The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Ionic liquid-based liquid-phase microextraction, a new sample enrichment procedure for liquid chromatography
Open accessAbstract
Room temperature ionic liquids (RTILs) were used as extraction solvent in liquid-phase microextraction (LPME) coupled with liquid chromatography. Using 1-hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]) as extraction solvent, some parameters related to LPME of 4-nonylphenol (4-NP) and 4-tert-octylphenol (4-t-OP) were optimized. Although [C6MIM][PF6] can suspend a much larger volume of drop on the needle of the microsyringe than the conventional solvents such as 1-octanol and carbon tetrachloride, the method sensitivity was analyte dependent because of the different partition coefficients and the relatively large viscosity of [C6MIM][PF6]. The proposed procedure has a detection limit and enrichment factor of 0.3 microg l(-1) and 163 for 4-NP, and 0.7 microg l(-1) and 130 for 4-t-OP, respectively. Aqueous samples including tap water, river water, and effluent from sewage treatment plant were analyzed by the proposed method and the recoveries at 10 microg l(-1) spiked level were in the range of 90-113%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Cited by
Han, X., & Armstrong, D. W. (2007) · Accounts of Chemical Research · doi:10.1021/ar700044y · Cited by 1,024
Analytical applications of room-temperature ionic liquids: A review of recent efforts
Pandey, S. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.06.038 · Cited by 756
Ionic liquids in analytical chemistry
Sun, P., & Armstrong, D. W. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.12.007 · Cited by 727
Ionic Liquids in Heterocyclic Synthesis
Martins, M. A. P., Frizzo, C. P., Moreira, D. N., Zanatta, N., & Bonacorso, H. G. (2008) · Chemical Reviews · doi:10.1021/cr078399y · Cited by 724
Application of ionic liquids in analytical chemistry
Liu, J.-F., Jiang, G.-B., Liu, J.-F., & Jönsson, J. Å. (2005) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2004.09.005 · Cited by 600
Self-citationExtraction of organic compounds with room temperature ionic liquids
Poole, C. F., & Poole, S. K. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.09.011 · Cited by 493
Pena-Pereira, F., Lavilla, I., & Bendicho, C. (2009) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2008.10.042 · Cited by 414
Ionic Liquids as Extraction Solvents: Where do We Stand?
Dietz, M. L. (2006) · Separation Science and Technology · doi:10.1080/01496390600743144 · Cited by 390
Developments in single-drop microextraction
Xu, L., Basheer, C., & Lee, H. K. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.10.073 · Cited by 382
Vortex-assisted liquid–liquid microextraction of octylphenol, nonylphenol and bisphenol-A
Yiantzi, E., Psillakis, E., Tyrovola, K., & Kalogerakis, N. (2010) · Talanta · doi:10.1016/j.talanta.2009.11.005 · Cited by 338
Chen, Y., Guo, Z., Wang, X., & Qiu, C. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.026 · Cited by 316
Ionic Liquids in Chemical Analysis
Koel, M. (2005) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408340500304016 · Cited by 290
Recent developments in solid-phase microextraction coatings and related techniques
Dietz, C., Sanz, J., & Cámara, C. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.11.041 · Cited by 280
Peng, J.-F., Liu, J.-F., Hu, X.-L., & Jiang, G.-B. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.11.006 · Cited by 276
Self-citationSingle drop microextraction—Development, applications and future trends
Jeannot, M. A., Przyjazny, A., & Kokosa, J. M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.10.089 · Cited by 276
He, L., Luo, X., Xie, H., Wang, C., Jiang, X., & Lu, K. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.09.044 · Cited by 212
The roles of ionic liquids in sorptive microextraction techniques
Aguilera-Herrador, E., Lucena, R., Cárdenas, S., & Valcárcel, M. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.11.009 · Cited by 171
Yao, C., Pitner, W. R., & Anderson, J. L. (2009) · Analytical Chemistry · doi:10.1021/ac900719m · Cited by 167
Pena-Pereira, F., Lavilla, I., Bendicho, C., Vidal, L., & Canals, A. (2009) · Talanta · doi:10.1016/j.talanta.2008.12.003 · Cited by 143
López-Darias, J., Germán-Hernández, M., Pino, V., & Afonso, A. M. (2010) · Talanta · doi:10.1016/j.talanta.2009.09.057 · Cited by 142
Stanisz, E., Werner, J., & Zgoła-Grześkowiak, A. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.06.008 · Cited by 116
Application of ionic liquid in liquid phase microextraction technology
Han, D., Tang, B., Ri Lee, Y., & Ho Row, K. (2012) · Journal of Separation Science · doi:10.1002/jssc.201200486 · Cited by 103
Liu, J., Chi, Y., & Jiang, G. (2005) · Journal of Separation Science · doi:10.1002/jssc.200401805 · Cited by 84
Self-citationIonic liquids in microextraction techniques
Vičkačkaitė, V., & Padarauskas, A. (2012) · Open Chemistry · doi:10.2478/s11532-012-0023-4 · Cited by 84
Opportunities and shortcomings of ionic liquids in single-drop microextraction
Marcinkowski, Ł., Pena-Pereira, F., Kloskowski, A., & Namieśnik, J. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.03.024 · Cited by 69
Liquid-Phase Microextraction in Bioanalytical Sample Preparation
Lucena, R., Cruz-Vera, M., Cárdenas, S., & Valcárcel, M. (2009) · Bioanalysis · doi:10.4155/bio.09.16 · Cited by 55
Single-Drop Microextraction in Bioanalysis
Choi, K., Kim, J., & Chung, D. S. (2011) · Bioanalysis · doi:10.4155/bio.11.3 · Cited by 42
Metadata
- Authors
- Liu, J.-F., Chi, Y.-G., Jiang, G.-B., Tai, C., Peng, J.-F., & Hu, J.-T.
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2004-02
- Volume
- 1026
- Issue
- 1-2
- Pages
- 143-147
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W1997260132
- Cited by
- 165
- References
- 1
- FWCI
- 8.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.