The DOI matches its Crossref record; 75 of the 75 references it cites were found in a registry or an index.
A review on five key sensors for monitoring of concrete structures
Abstract
A multitude of structural health monitoring options are currently being investigated to address the reliability of concrete infrastructures at different stages of their service life. This review presents the recent achievements in the field of sensors developed for monitoring the health of concrete infrastructures. The focus of this review is on sensors developed for monitoring parameters including temperature, humidity, pH, corrosion rate, and stress/strain and the sensors particularly fabricated based on fiber optic, Bragg grating, piezoelectric, electrochemical, wireless and self-sensing technologies. Several examples of developed concrete monitoring sensors (from laboratory concepts to commercialized products) together with their various benefits and drawbacks as well as open research problems will be discussed in this paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fiber Bragg grating technology fundamentals and overview
Hill, K. O., & Meltz, G. (1997) · Journal of Lightwave Technology · doi:10.1109/50.618320 · Cited by 3,060
Moisture movement in porous materials under temperature gradients
(1957) · Eos, Transactions American Geophysical Union · doi:10.1029/tr038i002p00222 · Cited by 2,398
Photosensitivity in optical fiber waveguides: Application to reflection filter fabrication
Hill, K. O., Fujii, Y., Johnson, D. C., & Kawasaki, B. S. (1978) · Applied Physics Letters · doi:10.1063/1.89881 · Cited by 2,250
Formation of Bragg gratings in optical fibers by a transverse holographic method
Meltz, G., Morey, W. W., & Glenn, W. H. (1989) · Optics Letters · doi:10.1364/ol.14.000823 · Cited by 1,808
Review of the present status of optical fiber sensors
Lee, B. (2003) · Optical Fiber Technology · doi:10.1016/s1068-5200(02)00527-8 · Cited by 1,736
A Summary Review of Wireless Sensors and Sensor Networks for Structural Health Monitoring
Lynch, J. P. (2006) · The Shock and Vibration Digest · doi:10.1177/0583102406061499 · Cited by 1,533
A review of structural health monitoring literature 1996-2001
Farrar, C. R., Czarnecki, J. J., Hoon Sohn, A., & Hemez, F. (2002) · Cited by 1,496
Structural Health Monitoring with Piezoelectric Wafer Active Sensors
(2014) · Elsevier eBooks · doi:10.1016/c2013-0-00155-7 · Cited by 1,398
Humidity Sensors Principle, Mechanism, and Fabrication Technologies: A Comprehensive Review
Farahani, H., Wagiran, R., & Hamidon, M. (2014) · Sensors · doi:10.3390/s140507881 · Cited by 1,286
Crack classification in concrete based on acoustic emission
Ohno, K., & Ohtsu, M. (2010) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2010.05.004 · Cited by 1,260
(2008) · Springer eBooks · doi:10.1007/978-3-540-69972-9 · Cited by 1,213
Kocak, G., Tuncer, C., & Bütün, V. (2017) · Polymer Chemistry · doi:10.1039/c6py01872f · Cited by 1,189
Structural health monitoring of civil infrastructure
Brownjohn, J. M. W. (2007) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2006.1925 · Cited by 998
Corrosion of Steel in Concrete: Understanding, investigation and repair
Broomfield, J. P. (1996) · Thammasat University Digital Collections · Cited by 904
High-Sensitivity Humidity Sensor Based on a Single SnO2 Nanowire
Kuang, Q., Lao, C., Wang, Z. L., Xie, Z., & Zheng, L. (2007) · Journal of the American Chemical Society · doi:10.1021/ja070788m · Cited by 892
Fiber Optic Sensors in Structural Health Monitoring
Lopez-Higuera, J. M., Rodriguez Cobo, L., Quintela Incera, A., & Cobo, A. (2011) · Journal of Lightwave Technology · doi:10.1109/jlt.2011.2106479 · Cited by 783
Encyclopedia of Structural Health Monitoring
