The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Development of phase-contrast X-ray imaging techniques and potential medical applications
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Henke, B. L., Gullikson, E. M., & Davis, J. C. (1993) · Atomic Data and Nuclear Data Tables · doi:10.1006/adnd.1993.1013 · Cited by 6,285
Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources
Pfeiffer, F., Weitkamp, T., Bunk, O., & David, C. (2006) · Nature Physics · doi:10.1038/nphys265 · Cited by 1,855
Phase-contrast imaging using polychromatic hard X-rays
Wilkins, S. W., Gureyev, T. E., Gao, D., Pogany, A., & Stevenson, A. W. (1996) · Nature · doi:10.1038/384335a0 · Cited by 1,766
Snigirev, A., Snigireva, I., Kohn, V., Kuznetsov, S., & Schelokov, I. (1995) · Review of Scientific Instruments · doi:10.1063/1.1146073 · Cited by 1,493
X-ray phase imaging with a grating interferometer
Weitkamp, T., Diaz, A., David, C., Pfeiffer, F., Stampanoni, M., Cloetens, P., & Ziegler, E. (2005) · Optics Express · doi:10.1364/opex.13.006296 · Cited by 1,211
Goldring, M. B., & Goldring, S. R. (2007) · Journal of Cellular Physiology · doi:10.1002/jcp.21258 · Cited by 1,179
Diffraction enhanced x-ray imaging
Chapman, D., Thomlinson, W., Johnston, R. E., Washburn, D., Pisano, E., Gmür, N., Zhong, Z., Menk, R., Arfelli, F., & Sayers, D. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/11/001 · Cited by 1,098
Cloetens, P., Ludwig, W., Baruchel, J., Van Dyck, D., Van Landuyt, J., Guigay, J. P., & Schlenker, M. (1999) · Applied Physics Letters · doi:10.1063/1.125225 · Cited by 1,078
Phase contrast, a new method for the microscopic observation of transparent objects
Zernike, F. (1942) · Physica · doi:10.1016/s0031-8914(42)80035-x · Cited by 1,068 · cited 1×
“In fact, phase-contrast methods were first introduced into optical microscopy by Zernike in 1930s [4,5].”
MethodBonse, U., & Hart, M. (1965) · Applied Physics Letters · doi:10.1063/1.1754212 · Cited by 1,057
Cited by
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Metal Halide Perovskites for X-ray Imaging Scintillators and Detectors
Zhou, Y., Chen, J., Bakr, O. M., & Mohammed, O. F. (2021) · ACS Energy Letters · doi:10.1021/acsenergylett.0c02430 · Cited by 891
X-ray phase-contrast imaging: from pre-clinical applications towards clinics
Bravin, A., Coan, P., & Suortti, P. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/1/r1 · Cited by 846
Scintillating Nanoparticles as Energy Mediators for Enhanced Photodynamic Therapy
Kamkaew, A., Chen, F., Zhan, Y., Majewski, R. L., & Cai, W. (2016) · ACS Nano · doi:10.1021/acsnano.6b01401 · Cited by 355
Stampanoni, M., Wang, Z., Thüring, T., David, C., Roessl, E., Trippel, M., Kubik-Huch, R. A., Singer, G., Hohl, M. K., & Hauser, N. (2011) · Investigative Radiology · doi:10.1097/rli.0b013e31822a585f · Cited by 254
Metadata
- Authors
- Zhou, S.-A., & Brahme, A.
- Venue
- Physica Medica
- Publisher
- Elsevier BV
- Published
- 2008-09
- Volume
- 24
- Issue
- 3
- Pages
- 129-148
- ISSN
- 1120-1797 (ISSN-L)
- OpenAlex
- W2163177684
- Cited by
- 268
- References
- 44
- FWCI
- 10.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.