Cited by 46Refrigeration and Air Conditioning TechnologiesHeat Transfer and OptimizationIcing and De-icing Technologies

Local frosting behavior of a plated-fin and tube heat exchanger according to the refrigerant flow direction and surface treatment

Kim, Kyoungmin, Kim, Dong Rip, Lee, Kwan-Soo·2013·International Journal of Heat and Mass Transfer

Integrity signals

Registry

Crossref · 10.1016/j.ijheatmasstransfer.2013.05.027

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Kim, K., Kim, D. R., & Lee, K.-S.
Affiliations
Hanyang University (KR)
Corresponding author
Lee, Kwan-Soo
Venue
International Journal of Heat and Mass Transfer
Publisher
Elsevier BV
Published
2013-09
Volume
64
Pages
751-758
ISSN
0017-9310 (ISSN-L)
OpenAlex
W1992805403
Cited by
46
References
16
Citations by year
2026: 3 · 2025: 4 · 2024: 4 · 2023: 4 · 2022: 4 · 2021: 5 · 2020: 4 · 2019: 1 · 2018: 5 · 2017: 4 · 2016: 2 · 2015: 4 · 2014: 1 · 2013: 1
FWCI
3.54
Type
journal article
Language
en
Open access
closed
Locations
International Journal of Heat and Mass Transfer (publishedVersion)
Funders
Ministry of Knowledge Economy
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
Keywords
frost layer, plate fin-and-tube heat exchangers, heat pumps, countercurrent flow, parallel flow, hydrophilic surface modification, hydrophobic surface treatment, heat transfer rate, frost growth, air velocity, outdoor unit

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review