CoChat

Simultaneous qualitative and quantitative analysis of fluoroalkyl sulfonates in riverine water by liquid chromatography coupled with Orbitrap high resolution mass spectrometry

Open access
Lin, Yongfeng, Liu, Runzeng, Hu, Fanbao, Liu, Ruirui, Ruan, Ting, Jiang, Guibin · 2016 · Journal of Chromatography A
Cited by 85

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

In this study, a robust method for quick screening, confirmation and quantification analysis of eight fluoroalkyl sulfonates in surface riverine samples was developed using ultra-high performance liquid chromatography-high resolution mass spectrometer (LC-Orbitrap Tribrid HRMS). Weak anion exchange solid phase extraction was optimized to maximum recover perfluoroalkyl sulfonates (PFSAs), fluorotelomer sulfonates and the emerging 6:2 chlorinated polyfluoroalkyl ether sulfonate at the same time. Both qualitative and quantitative purposes could be achieved by simultaneous acquiring full-scan mass spectrum (MS(1)) and data-dependent MS(2) data. The LC-Orbitrap Tribrid HRMS method showed competent method detection limits for all analytes (7.1-62 pg/L) compared with the triple quadrupole mass spectrometry (LC-MS/MS) quantification method (12-54 pg/L), and satisfactory method validation results were also obtained in linearity (R(2)>0.999), trueness (88-118%), precision (2-17%) and recovery (63-103%). A good correlation (R>0.999) was found between the sets of quantified PFSA residue concentrations in thirteen estuary river samples by both the LC-Orbitrap Tribrid HRMS (0.2-440 ng/L) and LC-MS/MS (0.1-424 ng/L) methods, indicating that Orbitrap Tribrid HRMS could be used for reliable quantitative analysis purpose. Moreover, the LC-Orbitrap Tribrid HRMS method could also benefit from its high mass resolution characteristic to eliminate potential environment interferents (e.g., taurodeoxycholate) and to quantify all PFSA isomers based on full-scan MS(1) chromatogram at a narrow MS window (5 part per million).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.chroma.2016.01.039

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 85

Metadata

Authors
Lin, Y., Liu, R., Hu, F., Liu, R., Ruan, T., & Jiang, G.
Venue
Journal of Chromatography A
Publisher
Elsevier BV
Published
2016-02
Volume
1435
Pages
66-74
ISSN
0021-9673 (ISSN-L)
OpenAlex
W2334573654
Cited by
85
References
12
FWCI
7.41
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simultaneous qualitative and quantitative analysis of fluoroalkyl sulfonates in riverine water by liquid chromatography coupled with Orbitrap high resolution mass spectrometry. https://app.cochat.ai/papers/10.1016/j.chroma.2016.01.039
The paper
Lin, Y., Liu, R., Hu, F., Liu, R., Ruan, T., & Jiang, G. (2016). Simultaneous qualitative and quantitative analysis of fluoroalkyl sulfonates in riverine water by liquid chromatography coupled with Orbitrap high resolution mass spectrometry. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2016.01.039

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.