CoChat

Risk-informed optimization of the tuned mass-damper-inerter (TMDI) for the seismic protection of multi-storey building structures

Open access
Ruiz, R., Taflanidis, A.A., Giaralis, A., Lopez-Garcia, D. · 2018 · Engineering Structures
Cited by 133

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

The tuned mass-damper-inerter (TMDI) is a recently proposed passive vibration suppression device that couples the classical tuned mass-damper (TMD), comprising a secondary mass attached to the structure via a spring and dashpot, with an inerter. The latter is a two-terminal mechanical device developing a resisting force proportional to the relative acceleration of its terminals by the “inertance” constant. In a number of previous studies, optimally tuned TMDIs have been shown to outperform TMDs in mitigating earthquake-induced vibrations in building structures for the same pre-specified secondary mass. TMDI design in these studies involved simplified modeling assumptions, such as adopting a single performance objective and/or modeling seismic excitation as stationary stochastic process. This paper extends these efforts by examining a risk-informed TMDI optimization, adopting multiple objectives and using response history analysis and probabilistic life-cycle criteria to quantify performance. The first performance criterion, representing overall direct benefits, is the life-cycle cost of the system, composed of the upfront TMDI cost and the anticipated seismic losses over the lifetime of the structure. The second performance criterion, introducing risk-aversion attitudes into the design process, is the repair cost with a specific return period (i.e., probability of exceedance over the lifetime of the structure). The third performance criterion, accounting for practical constraints associated with the size of the inerter and its connection to the structure, is the inerter force with a specific return period. A particular variant of the design problem is also examined by combining the first and third performance criteria/objectives. A case study involving a 21-storey building constructed in Santiago, Chile shows that optimal TMDI configurations can accomplish simultaneous reduction of life-cycle and repair costs. However, these cost reductions come at the expense of increased inerter forces. It is further shown that connecting the inerter to lower floors provides considerable benefits across all examined performance criteria as the inerter is engaged in a more efficient way for the same inerter coefficient and attached mass ratios.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.engstruct.2018.08.074

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Research works printed but not linked: 39

