakaya, T. (2012) · Architectural Science Review · doi:10.1080/00038628.2012.744295 · Cited by 125 · cited 4×
“Rijal et al. [66] 2017 Office HVAC & MM NV: Tcomf=0.206Trm+20.8 AC: Tcomf=0.065Trm+23.9 Neutral temperatures in offices from Tokyo and Yokohama of Japan are 20 and 28 ℃ during heating and cooling modes.”
MethodInfluentialThe Measurement of Radiant Heat in Relation to Human Comfort.
Vernon, H. M. (1930) · Journal of Industrial Hygiene · Cited by 124
Revisiting individual and group differences in thermal comfort based on ASHRAE database
Wang, Z., Zhang, H., He, Y., Luo, M., Li, Z., Hong, T., & Lin, B. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110017 · Cited by 123 · cited 1×
“[127] also discovered that occupants of residential buildings can accept a much larger temperature variation than in offices or classrooms.”
BackgroundField study of a thermal environment and adaptive model in Shanghai
Ye, X. J., Zhou, Z. P., Lian, Z. W., Liu, H. M., Li, C. Z., & Liu, Y. M. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00434.x · Cited by 122 · cited 1×
“Since the publication of the adaptive principles, researchers worldwide have adopted this method to develop specific linear expressions, as shown in Appendix A, which covered different countries, climates, building types and occupants, such as for Pakistan [55] [56], Iran [57], China [58] [59] [60] [61] [62] [63], Tun…”
MethodField study on adaptive thermal comfort in mixed mode office buildings in southwestern area of Spain
Barbadilla-Martín, E., Lissén, J. M. S., Martín, J. G., Aparicio-Ruiz, P., & Brotas, L. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.06.042 · Cited by 121 · cited 2×
“BarbadillaMartín et al. [70] 2017 Office MM Tcomf=0.24Trm+19.3 A hybrid adaptive model is proposed for both NV and HVAC office buildings in Spain with a neutral temperature of around 23.6 ℃. de Dear et al. [71] 2018 Residential MM Tn=0.26𝑇𝑝𝑚𝑎+16.75 The acceptable temperature range for Sydney residents falls 2 to 3 K o…”
MethodInfluentialRupp, R. F., de Dear, R., & Ghisi, E. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.11.047 · Cited by 121 · cited 2×
“Rupp et al. [74] 2018 Office MM NV: Tcomf=0.56𝑇𝑝𝑚𝑎+12.74 AC: Tcomf=0.09𝑇𝑝𝑚𝑎+22.32 Occupants in mixed-mode buildings from southern Brazil show more tolerance to cooler and warmer environments.”
MethodInfluentialTen questions concerning future buildings beyond zero energy and carbon neutrality
Wang, N., Phelan, P. E., González, J. E., Harris, C., Henze, G. P., Hutchinson, R., Langevin, J., Lazarus, M. A., Nelson, B., Pyke, C., et al. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.04.006 · Cited by 116 · cited 1×
“climate fluctuations, by focusing more on passive solutions, such as harvesting on-site environmental resources to obtain energy for heating, cooling, lighting, and electricity before relying on mechanical and infrastructural sources [129].”
BackgroundHori, S. (1995) · The Japanese Journal of Physiology · doi:10.2170/jjphysiol.45.921 · Cited by 115 · cited 1×
“The specific physiological accommodations include instant reactions of the body to the actual thermal condition, such as vasoconstriction and vasodilation to regulate blood flow in moderate conditions, and sweating and shivering in extreme hot and cold sides [43].”
BackgroundA method to weight three categories of adaptive thermal comfort
Liu, J., Yao, R., & McCloy, R. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.12.007 · Cited by 115 · cited 1×
“Current studies on this topic usually focus on exposing human subjects to artificially controlled climate chambers instead of real environments [44].”
BackgroundSelf-citationGao, J., Wang, Y., & Wargocki, P. L. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.04.030 · Cited by 114 · cited 2×
“eSET/aSET (2015) [105] Y Y Y Y Y Y Replace PMV with SET in ePMV and aPMV 61”
MethodA new thermal comfort approach comparing adaptive and PMV models
Orosa, J. A., & Oliveira, A. C. (2010) · Renewable Energy · doi:10.1016/j.renene.2010.09.013 · Cited by 103 · cited 2×
“ePMV (2002) [10] Y Y Y Quantify thermal expectation 660 aPMV (2009) [11] Y Y Y Y Y Reveal feedback loop of thermal adaptation 554 PMVn (2011) [103] Y Statistical revision focusing on humidity 57”
BackgroundMethodPrevention of Heat Casualties in Marine Corps Recruits
Minard, D. (1961) · Military Medicine · doi:10.1093/milmed/126.4.261 · Cited by 101 · cited 1×
“Minard [28] also recognized that web bulb temperature was a better predictor of heat tolerance.”
