Abstract Obstructive sleep apnea refers to a highly rampant sleep-related breathing disorder. The gold standard examination for diagnosis is polysomnography. Even though it provides highly accurate results, this multi-parametric test is time consuming and expensive. It also does not align with the new trend in health care, where focus is shifted to wellness and prevention. One possible way to address this problem is home health care, through the use of minimal invasive devices, higher accessibility, and provision of low cost diagnosis. To manage this, an automated and portable sleep apnea detector was formulated and assessed. The device utilizes one SpO2 sensor for estimating the heart rate and the oxygen blood level as well. The basis of the proposed analysis method is the connection between heart rate variability and oxygen saturation with d apnea events. The measured signals were then transferred to a cloud-based system architecture to diagnose and warn the remote patients. This solution was used to process the data and display it on both the mobile phone and personal computer. Testing of the proposed algorithms was done using the St. Vincents University Hospital/University College Dublin sleep apnea database. Apart from this database, the researchers utilized data gathered from 10 apnea patient volunteers. The performance of the proposed scheme algorithm achieved an average accuracy, specificity, and sensitivity of 98.54, 98.95%, and 97.05%, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Epidemiology of Obstructive Sleep Apnea: A Population Health Perspective
Young, T., Peppard, P. E., & Gottlieb, D. J. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2109080 · Cited by 4,244
Kapur, V. K., Auckley, D. H., Chowdhuri, S., Kuhlmann, D. C., Mehra, R., Ramar, K., & Harrod, C. G. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6506 · Cited by 3,253
The Internet of Things—A survey of topics and trends
Whitmore, A., Agarwal, A., & Da Xu, L. (2015) · Information Systems Frontiers · doi:10.1007/s10796-014-9489-2 · Cited by 1,568
Task Force Members, Kushida, C. A., Chediak, A., Berry, R. B., Brown, L. K., Gozal, D., Iber, C., Parthasarathy, S., Quan, S. F., & Rowley, J. A. (2008) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27133 · Cited by 749
Paper‐Based Electrical Respiration Sensor
Güder, F., Ainla, A., Redston, J., Mosadegh, B., Glavan, A., Martin, T. J., & Whitesides, G. M. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201511805 · Cited by 472
Chung, F., Liao, P., Elsaid, H., Islam, S., Shapiro, C. M., & Sun, Y. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318248f4f5 · Cited by 243
Energy efficient wearable sensor node for IoT-based fall detection systems
Nguyen Gia, T., Sarker, V. K., Tcarenko, I., Rahmani, A. M., Westerlund, T., Liljeberg, P., & Tenhunen, H. (2018) · Microprocessors and Microsystems · doi:10.1016/j.micpro.2017.10.014 · Cited by 146
Cited by
Kumar, R., & Tripathi, R. (2021) · The Journal of Supercomputing · doi:10.1007/s11227-020-03570-x · Cited by 177
Evaluating Internet of Medical Things (IoMT)-Based Systems from a Human-Centric Perspective
Kotronis, C., Routis, I., Politi, E., Nikolaidou, M., Dimitrakopoulos, G., Anagnostopoulos, D., Amira, A., Bensaali, F., & Djelouat, H. (2019) · Internet of Things · doi:10.1016/j.iot.2019.100125 · Cited by 50
Bibliometric Analysis and Methodological Review of Mobile Health Services and Applications in India
Pai, R. R., & Alathur, S. (2021) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2020.104330 · Cited by 35
Metadata
- Authors
- Haoyu, L., Jianxing, L., Arunkumar, N., Hussein, A. F., & Jaber, M. M.
- Venue
- Future Generation Computer Systems
- Publisher
- Elsevier BV
- Published
- 2019-09
- Volume
- 98
- Pages
- 69-77
- ISSN
- 0167-739X (ISSN-L)
- OpenAlex
- W2904846276
- Cited by
- 86
- References
- 8
- FWCI
- 5.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An IoMT cloud-based real time sleep apnea detection scheme by using the SpO2 estimation supported by heart rate variability. https://app.cochat.ai/papers/10.1016/j.future.2018.12.001
- The paper
- Haoyu, L., Jianxing, L., Arunkumar, N., Hussein, A. F., & Jaber, M. M. (2019). An IoMT cloud-based real time sleep apnea detection scheme by using the SpO2 estimation supported by heart rate variability. Future Generation Computer Systems. https://doi.org/10.1016/j.future.2018.12.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.