(2009) · Wiley eBooks · doi:10.1002/9780470061626 · Cited by 778
A Review of Self‐Healing Concrete for Damage Management of Structures
De Belie, N., Gruyaert, E., Al‐Tabbaa, A., Antonaci, P., Baera, C., Bajare, D., Darquennes, A., Davies, R., Ferrara, L., Jefferson, T., et al. (2018) · Advanced Materials Interfaces · doi:10.1002/admi.201800074 · Cited by 774
Humidity sensors: Principles and applications
Yamazoe, N., & Shimizu, Y. (1986) · Sensors and Actuators · doi:10.1016/0250-6874(86)80055-5 · Cited by 618
Expression and analysis of pore fluids from hardened cement pastes and mortars
Barneyback, R. S., & Diamond, S. (1981) · Cement and Concrete Research · doi:10.1016/0008-8846(81)90069-7 · Cited by 604
Corrosion Monitoring of Reinforced Concrete Structures – A Review
Song, H.-W., & Saraswathy, V. (2007) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)17049-0 · Cited by 595
Structural Health Monitoring in mainland China: Review and Future Trends
Ou, J., & Li, H. (2010) · Structural Health Monitoring · doi:10.1177/1475921710365269 · Cited by 525
Advances in Lead-Free Piezoelectric Materials for Sensors and Actuators
Aksel, E., & Jones, J. L. (2010) · Sensors · doi:10.3390/s100301935 · Cited by 508
Fibre Optic Methods for Structural Health Monitoring
Glišić, B., & Inaudi, D. (2007) · Wiley eBooks · doi:10.1002/9780470517819 · Cited by 490
Structural Health Monitoring Using Wireless Sensor Networks: A Comprehensive Survey
Noel, A. B., Abdaoui, A., Elfouly, T., Ahmed, M. H., Badawy, A., & Shehata, M. S. (2017) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2017.2691551 · Cited by 489
Smart aggregates: multi-functional sensors for concrete structures—a tutorial and a review
Song, G., Gu, H., & Mo, Y.-L. (2008) · Smart Materials and Structures · doi:10.1088/0964-1726/17/3/033001 · Cited by 444
Climate change impact and risks of concrete infrastructure deterioration
Stewart, M. G., Wang, X., & Nguyen, M. N. (2011) · Engineering Structures · doi:10.1016/j.engstruct.2011.01.010 · Cited by 444
A self-sensing carbon nanotube/cement composite for traffic monitoring
Han, B., Yu, X., & Kwon, E. (2009) · Nanotechnology · doi:10.1088/0957-4484/20/44/445501 · Cited by 431
Structural health monitoring: Closing the gap between research and industrial deployment
Cawley, P. (2018) · Structural Health Monitoring · doi:10.1177/1475921717750047 · Cited by 423
Zinc oxide nanorod and nanowire for humidity sensor
Zhang, Y., Yu, K., Jiang, D., Zhu, Z., Geng, H., & Luo, L. (2005) · Applied Surface Science · doi:10.1016/j.apsusc.2004.08.013 · Cited by 420
Electronic semiconducting oxides as pH sensors
Fog, A., & Buck, R. P. (1984) · Sensors and Actuators · doi:10.1016/0250-6874(84)80004-9 · Cited by 401
Ramakrishnan, M., Rajan, G., Semenova, Y., & Farrell, G. (2016) · Sensors · doi:10.3390/s16010099 · Cited by 382
Handoo, S. K., Agarwal, S., & Agarwal, S. K. (2002) · Cement and Concrete Research · doi:10.1016/s0008-8846(01)00736-0 · Cited by 366
Plusquellec, G., Geiker, M. R., Lindgård, J., Duchesne, J., Fournier, B., & De Weerdt, K. (2017) · Cement and Concrete Research · doi:10.1016/j.cemconres.2017.03.002 · Cited by 354
Optical Fiber Sensor Technology
(1998) · Springer eBooks · doi:10.1007/978-1-4615-5787-6 · Cited by 315
Concrete early-age strength monitoring using embedded piezoelectric transducers
Gu, H., Song, G., Dhonde, H., Mo, Y. L., & Yan, S. (2006) · Smart Materials and Structures · doi:10.1088/0964-1726/15/6/038 · Cited by 312
Effect of global climatic change on carbonation progress of concrete
Yoon, I.-S., Çopuroğlu, O., & Park, K.-B. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.05.028 · Cited by 286
Alwis, L., Sun, T., & Grattan, K. T. V. (2013) · Measurement · doi:10.1016/j.measurement.2013.07.030 · Cited by 276
