Droplet digital PCR improves urinary exosomal miRNA detection compared to real-time PCR
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
OBJECT Quantification of urinary miRNAs can be challenging especially for low abundance miRNAs. We aimed to optimize the quantification of urinary exosomal miRNAs and compare the performance efficiency between droplet digital PCR (ddPCR) and real-time quantitative PCR (qPCR). METHODS We optimized a number of parameters for ddPCR such as annealing temperatures, annealing time and PCR cycle number. We also compared the performance of ddPCR and qPCR. RESULTS By comparing the fluorescence amplification separation, the optimal annealing temperature was 59 °C, optimal annealing time was 60s and optimal cycle number was 45 for measuring urinary exosomal miRNAs. ddPCR had much higher technical sensitivity compared to qPCR. The minimal detectable concentration of miR-29a was <50 copies/μL by ddPCR compared to 6473 copies/μL for qPCR. Also, ddPCR generated more consistent results for serially diluted samples compared to qPCR. ddPCR generated smaller within-run variations than qPCR though this did not reach statistical significance. It also resulted in better reproducibility with smaller between-run variations. CONCLUSIONS Optimization of urinary exosomal miRNA ddPCR assay is dependent on assessing key variables including experimental annealing temperature and time as well as the number of PCR cycles. ddPCR has a higher sensitivity, reproducibility, and accuracy in comparison to qPCR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-throughput droplet digital PCR system for absolute quantitation of DNA copy number
Hindson, B. J., Ness, K. D., Masquelier, D. A., Belgrader, P., Heredia, N. J., Makarewicz, A. J., Bright, I. J., Lucero, M. Y., Hiddessen, A. L., Legler, T. C., et al. (2011) · Analytical Chemistry · doi:10.1021/ac202028g · Cited by 2,792
Absolute quantification by droplet digital PCR versus analog real-time PCR
Hindson, C. M., Chevillet, J. R., Briggs, H. A., Gallichotte, E. N., Ruf, I. K., Hindson, B. J., Vessella, R. L., & Tewari, M. (2013) · Nature Methods · doi:10.1038/nmeth.2633 · Cited by 1,488
Evaluation of a Droplet Digital Polymerase Chain Reaction Format for DNA Copy Number Quantification
Pinheiro, L. B., Coleman, V. A., Hindson, C. M., Herrmann, J., Hindson, B. J., Bhat, S., & Emslie, K. R. (2012) · Analytical Chemistry · doi:10.1021/ac202578x · Cited by 1,055
Kogure, T., Yan, I. K., Lin, W.-L., & Patel, T. (2013) · Genes & Cancer · doi:10.1177/1947601913499020 · Cited by 303
Urine miR-21-5p as a potential non-invasive biomarker for gastric cancer
Kao, H.-W., Pan, C.-Y., Lai, C.-H., Wu, C.-W., Fang, W.-L., Huang, K.-H., & Lin, W.-C. (2017) · Oncotarget · doi:10.18632/oncotarget.16916 · Cited by 63
Cited by
Welsh, J. A., Goberdhan, D. C. I., O'Driscoll, L., Buzas, E. I., Blenkiron, C., Bussolati, B., Cai, H., Di Vizio, D., Driedonks, T. A. P., Erdbrügger, U., et al. (2024) · Journal of Extracellular Vesicles · doi:10.1002/jev2.12404 · Cited by 4,663
Exosomes as a new frontier of cancer liquid biopsy
Yu, D., Li, Y., Wang, M., Gu, J., Xu, W., Cai, H., Fang, X., & Zhang, X. (2022) · Molecular Cancer · doi:10.1186/s12943-022-01509-9 · Cited by 855
Exosome Processing and Characterization Approaches for Research and Technology Development
Lai, J. J., Chau, Z. L., Chen, S., Hill, J. J., Korpany, K. V., Liang, N., Lin, L., Lin, Y., Liu, J. K., Liu, Y., et al. (2022) · Advanced Science · doi:10.1002/advs.202103222 · Cited by 623
Advances in multiplexed techniques for the detection and quantification of microRNAs
Jet, T., Gines, G., Rondelez, Y., & Taly, V. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00609b · Cited by 453
Yang, L., Patel, K. D., Rathnam, C., Thangam, R., Hou, Y., Kang, H., & Lee, K. (2022) · Small · doi:10.1002/smll.202104783 · Cited by 81
Metadata
- Authors
- Wang, C., Ding, Q., Plant, P., Basheer, M., Yang, C., Tawedrous, E., Krizova, A., Boulos, C., Farag, M., Cheng, Y., & Yousef, G. M.
- Venue
- Clinical Biochemistry
- Publisher
- Elsevier BV
- Published
- 2019-05
- Volume
- 67
- Pages
- 54-59
- ISSN
- 0009-9120 (ISSN-L)
- OpenAlex
- W2924494780
- Cited by
- 105
- References
- 5
- FWCI
- 3.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Droplet digital PCR improves urinary exosomal miRNA detection compared to real-time PCR. https://app.cochat.ai/papers/10.1016/j.clinbiochem.2019.03.008
- The paper
- Wang, C., Ding, Q., Plant, P., Basheer, M., Yang, C., Tawedrous, E., Krizova, A., Boulos, C., Farag, M., Cheng, Y., & Yousef, G. M. (2019). Droplet digital PCR improves urinary exosomal miRNA detection compared to real-time PCR. Clinical Biochemistry. https://doi.org/10.1016/j.clinbiochem.2019.03.008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.