BackgroundAirconditioning in Australia I—Human Thermal Factors
Auliciems, A., & de Dear, R. (1986) · Architectural Science Review · doi:10.1080/00038628.1988.9697267 · Cited by 99 · cited 7×
“As standard-based projects (RP-884 [126], SCATs [52]) were mostly conducted in office buildings, their applicability in other building types still requires further verifications. de Dear et al. [71] found the acceptable temperature range for Sydney residents falls 2 to 3 K on the cool side of ASHRAE 55 adaptive regres…”
BackgroundInfluentialHumphreys, & Nicol, F. (2000) · Cited by 97
Student responses to classroom thermal environments in rural primary and secondary schools in winter
Wang, D., Jiang, J., Liu, Y., Wang, Y., Xu, Y., & Liu, J. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.01.006 · Cited by 95 · cited 1×
“2017 [97] Shaanxi, Gansu, Qinghai, China -0.”
Rupp, R. F., Kim, J., Ghisi, E., & de Dear, R. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.07.048 · Cited by 92 · cited 1×
“[53] recently questioned whether the G value should always be taken as a constant.”
BackgroundLi, B., Yu, W., Liu, M., & Li, N. (2011) · Indoor and Built Environment · doi:10.1177/1420326x10394495 · Cited by 81 · cited 1×
“Since the publication of the adaptive principles, researchers worldwide have adopted this method to develop specific linear expressions, as shown in Appendix A, which covered different countries, climates, building types and occupants, such as for Pakistan [55] [56], Iran [57], China [58] [59] [60] [61] [62] [63], Tun…”
MethodSelf-citationUnderstanding occupant behaviour: the use of controls in mixed-mode office buildings
Rijal, H. B., Humphreys, M. A., & Nicol, J. F. (2009) · Building Research & Information · doi:10.1080/09613210902904221 · Cited by 79 · cited 2×
“[78] 2009 Office MM Europe transverse Database: Tcomf=0.”
MethodHeat stress indices: A review paper
Beshir, M., & Ramsey, J. D. (1988) · International Journal of Industrial Ergonomics · doi:10.1016/0169-8141(88)90012-1 · Cited by 69 · cited 1×
“More detailed reviews about similar indices before the 1970s can be found in [24][25].”
BackgroundA data-driven approach to defining acceptable temperature ranges in buildings
Li, P., Parkinson, T., Brager, G. S., Schiavon, S., Cheung, T. C. T., & Froese, T. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.02.020 · Cited by 68 · cited 1×
“[90] who analyzed the global ASHRAE database: the actual dissatisfaction rate in the cold side is lower than in the hot side which is contradictory to Fanger’s symmetric PPD curve.”
ResultIndraganti, M., & Boussaa, D. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.10.087 · Cited by 67 · cited 3×
“Indraganti and Boussaa [73] 2018 Office HVAC Tcomf=0.”
BackgroundMethodInfluentialApplication of adaptive thermal comfort methods for Iranian schoolchildren
Haddad, S., Osmond, P., & King, S. (2016) · Building Research & Information · doi:10.1080/09613218.2016.1259290 · Cited by 67 · cited 1×
“Since the publication of the adaptive principles, researchers worldwide have adopted this method to develop specific linear expressions, as shown in Appendix A, which covered different countries, climates, building types and occupants, such as for Pakistan [55] [56], Iran [57], China [58] [59] [60] [61] [62] [63], Tun…”
MethodField study on thermal comfort of passenger at high-speed railway station in transition season
Liu, G., Cen, C., Zhang, Q., Liu, K., & Dang, R. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.09.003 · Cited by 67 · cited 1×
“These λ values could indicate people’s comfort level during “motion state” and “stationary state” in the activity center [99], effects of past working experience on thermal feelings of senior and young employees in the factory [100], and different expectation patterns of passengers during waiting or transient periods…”
BackgroundSustainability in the Workplace: Nine Intervention Techniques for Behavior Change
Yun, R. J., Scupelli, P. G., Aziz, A., & Loftness, V. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-37157-8_30 · Cited by 63 · cited 1×
“The acquisition of data required for model processing could be assisted by a fast-developing technology, such as portable or wearable devices that can collect and transmit personalized data conveniently [130].”