Development of fiber Bragg grating sensors for monitoring civil infrastructure
Moyo, P., Brownjohn, J. M. W., Suresh, R., & Tjin, S. C. (2005) · Engineering Structures · doi:10.1016/j.engstruct.2005.04.023 · Cited by 273
Methods for measuring pH in concrete: A review
Behnood, A., Van Tittelboom, K., & De Belie, N. (2016) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2015.12.032 · Cited by 262
Thermal Stresses and Temperature Control of Mass Concrete
(2014) · Elsevier eBooks · doi:10.1016/c2012-0-06038-3 · Cited by 262
Introduction to Structural Health Monitoring
Balageas, D. (2006) · Structural Health Monitoring · doi:10.1002/9780470612071.ch1 · Cited by 222
Ihn, J.-B., & Chang, F.-K. (2004) · Smart Materials and Structures · doi:10.1088/0964-1726/13/3/021 · Cited by 215
The pH measurement of concrete and smoothing mortar using a concrete powder suspension
Räsänen, V., & Penttala, V. (2003) · Cement and Concrete Research · doi:10.1016/j.cemconres.2003.09.017 · Cited by 191
Sensor systems for use in reinforced concrete structures
McCarter, W. J., & Vennesland, Ø. (2004) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2004.03.008 · Cited by 182
Self-monitoring, pseudo-ductile, hybrid FRP reinforcement rods for concrete applications
Bakis, C. E., Nanni, A., Terosky, J., & Koehler, S. W. (2001) · Composites Science and Technology · doi:10.1016/s0266-3538(00)00184-6 · Cited by 174
Gardner, D., Lark, R., Jefferson, T., & Davies, R. (2018) · Case Studies in Construction Materials · doi:10.1016/j.cscm.2018.02.002 · Cited by 173
Wireless sensor networks for temperature and humidity monitoring within concrete structures
Barroca, N., Borges, L. M., Velez, F. J. D. S., Monteiro, F., Górski, M., & Castro-Gomes, J. P. (2013) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2012.11.087 · Cited by 156
Smart Sensing Technologies for Structural Health Monitoring of Civil Engineering Structures
Sun, M., Staszewski, W. J., & Swamy, R. N. (2010) · Advances in Civil Engineering · doi:10.1155/2010/724962 · Cited by 156
Concrete deterioration: causes, diagnosis, and minimising risk
Hobbs, D. W. (2001) · International Materials Reviews · doi:10.1179/095066001101528420 · Cited by 153
Norris, A., Saafi, M., & Romine, P. (2006) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2006.05.047 · Cited by 145
Humidity Sensing with Ultrathin LTA-Type Molecular Sieve Films Grown on Piezoelectric Devices
Mintova, S., Mo, S., & Bein, T. (2001) · Chemistry of Materials · doi:10.1021/cm000671w · Cited by 141
Self-sensing concrete enabled by nano-engineered cement-aggregate interfaces
Gupta, S., Gonzalez, J., & Loh, K. J. (2016) · Structural Health Monitoring · doi:10.1177/1475921716643867 · Cited by 141
A passive wireless integrated humidity sensor
Harpster, T. J., Stark, B. H., & Najafi, K. (2002) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(01)00720-8 · Cited by 120
A review on smart self-sensing composite materials for civil engineering applications
Rana, S., Subramani, P., Fangueiro, R. M. E. S., & Correia, A. G. (2016) · AIMS Materials Science · doi:10.3934/matersci.2016.2.357 · Cited by 117
Li, H., XIAO, H., & OU, J. (2008) · Composites Science and Technology · doi:10.1016/j.compscitech.2008.03.007 · Cited by 103
Strain monitoring in composite-strengthened concrete structures using optical fibre sensors
Lau, K.-T., Chan, C. C., Zhou, L., & Jin, W. (2001) · Composites Part B Engineering · doi:10.1016/s1359-8368(00)00044-5 · Cited by 89
State-of-the-art in the applications of fiber-optic sensors to cementitious composites
Ansari, F. (1997) · Cement and Concrete Composites · doi:10.1016/s0958-9465(96)00038-8 · Cited by 89
Cyr, M., Rivard, P., Labrecque, F., & Daidié, A. (2008) · Journal of the American Ceramic Society · doi:10.1111/j.1551-2916.2008.02525.x · Cited by 86
