Effects of inclination on the frosting process on cold surface of copper heat exchanger
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
During the frost layer growth stage of a frost formation process, as the inclination angle of a flat plate increases, the average frost thickness increases but the average frost density decreases.
“During the frost layer growth stage of a frost formation process, the average frost thickness was increased, but the average frost density decreased as the inclination angle of a flat plate was increased.”
From Frosting mechanism and behaviors on surfaces with simple geometries: A state-of-the-art literature review (2022) · cites this paper as [107]
During the early stage of a frost formation process, as the inclination angle of the flat plate increases, the number of water droplets increases but the average radius of water droplets decreases.
“During the early stage of a frost formation process, the number of water droplets was increased, but the average radius of water droplets decreased as the inclination angle of the flat plate increased.”
From Frosting mechanism and behaviors on surfaces with simple geometries: A state-of-the-art literature review (2022) · cites this paper as [107]
Cites
Experimental study of frost accumulation on fan-supplied tube-fin evaporators
da Silva, D. L., Hermes, C. J. L., & Melo, C. (2011) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2010.11.006 · Cited by 118 · see citing works
Huang, L., Liu, Z., Liu, Y., Gou, Y., & Wang, J. (2009) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2009.06.002 · Cited by 108 · see citing works
Modeling for predicting frosting behavior of a fin–tube heat exchanger
Yang, D.-K., Lee, K.-S., & Song, S. (2006) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2005.09.022 · Cited by 94 · see citing works
<i>Review Article:</i> A Critical Review of Properties and Models for Frost Formation Analysis
Iragorry, J., Tao, Y.-X., & Jia, S. (2004) · HVAC&R Research · doi:10.1080/10789669.2004.10391111 · Cited by 89 · see citing works
Zhang, L., Jiang, Y., Dong, J., Yao, Y., & Deng, S. (2019) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2018.09.016 · Cited by 65 · see citing works
Moallem, E., Padhmanabhan, S., Cremaschi, L., & Fisher, D. E. (2012) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2011.08.010 · Cited by 61 · see citing works
Frosting behaviors and thermal performance of louvered fins with unequal louver pitch
Park, J.-S., Kim, D. R., & Lee, K.-S. (2016) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2015.12.042 · Cited by 51 · see citing works
Liu, X., Yu, J., & Yan, G. (2020) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2019.114634 · Cited by 47 · see citing works
Kim, K., Kim, D. R., & Lee, K.-S. (2013) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2013.05.027 · Cited by 46 · see citing works
Effect of some geometric parameters on performance of PF2 heat exchangers in periodic frosting
Zhang, P., & Hrnjak, P. S. (2010) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2009.11.004 · Cited by 38 · see citing works
Characteristics of frost formation on two-dimensional fins and its empirical correlations
Kim, K., Kim, J.-S., & Lee, K.-S. (2010) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2010.02.043 · Cited by 25 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Zhang, L., Song, M., Deng, S., Shen, J., & Dang, C. (2022) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2022.118984 · Cited by 83 · see citing works
Li, K., Xia, D., Luo, S., Zhao, Y., Tu, R., Zhou, X., Zhang, H., & Su, L. (2022) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2021.117766 · Cited by 40 · see citing works
Su, W., Ma, D., Jin, X., Liu, Z., & Zhao, D. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.122089 · Cited by 15 · see citing works
- Authors
- Chen, A., Meng, Y., Liu, B., Li, Y., & Miao, Z.
- Affiliations
- Tianjin University of Commerce (CN)
- Corresponding author
- Liu, Bin
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 231
- Pages
- 110628
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W3106774131
- Cited by
- 14
- References
- 11
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 1 · 2023: 4 · 2022: 2 · 2021: 3
- FWCI
- 1.35
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Energy and Buildings (publishedVersion)
- Funders
- Tianjin Natural Science Foundation (18JCQNJC84600)
- Foundation of Tianjin Educational Committee (2017KJ177)
- Program for Innovation Research Team of Tianjin Colleges and Universities (TD13-5088)
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Keywords
- frost formation, tilt angle, inclined surfaces, copper heat exchanger, droplet growth, droplet coalescence, heat and mass transfer, phase transitions, drag force, frost protection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›