MethodMing, R., Yu, W., Zhao, X., Liu, Y., Li, B., Essah, E., & Yao, R. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.109611 · Cited by 62
Self-citationThapa, R., Rijal, H. B., & Shukuya, M. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.03.001 · Cited by 60 · cited 2×
“[81] 2018 Temporary shelters NV Tcomf=0.”
MethodAdaptive thermal comfort model for air-conditioned hospitals in Malaysia
Yau, Y., & Chew, B. T. (2013) · Building Services Engineering Research and Technology · doi:10.1177/0143624412474829 · Cited by 55 · cited 3×
“Yau and Chew [80] 2014 Hospital HVAC Tn = 0.”
BackgroundMethodInfluentialGarcía, A., Olivieri, F., Gómez-Rubiera, E. A. L., & Ávila, P. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.05.013 · Cited by 53 · cited 2×
“García et al. [76] 2019 Office NV Tcomf=0.41 Tout +16.00 Both PMV and adaptive model do not predict well for occupants in NV office from Bogotá of Colombia.”
MethodInfluentialEnvironmental Warmth and Its Measurement
&NA;, &. (1947) · The American Journal of the Medical Sciences · doi:10.1097/00000441-194704000-00024 · Cited by 53
A new adaptive thermal comfort model for homes in temperate climates of Australia
Williamson, T., & Daniel, L. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.109728 · Cited by 52 · cited 3×
“Since the publication of the adaptive principles, researchers worldwide have adopted this method to develop specific linear expressions, as shown in Appendix A, which covered different countries, climates, building types and occupants, such as for Pakistan [55] [56], Iran [57], China [58] [59] [60] [61] [62] [63], Tun…”
MethodInfluentialThermal comfort study in prefab construction site office in subtropical China
Fu, C., Zheng, Z., Mak, C. M., Fang, Z., Oladokun, M. O., Zhang, Y., & Tang, T. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.109958 · Cited by 49 · cited 3×
“Fu et al. [83] 2020 Offices MM Winter (NV): Tcomf=0.78𝑇𝑝𝑚𝑎+9.42 The comfortable temperatures in prefab construction site offices (PCSO) are Summer (AC):Tcomf=0.18𝑇𝑝𝑚𝑎+22.89 26.1 and 21.1 ℃.”
MethodInfluentialKumar, S., Singh, M. K., Mathur, A., & Košir, M. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.109970 · Cited by 43 · cited 1×
“Since the publication of the adaptive principles, researchers worldwide have adopted this method to develop specific linear expressions, as shown in Appendix A, which covered different countries, climates, building types and occupants, such as for Pakistan [55] [56], Iran [57], China [58] [59] [60] [61] [62] [63], Tun…”
Methodcomf: An R Package for Thermal Comfort Studies
Schweiker, M. (2016) · The R Journal · doi:10.32614/rj-2016-050 · Cited by 43 · cited 10×
“Terms and conditions for use of this material are defined in the End User Agreement . www.reading.ac.uk/centaur CentAUR Central Archive at the University of Reading Reading’s research outputs online Evolution and performance analysis of adaptive thermal comfort models – a comprehensive literature review Runming Yao a,…”
MethodResultInfluentialSelf-citationCheng, B., Fu, Y., Khoshbakht, M., Duan, L., Zhang, J., & Rashidian, S. (2018) · Buildings · doi:10.3390/buildings8040049 · Cited by 40 · cited 1×
“Good agreements of the aPMV prediction with actual observations have been found in [40], [87], [88].”