Duchesne, J., & Bérubé, M. A. (1994) · Cement and Concrete Research · doi:10.1016/0008-8846(94)90132-5 · Cited by 85
Embeddable Ag/AgCl sensors for in-situ monitoring chloride contents in concrete
Climent, M. Á., Viqueira-Pérez, E., & López-Atalaya, M. (1996) · Cement and Concrete Research · doi:10.1016/0008-8846(96)00104-4 · Cited by 83
Online monitoring of cracking in concrete structures using embedded piezoelectric transducers
Dumoulin, C., Karaiskos, G., Sener, J.-Y., & Deraemaeker, A. (2014) · Smart Materials and Structures · doi:10.1088/0964-1726/23/11/115016 · Cited by 77
Liu, X., Niu, D., Li, X., Lv, Y., & Fu, Q. (2018) · Applied Sciences · doi:10.3390/app8010128 · Cited by 63
Zou, X., Chao, A., Tian, Y., Wu, N., Zhang, H., Yu, T., & Wang, X. (2012) · Measurement · doi:10.1016/j.measurement.2012.01.034 · Cited by 60
Maruya, T., Hsu, K., Takeda, H., & Tangtermsirikul, S. (2003) · Journal of Advanced Concrete Technology · doi:10.3151/jact.1.147 · Cited by 56
Sewerage tunnel leakage detection using a fibre optic moisture-detecting sensor system
Bremer, K., Meinhardt‐Wollweber, M., Thiel, T., et al. (2014) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2014.09.018 · Cited by 54
Ožbolt, J., Oršanić, F., & Balabanić, G. (2016) · Structure and Infrastructure Engineering · doi:10.1080/15732479.2016.1198400 · Cited by 48
Chemical sulfide oxidation of wastewater - effects of pH and temperature
Nielsen, A. H., Vollertsen, J., & Hvitved‐Jacobsen, T. (2004) · Water Science & Technology · doi:10.2166/wst.2004.0258 · Cited by 44
Hydrogel-coated fiber Bragg grating sensor for pH monitoring
Pabbisetti, V. N. K., & Madhuvarasu, S. S. (2016) · Optical Engineering · doi:10.1117/1.oe.55.6.066112 · Cited by 40
Monitoring pH in corrosion engineering by means of thermally produced iridium oxide electrodes
Femenias, Y. S., Angst, U., & Elsener, B. (2017) · Materials and Corrosion · doi:10.1002/maco.201709715 · Cited by 38
A review of sample preparation and its influence on pH determination in concrete samples
Manso, S., & Aguado, A. (2017) · Materiales de Construcción · doi:10.3989/mc.2017.08515 · Cited by 33
Monitoring of the absolute water content in porous materials based on embedded humidity sensors
Strangfeld, C., & Kruschwitz, S. (2018) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2018.05.044 · Cited by 33
Sun, X. (2015) · The University of Queensland · doi:10.14264/uql.2015.1093 · Cited by 19
Fundamentals of Thermal Sensors
Huynh, T. (2015) · Springer eBooks · doi:10.1007/978-1-4939-2581-0_2 · Cited by 18
Wireless Piezoelectric Sensor Systems for Defect Detection and Localization
Dai, X., Gao, S., Pan, K., Zhu, J., & Rashvand, H. F. (2017) · Wiley eBooks · doi:10.1002/9781119126492.ch10 · Cited by 6
Cited by
Mishra, M., Lourenço, P. B., & Ramana, G. V. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2021.103954 · Cited by 479
Rodrigues, R., Gaboreau, S., Gance, J., Ignatiadis, I., & Betelu, S. (2021) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2020.121240 · Cited by 410
Computer vision framework for crack detection of civil infrastructure—A review
Ai, D., Jiang, G., Lam, S.-K., He, P., & Li, C. (2023) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2022.105478 · Cited by 297
Sivasuriyan, A., Vijayan, D. S., LeemaRose, A., Revathy, J., Gayathri Monicka, S., Adithya, U. R., & Jebasingh Daniel, J. (2021) · Advances in Materials Science and Engineering · doi:10.1155/2021/2615029 · Cited by 29
Retracted
Metadata
- Authors
- Taheri, S.
- Venue
- Construction and Building Materials
- Publisher
- Elsevier BV
- Published
- 2019-04
- Volume
- 204
- Pages
- 492-509
- ISSN
- 0950-0618 (ISSN-L)
- OpenAlex
- W2913988572
- Cited by
- 311
- References
- 75
- FWCI
- 8.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.