  1. Kareem A. The next generation of tuned liquid dampers. Proc, First World Conference on Structural Control1994. p. 19–28.
  2. Tait, 2007, Effectiveness of a 2D TLD and its numerical modeling, J Struct Eng, 133, 251, 10.1061/(ASCE)0733-9445(2007)133:2(251) · doi:10.1061/(asce)0733-9445(2007)133:2(251
  3. Feng, 1995, Vibration control of tall buildings using mega subconfiguration, J Eng Mech, 121, 1082, 10.1061/(ASCE)0733-9399(1995)121:10(1082) · doi:10.1061/(asce)0733-9399(1995)121:10(1082 · Paper page
  4. Matta, 2011, Performance of tuned mass dampers against near-field earthquakes, Struct Eng Mech, 39, 621, 10.12989/sem.2011.39.5.621 · DOI · Paper page
  5. Reggio, 2015, Optimal energy-based seismic design of non-conventional Tuned Mass Damper (TMD) implemented via inter-story isolation, Earthq Eng Struct Dyn, 44, 1623, 10.1002/eqe.2548 · DOI · Paper page
  6. Lavan, 2017, Multi-objective optimal design of tuned mass dampers, Struct Control Health Monitor, 24, 10.1002/stc.2008 · DOI
  7. Ruiz, 2015, Life-cycle based design of mass dampers for the Chilean region and its application for the evaluation of the effectiveness of tuned liquid dampers with floating roof, Bull Earthq Eng, 14, 943, 10.1007/s10518-015-9860-9 · DOI
  8. Taflanidis, 2009, Life-cycle cost optimal design of passive dissipative devices, Struct Saf, 31, 508, 10.1016/j.strusafe.2009.06.010 · DOI
  9. Shin, 2014, Minimum failure cost-based energy dissipation system designs for buildings in three seismic regions Part II: Application to viscous dampers, Eng Struct
  10. Pollini, 2016, Towards realistic minimum-cost optimization of viscous fluid dampers for seismic retrofitting, Bull Earthq Eng, 14, 971, 10.1007/s10518-015-9844-9 · DOI
  11. Marian L, Giaralis A. Optimal design of inerter devices combined with TMDs for vibration control of buildings exposed to stochastic seismic excitations. In: 11th International Conference on Structural Safety and Reliability. New York, US2013. p. 1025–32. · DOI
  12. Watanabe Y, Ikago K, Inoue N, Kida H, Nakaminami S, Tanaka H et al. Full-scale dynamic tests and analytical verification of a force-restricted tuned viscous mass damper. In: 15th World Conference on Earthquake Engineering. Lisbon, Portugal 2012.
  13. Nakamura, 2014, Seismic response control using electromagnetic inertial mass dampers, Earthq Eng Struct Dyn, 43, 507, 10.1002/eqe.2355 · DOI · Paper page
  14. Giaralis, 2018, Optimal tuned mass-damper-inerter (TMDI) design for seismically excited MDOF structures with model uncertainties based on reliability criteria, Struct Control Health Monitor, 25, e2082, 10.1002/stc.2082 · DOI · Paper page
  15. Hwang, 2007, Rotational inertia dampers with toggle bracing for vibration control of a building structure, Eng Struct, 29, 1201, 10.1016/j.engstruct.2006.08.005 · DOI · Paper page
  16. Giaralis A, Marian L. Use of inerter devices for weight reduction of tuned mass-dampers for seismic protection of multi-story building: the Tuned Mass-Damper-Interter (TMDI). SPIE 9799, Active and Passive Smart Structures and Integrated Systems Las Vegas, Nevada 2016. p. doi: 10.1117/12.2219324. · DOI
  17. Ikago, 2012, Modal response characteristics of a multiple-degree-of-freedom structure incorporated with tuned viscous mass dampers, J Asian Architect Build Eng, 11, 375, 10.3130/jaabe.11.375 · DOI
  18. Krenk, 2016, Tuned resonant mass or inerter-based absorbers: unified calibration with quasi-dynamic flexibility and inertia correction, Proc Royal Soc A, 472, 20150718, 10.1098/rspa.2015.0718 · DOI · Paper page
  19. Wen, 2016, Design and evaluation of tuned inerter-based dampers for the seismic control of MDOF structures, J Struct Eng, 143, 04016207, 10.1061/(ASCE)ST.1943-541X.0001680 · DOI · Paper page
  20. Zhang, 2017, Optimal configurations for a linear vibration suppression device in a multi-storey building, Struct Control Health Monitor, 24, 10.1002/stc.1887 · DOI · Paper page
  21. Takewaki, 2012, Fundamental mechanism of earthquake response reduction in building structures with inertial dampers, Struct Control Health Monitor, 19, 590, 10.1002/stc.457 · DOI · Paper page
  22. Boroschek R, Contreras V. Strong ground motion form the 2010 Mw 8.8 Maule Chile earthquake and attenuation relations for Chilean subduction zone interface earthquakes. In: International Symposium on Engineering Lessons Learned from the 2011 Great East Japan earthquake. Tokyo, Japan 2012. · doi:10.1193/1.4000045
