CoChat

Experimental study on the melted frost influence on the metal energy storage during an air source heat pump defrosting

SONG, Mengjie, MAO, Ning · 2020 · Energy and Buildings
Cited by 26

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

When an air source heat pump works at reverse cycle defrosting mode, the metal temperature of its indoor coil decreases and that of outdoor coil increases. The energy storage of two coils’ metal at heating mode would influence the system defrosting efficiency. For a vertically installed outdoor coil having multiple circuits, meanwhile, the melted frost downwards flowing from upside circuit(s) also delay the defrosting process of downside circuit(s). To quantitatively evaluate the influence from two parameters, metal energy storage and melted frost, four experimental cases were designed and carried out in this study, based on a specially made three-circuit outdoor coil. Three circuits are working at the frosting mode, while two and three are used at the defrosting mode in four cases. As concluded, the melted frost influence on defrosting efficiency and metal energy storage effect would be increased from 4.87% to 10.45% and from 0.77% to 1.49%, respectively, after the outdoor coil changed from two- to three-working circuit. Outcomes of this study are meaningful for the structure optimization and energy saving of air source heat pump units at defrosting mode.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.enbuild.2020.109809

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

Metadata

Authors
SONG, M., & MAO, N.
Venue
Energy and Buildings
Publisher
Elsevier BV
Published
2020-05
Volume
214
Pages
109809
ISSN
0378-7788 (ISSN-L)
OpenAlex
W3004574801
Cited by
26
References
12
FWCI
2.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.