Fundamentals of power systems modelling in the presence of converter-interfaced generation
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This survey paper discusses the fundamentals of power systems modelling in the presence of large amounts of converter-interfaced generation (CIG). By referring to real-life events characterised by anomalous dynamics associated to the presence of CIG, the concepts of narrow versus broad band signals are first recalled along with the limitation of the meaning of apparent power, power factor and reactive power. In this regard, the adequacy of the phasor representation of voltages and currents waveforms is thoroughly discussed. Then, with respect to the central subject of control of power converters, a revised definition of grid-following and grid-forming converters is provided along with a thorough discussion of their associated controls and a comprehensive classification for both classes of converters. Several applications inspired by actual case studies are included in the paper in order to provide realistic application examples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Relevance of Inertia in Power Systems
Tielens, P., & Van Hertem, D. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.11.016 · Cited by 809 · cited 1×
“, [8, 14-17], this paper has the goal to discuss specific aspects related to the fundamentals of power systems modelling in the presence of large amount of CIG.”
BackgroundCurrent Limiting Control With Enhanced Dynamics of Grid-Forming Converters During Fault Conditions
Taul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2931477 · Cited by 466
Seo, G.-S., Colombino, M., Subotic, I., Johnson, B., Gros, D., & Dorfler, F. (2019) · 2019 IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2019.8722028 · Cited by 182
Robust Stability Analysis of Synchronverters Operating in Parallel
Rosso, R., Engelken, S., & Liserre, M. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2896707 · Cited by 117
Self-citationRobust Stability Analysis of LCL Filter Based Synchronverter Under Different Grid Conditions
Rosso, R., Cassoli, J., Buticchi, G., Engelken, S., & Liserre, M. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2867040 · Cited by 89 · cited 10×
“Studies have shown that, in contrast to GFL converters using PLLs [53,59], power-synchronization based algorithms are particularly suitable for weak grid applications [60-62].”
BackgroundMethodResultSelf-citation
Cited by
Grid-Forming Converters: Control Approaches, Grid-Synchronization, and Future Trends—A Review
Rosso, R., Wang, X., Liserre, M., Lu, X., & Engelken, S. (2021) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2021.3074028 · Cited by 1,187
Self-citationGrid-forming converters. A critical review of pilot projects and demonstrators
Musca, R., Vasile, A., & Zizzo, G. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2022.112551 · Cited by 136
Grid-Forming and Spatially Distributed Control Design of Dynamic Virtual Power Plants
Häberle, V., Tayyebi, A., He, X., Prieto-Araujo, E., & Dörfler, F. (2024) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2023.3311481 · Cited by 58
Yuan, Z., Zecchino, A., Cherkaoui, R., & Paolone, M. (2021) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2021.3077696 · Cited by 27
Self-citation
Metadata
- Authors
- Paolone, M., Gaunt, T., Guillaud, X., Liserre, M., Meliopoulos, S., Monti, A., Van Cutsem, T., Vittal, V., & Vournas, C.
- Venue
- Electric Power Systems Research
- Publisher
- Elsevier BV
- Published
- 2020-12
- Volume
- 189
- Pages
- 106811
- ISSN
- 0378-7796 (ISSN-L)
- OpenAlex
- W3048465714
- Cited by
- 211
- References
- 5
- FWCI
- 16.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.