The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Validity and repeatability of inertial measurement units for measuring gait parameters
Open accessAbstract
Inertial measurement units (IMUs) are small wearable sensors that have tremendous potential to be applied to clinical gait analysis. They allow objective evaluation of gait and movement disorders outside the clinic and research laboratory, and permit evaluation on large numbers of steps. However, repeatability and validity data of these systems are sparse for gait metrics. The purpose of this study was to determine the validity and between-day repeatability of spatiotemporal metrics (gait speed, stance percent, swing percent, gait cycle time, stride length, cadence, and step duration) as measured with the APDM Opal IMUs and Mobility Lab system. We collected data on 39 healthy subjects. Subjects were tested over two days while walking on a standard treadmill, split-belt treadmill, or overground, with IMUs placed in two locations: both feet and both ankles. The spatiotemporal measurements taken with the IMU system were validated against data from an instrumented treadmill, or using standard clinical procedures. Repeatability and minimally detectable change (MDC) of the system was calculated between days. IMUs displayed high to moderate validity when measuring most of the gait metrics tested. Additionally, these measurements appear to be repeatable when used on the treadmill and overground. The foot configuration of the IMUs appeared to better measure gait parameters; however, both the foot and ankle configurations demonstrated good repeatability. In conclusion, the IMU system in this study appears to be both accurate and repeatable for measuring spatiotemporal gait parameters in healthy young adults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cicchetti, D. V. (1994) · Psychological Assessment · doi:10.1037/1040-3590.6.4.284 · Cited by 9,349
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Zeni, J. A., Richards, J. G., & Higginson, J. S. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.07.007 · Cited by 1,261
Assessment of spatio-temporal gait parameters from trunk accelerations during human walking
Zijlstra, W., & Hof, A. L. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00190-x · Cited by 870
Smallest real difference, a link between reproducibility and responsiveness
Beckerman, H., Roebroeck, M. E., Lankhorst, G. J., Becher, J. G., Bezemer, P. D., & Verbeek, A. L. M. (2001) · Quality of Life Research · doi:10.1023/a:1013138911638 · Cited by 857
Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
Aminian, K., Najafi, B., Büla, C., Leyvraz, P.-F., & Robert, P. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00008-8 · Cited by 814
A kinematic and kinetic comparison of overground and treadmill walking in healthy subjects
Riley, P. O., Paolini, G., Della Croce, U., Paylo, K. W., & Kerrigan, D. C. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.07.003 · Cited by 694
Local Dynamic Stability Versus Kinematic Variability of Continuous Overground and Treadmill Walking
Dingwell, J. B., Cusumano, J. P., Cavanagh, P. R., & Sternad, D. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1336798 · Cited by 663
Gait Assessment in Parkinson's Disease: Toward an Ambulatory System for Long-Term Monitoring
Salarian, A., Russmann, H., Vingerhoets, F. J. G., Dehollain, C., Blanc, Y., Burkhard, P. R., & Aminian, K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827933 · Cited by 659
Assessment of Walking Features From Foot Inertial Sensing
Sabatini, A. M., Martelloni, C., Scapellato, S., & Cavallo, F. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840727 · Cited by 650
Peters, D. M., Fritz, S. L., & Krotish, D. E. (2013) · Journal of Geriatric Physical Therapy · doi:10.1519/jpt.0b013e318248e20d · Cited by 646
Biomechanics of overground vs. treadmill walking in healthy individuals
Lee, S. J., & Hidler, J. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01380.2006 · Cited by 595
Walking speed influences on gait cycle variability
Jordan, K., Challis, J. H., & Newell, K. M. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.08.010 · Cited by 561
Locomotor adaptation on a split-belt treadmill can improve walking symmetry post-stroke
Reisman, D. S., Wityk, R., Silver, K., & Bastian, A. J. (2007) · Brain · doi:10.1093/brain/awm035 · Cited by 544
A reliable gait phase detection system
Pappas, I. P. I., Popovic, M. R., Keller, T., Dietz, V., & Morari, M. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.928571 · Cited by 495
Levodopa Is a Double‐Edged Sword for Balance and Gait in People With Parkinson's Disease
Curtze, C., Nutt, J. G., Carlson‐Kuhta, P., Mancini, M., & Horak, F. B. (2015) · Movement Disorders · doi:10.1002/mds.26269 · Cited by 404
Clinical Gait Analysis: Theory and Practice
Kirtley, C. (2006) · Cited by 373
Clinical gait analysis. Theory and practice
Maceira-Suárez, E. (2006) · Revista del Pie y Tobillo · Cited by 341
Spain, R. I., St. George, R. J., Salarian, A., Mancini, M., Wagner, J. M., Horak, F. B., & Bourdette, D. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2011.11.026 · Cited by 287
Dejnabadi, H., Jolles, B. M., & Aminian, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851475 · Cited by 286 · cited 1×
“Many of these systems are shown to be reasonably accurate [29,30] and repeatable (ICC ranging between 0.”