ResultA discussion about thermal comfort evaluation in a bus terminal
Cardoso, V. E. M., Ramos, N., Almeida, R. M. S. F., Barreira, E., Martins, J. P., Simões, M. L., & Sanhudo, L. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.03.013 · Cited by 36 · cited 1×
“These λ values could indicate people’s comfort level during “motion state” and “stationary state” in the activity center [99], effects of past working experience on thermal feelings of senior and young employees in the factory [100], and different expectation patterns of passengers during waiting or transient periods…”
BackgroundInfluences on the predictive performance of thermal sensation indices
Schweiker, M., & Wagner, A. (2017) · Building Research & Information · doi:10.1080/09613218.2017.1256673 · Cited by 31 · cited 10×
“The model has been validated with a good performance, first against the PMV index and adaptive regression model on nearly 1,200 data points from Germany and around 13,000 data points from the ASHRAE RP-884 database [12], and then against PMV, SET, and other indices on nearly 3,100 questionnaires collected in several f…”
BackgroundMethodResultInfluentialSelf-citationSchweiker, M. (2022) · Indoor Air · doi:10.1111/ina.13018 · Cited by 30 · cited 1×
“Beyond the scope of this review was the more comprehensive performance analysis of the latest model developments [131].”
BackgroundSelf-citationComparative thermal comfort study in educational buildings in autumn and winter seasons
Liu, G., Jia, Y., Cen, C., Ma, B., & Liu, K. (2019) · Science and Technology for the Built Environment · doi:10.1080/23744731.2019.1614426 · Cited by 28
Fortuna, G., Aria, M., Piscitelli, A., Mignogna, M. D., & Klasser, G. D. (2020) · Journal of Oral Pathology and Medicine · doi:10.1111/jop.13077 · Cited by 25 · cited 3×
“2 presents the clustering results of the bibliometric analysis across three time slices (1973-2000, 2001-2010, and 2011-2022) in Sankey diagram to show how various themes were connected and developed through each time slice using the weighted inclusion index [17].”
BackgroundMethodInfluentialAnalysis on Human Adaptive Levels in Different Kinds of Indoor Thermal Environment
Song, X., Yang, L., Zheng, W., Ren, Y., & Lin, Y. (2015) · Procedia Engineering · doi:10.1016/j.proeng.2015.08.1042 · Cited by 24
EVALUATION OF THERMAL ENVIRONMENT IN SHELTERS
Lee, D. H. K., & Henschel, A. F. (1963) · Defense Technical Information Center (DTIC) · Cited by 22
Educational tool for the learning of thermal comfort control based on PMV‐PPD indices
Ruz, M. L., Garrido, J., & Vázquez, F. (2018) · Computer Applications in Engineering Education · doi:10.1002/cae.21934 · Cited by 20 · cited 1×
“Because the ASHRAE 55 standard recommends PMVadj for evaluating the cooling effects of air movements, some papers related to PMVadj focus on developing actual software products, such as the CBE Thermal Comfort Tool developed by the University of California Berkeley [108], an educational tool for learning thermal comfo…”
MethodThermal environment in the cotton textile workshop
Yang, R., Liu, L., & Ren, Y. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.06.024 · Cited by 15 · cited 1×
“These λ values could indicate people’s comfort level during “motion state” and “stationary state” in the activity center [99], effects of past working experience on thermal feelings of senior and young employees in the factory [100], and different expectation patterns of passengers during waiting or transient periods…”
BackgroundThermal Discomfort in a Tropical Environment
Webb, C. G. (1964) · Nature · doi:10.1038/2021193a0 · Cited by 15 · cited 4×
“Many important studies from such climates in South East Asia, e.g., Singapore, Malaysia, and Indonesia, have highlighted the specific adaptive approaches of local occupants for thermal comfort.”
BackgroundInfluentialLi, X., Wang, J., Zhang, W., & Chen, M. (2019) · Indoor and Built Environment · doi:10.1177/1420326x19890127 · Cited by 8 · cited 1×
“These λ values could indicate people’s comfort level during “motion state” and “stationary state” in the activity center [99], effects of past working experience on thermal feelings of senior and young employees in the factory [100], and different expectation patterns of passengers during waiting or transient periods…”
Background
Cited by
Chen, Y., Gao, J., Yang, J., Berardi, U., & Cui, G. (2023) · Applied Energy · doi:10.1016/j.apenergy.2022.120613 · Cited by 29
Metadata
- Authors
- Yao, R., Zhang, S., Du, C., Schweiker, M., Hodder, S., Olesen, B. W., Toftum, J., Romana d'Ambrosio, F., Gebhardt, H., Zhou, S., Yuan, F., & Li, B.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2022-06
- Volume
- 217
- Pages
- 109020
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W4226419061
- Cited by
- 194
- References
- 112
- FWCI
- 16.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.