  23. Gidaris, 2018, Multiobjective design of supplemental seismic protective devices utilizing lifecycle performance criteria, J Struct Eng, ASCE, 144, 04017225, 10.1061/(ASCE)ST.1943-541X.0001969 · DOI
  24. Cha, 2014, Seismic risk mitigation of building structures: The role of risk aversion, Struct Saf, 40, 11, 10.1016/j.strusafe.2012.06.004 · DOI
  25. Haukaas, 2008, Unified reliability and design optimization for earthquake engineering, Probab Eng Mech, 23, 471, 10.1016/j.probengmech.2007.10.008 · doi:10.1016/j.probengmech.2007.10.008
  26. Massone, 2012, Seismic design and construction practices for RC structural wall buildings, Earthq Spectra, 28, S245, 10.1193/1.4000046 · doi:10.1193/1.4000046
  27. Marian, 2017, The tuned mass-damper-inerter for harmonic vibrations suppression, attached mass reduction, and energy harvesting, Smart Struct Syst
  28. Goulet, 2007, Evaluation of the seismic performance of code-conforming reinforced-concrete frame building-From seismic hazard to collapse safety and economic losses, Earthq Eng Struct Dyn, 36, 1973, 10.1002/eqe.694 · DOI · Paper page
  29. Porter, 2001, Assembly-based vulnerability of buildings and its use in performance evaluation, Earthq Spectra, 18, 291, 10.1193/1.1586176 · doi:10.1193/1.1586176
  30. Gidaris, 2015, Performance assessment and optimization of fluid viscous dampers through life-cycle cost criteria and comparison to alternative design approaches, Bull Earthq Eng, 13, 1003, 10.1007/s10518-014-9646-5 · DOI
  31. Zemp, 2011, Tall building vibration control using a TM-MR damper assembly: Experimental results and implementation, Earthq Eng Struct Dyn, 40, 257, 10.1002/eqe.1021 · doi:10.1002/eqe.1021
  32. Leyton, 2009, Preliminary re-evaluation of probabilistic seismic hazard assessment in Chile: from Arica to Taitao Peninsula, Adv Geosci, 22, 147, 10.5194/adgeo-22-147-2009 · DOI
  33. Ordaz, 2014, Probabilistic seismic hazard assessment at global level, Int J Disaster Risk Reduct, 10, 419, 10.1016/j.ijdrr.2014.05.004 · doi:10.1016/j.ijdrr.2014.05.004
  34. Lamprou, 2013, Life-cycle seismic loss estimation and global sensitivity analysis based on stochastic ground motion modeling, Eng Struct, 54, 192, 10.1016/j.engstruct.2013.04.001 · DOI
  35. Franchin, 2018, Improved risk-targeted performance-based seismic design of reinforced concrete frame structures, Earthq Eng Struct Dyn, 47, 49, 10.1002/eqe.2936 · doi:10.1002/eqe.2936
  36. Tse, 2012, Performance and cost evaluation of a smart tuned mass damper for suppressing wind-induced lateral-torsional motion of tall structures, J Struct Eng, 138, 514, 10.1061/(ASCE)ST.1943-541X.0000486 · DOI · Paper page
  37. Saitua, 2018, Optimization of height-wise dampers distribution considering practical design issues, Eng Struct, 173, 768, 10.1016/j.engstruct.2018.04.008 · doi:10.1016/j.engstruct.2018.04.008
  38. Vetter, 2016, Tuning of stochastic ground motion models for compatibility with ground motion prediction equations, Earthq Eng Struct Dyn, 45, 893, 10.1002/eqe.2690 · doi:10.1002/eqe.2690
  39. Jalayer, 2008, Effects of two alternative representations of ground-motion uncertainty in probabilistic seismic demand assessment of structures, Earthq Eng Struct Dyn, 37, 61, 10.1002/eqe.745 · doi:10.1002/eqe.745

Cited by

See all 133

Metadata

Authors
Ruiz, R., Taflanidis, A. A., Giaralis, A., & Lopez-Garcia, D.
Venue
Engineering Structures
Publisher
Elsevier BV
Published
2018-12
Volume
177
Pages
836-850
ISSN
0141-0296 (ISSN-L)
OpenAlex
W2898484079
Cited by
133
References
13
FWCI
8.08
Type
journal article
Language
en
Open access
bronze
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Funders
EPSRC (EP/M017621/1)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Risk-informed optimization of the tuned mass-damper-inerter (TMDI) for the seismic protection of multi-storey building structures. https://app.cochat.ai/papers/10.1016/j.engstruct.2018.08.074
The paper
Ruiz, R., Taflanidis, A. A., Giaralis, A., & Lopez-Garcia, D. (2018). Risk-informed optimization of the tuned mass-damper-inerter (TMDI) for the seismic protection of multi-storey building structures. Engineering Structures. https://doi.org/10.1016/j.engstruct.2018.08.074

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.