The DOI matches its Crossref record.
A database of metallic materials emissivities and absorptivities for cryogenics
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Even for materials of identical composition, preparation methods and surface structure can lead to substantial variations in emissivity.
“These results highlight that even for materials of identical composition, preparation methods and surface structure can lead to substantial variations in emissivity.”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [30]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 22
- Frolec, 2017, Low temperature thermal radiative properties of gold coated metals, Int J Refrig, 82, 51, 10.1016/j.ijrefrig.2017.06.034 · DOI
- Tuttle, 2016, Cryogenic thermal absorptance measurements on small-diameter stainless steel tubing, Cryogenics, 74, 166, 10.1016/j.cryogenics.2015.09.003 · DOI
- Anderson, 1971, Measurement and control of thermal radiation below 6 K, J Low Temp Phys, 5, 591, 10.1007/BF00628187 · DOI · Paper page
- Woods, 2014, Emissivity of silver and stainless steel from 80 K to 300 K: application to ITER thermal shields, Cryogenics, 60, 44, 10.1016/j.cryogenics.2014.01.002 · DOI · Paper page
- Tuttle, 2014, The area-density-dependence of Ball IR Black’s low-temperature emissivity, Cryogenics, 64, 240, 10.1016/j.cryogenics.2014.04.024 · DOI
- Franck, 2012, Cryogenic emissivity properties of Ball Infrared Black, AIP Conf Proc, 1434, 1497, 10.1063/1.4707078 · DOI
- Giulietti, 1981, Emissivity and absorptivity measurements on some high-purity metals at low-temperature, J Phys D Appl Phys, 14, 877, 10.1088/0022-3727/14/5/019 · DOI
- Estalote, 1977, Low-temperature emissivities of copper and aluminum, J Opt Soc Am, 67, 39, 10.1364/JOSA.67.000039 · DOI
- Tsujimoto, 1982, Thermal radiative properties of some cryogenic materials, Cryogenics, 22, 591, 10.1016/0011-2275(82)90007-8 · DOI
- Ruccia FE, Hinckley RB. The surface emittance of vacuum-metallized polyester film. Advances in Cryogenic Engineering. Boston, MA. 1967. p. 300–7. https://doi.org/10.1007/978-1-4757-0489-1_31. · DOI
- Hawks KH, Cottingham WB. Total normal emittances of some real surfaces at cryogenic temperatures. Advances in Cryogenic Engineering. Boston, MA. 1971. p. 467–74. https://doi.org/10.1007/978-1-4757-0244-6_57. · DOI
- Ramanathan, 1977, Total hemispherical emissivities of copper, aluminum, and silver, Appl Opt, 16, 2810, 10.1364/AO.16.002810 · DOI · Paper page
- Jahromi, 2017, Iop. Cryogenic thermal emittance measurements on small-diameter stainless steel tubing, IOP Conf Ser: Mater Sci Eng, 10.1088/1757-899X/278/1/012002 · DOI
- Musilova, 2005, Low temperature radiative properties of materials used in cryogenics, Cryogenics, 45, 529, 10.1016/j.cryogenics.2004.11.010 · DOI · Paper page
- Kralik, 2016, Method for measurement of emissivity and absorptivity of highly reflective surfaces from 20 K to room temperatures, Metrologia, 53, 743, 10.1088/0026-1394/53/2/743 · DOI · Paper page
- Musilova, 2007, Effect of different treatments of copper surface on its total hemispherical absorptivity bellow 77 K, Cryogenics, 47, 257, 10.1016/j.cryogenics.2007.02.001 · DOI · Paper page
- Hanzelka, 2008, Thermal radiative properties of a DLC coating, Cryogenics, 48, 455, 10.1016/j.cryogenics.2008.03.021 · DOI
- Hanzelka, 2010, Influence of condensed water on heat radiation absorptivity at cryogenic temperatures, Cryogenics, 50, 331, 10.1016/j.cryogenics.2010.01.007 · DOI
- Domoto GA, Boehm RF, Tien CL. Predictions of the total emissivity of metals at cryogenic temperatures. Advances in Cryogenic Engineering. Boston, MA. 1969. p. 230–9. https://doi.org/10.1007/978-1-4757-0549-2_29. · DOI
- Ramanathan KG. Infra-Red Absorption by Metals at Low Temperatures. Proceedings of the Physical Society Section A 1952;65:532. · DOI
- Kim, 2014, Emissivity measurement of coated copper and aluminum samples at 80 K, AIP Conf Proc, 1573, 500, 10.1063/1.4860742 · DOI
- Domoto, 1970, Experimental investigation of radiative transfer between metallic surfaces at cryogenic temperatures, J Heat Transfer, 92, 412, 10.1115/1.3449677 · DOI
Cited by
Sorted by citations
Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review
Li, B., & Shen, F. (2026) · Cryo · doi:10.3390/cryo2010004 · Cited by 1
Metadata
- Authors
- Frolec, J., Králík, T., Musilová, V., Hanzelka, P., Srnka, A., & Jelínek, J.
- ORCID
- Hanzelka, Pavel
- Venue
- Cryogenics
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 97
- Pages
- 85-99
- ISSN
- 0011-2275
- Cited by
- 36
- References
- 0
- Language
- en
- Funders
- Ministry of Education, Youth and Sports of the Czech Republic (LO1212)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›