BackgroundTest–retest reliability of trunk accelerometric gait analysis
Henriksen, M., Lund, H., Moe-Nilssen, R., Bliddal, H., & Danneskiod-Samsøe, B. (2004) · Gait & Posture · doi:10.1016/s0966-6362(03)00069-9 · Cited by 286
Wearable inertial sensors for human movement analysis
Iosa, M., Picerno, P., Paolucci, S., & Morone, G. (2016) · Expert Review of Medical Devices · doi:10.1080/17434440.2016.1198694 · Cited by 281
Interrater Reliability of Videotaped Observational Gait-Analysis Assessments
Eastlack, M. E., Arvidson, J., Snyder-Mackler, L., Danoff, J. V., & McGarvey, C. L. (1991) · Physical Therapy · doi:10.1093/ptj/71.6.465 · Cited by 259
Continuous Monitoring of Turning in Patients with Movement Disability
El-Gohary, M., Pearson, S., McNames, J., Mancini, M., Horak, F., Mellone, S., & Chiari, L. (2013) · Sensors · doi:10.3390/s140100356 · Cited by 258
Accuracy of the Microsoft Kinect™ for measuring gait parameters during treadmill walking
Xu, X., McGorry, R. W., Chou, L.-S., Lin, J.-H., & Chang, C.-C. (2015) · Gait & Posture · doi:10.1016/j.gaitpost.2015.05.002 · Cited by 239
Fulk, G. D., & Echternach, J. L. (2008) · Journal of Neurologic Physical Therapy · doi:10.1097/npt0b013e31816593c0 · Cited by 233
Hollman, J. H., Watkins, M. K., Imhoff, A. C., Braun, C. E., Akervik, K. A., & Ness, D. K. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2015.09.024 · Cited by 226
Real-time gait event detection for normal subjects from lower trunk accelerations
González, R. C., López, A. M., Rodriguez-Uría, J., Álvarez, D., & Alvarez, J. C. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2009.11.014 · Cited by 205
Long-term monitoring of gait in Parkinson's disease
Moore, S. T., MacDougall, H. G., Gracies, J.-M., Cohen, H. S., & Ondo, W. G. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.09.011 · Cited by 198
Reliability of videotaped observational gait analysis in patients with orthopedic impairments
Brunnekreef, J. J., van Uden, C. J., van Moorsel, S., & Kooloos, J. G. (2005) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-6-17 · Cited by 196
de Vet, H. C. W., Bouter, L. M., Bezemer, P. D., & Beurskens, A. J. H. M. (2001) · PubMed · Cited by 195
Visual gait analysis: the development of a clinical assessment and scale
Lord, S. E., Halligan, P. W., & Wade, D. T. (1998) · Clinical Rehabilitation · doi:10.1191/026921598666182531 · Cited by 194
Measurement of foot placement and its variability with inertial sensors
Rebula, J. R., Ojeda, L. V., Adamczyk, P. G., & Kuo, A. D. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.05.012 · Cited by 180
Self-citationContinuous monitoring of turning in Parkinson’s disease: Rehabilitation potential
Mancini, M., El-Gohary, M., Pearson, S., McNames, J., Schlueter, H., Nutt, J. G., King, L. A., & Horak, F. B. (2015) · NeuroRehabilitation · doi:10.3233/nre-151236 · Cited by 175
de Vet, H. C. W., Bouter, L. M., Bezemer, P. D., & Beurskens, A. J. H. M. (2001) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462301107038 · Cited by 171
Potential of APDM mobility lab for the monitoring of the progression of Parkinson’s disease
Mancini, M., & Horak, F. B. (2016) · Expert Review of Medical Devices · doi:10.1586/17434440.2016.1153421 · Cited by 163
Kesar, T. M., Binder‐Macleod, S. A., Hicks, G. E., & Reisman, D. S. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2010.11.024 · Cited by 159
Monitoring gait in multiple sclerosis with novel wearable motion sensors
Moon, Y., McGinnis, R. S., Seagers, K. A., Motl, R. W., Sheth, N., Wright, J. A., Ghaffari, R., & Sosnoff, J. J. (2017) · PLoS ONE · doi:10.1371/journal.pone.0171346 · Cited by 134
Quasi real-time gait event detection using shank-attached gyroscopes
Lee, J. K., & Park, E. J. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0736-0 · Cited by 120
Kitagawa, N., & Ogihara, N. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2016.01.014 · Cited by 106
Lewek, M. D., & Randall, E. P. (2011) · Neurology Report · doi:10.1097/npt.0b013e318227fe70 · Cited by 105
Validity and reliability of an IMU-based method to detect APAs prior to gait initiation
Mancini, M., Chiari, L., Holmstrom, L. A., Salarian, A., & Horak, F. B. (2015) · Gait & Posture · doi:10.1016/j.gaitpost.2015.08.015 · Cited by 103
Viehweger, E., Zürcher, L., Hélix, M., Rohon, M.-A., Jacquemier, M., Scavarda, D., Jouve, J.-L., Bollini, G., Loundou, A., & Siméoni, M.-C. (2010) · Annals of Physical and Rehabilitation Medicine · doi:10.1016/j.rehab.2010.09.002 · Cited by 96
Ong, A. M. L., Hillman, S. J., & Robb, J. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.01.008 · Cited by 78
A low cost real-time motion tracking approach using webcam technology
Krishnan, C., Washabaugh, E. P., & Seetharaman, Y. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.11.048 · Cited by 69
Self-citationThe minimal detectable change of the simplified stroke rehabilitation assessment of movement measure
Lu, W., Wang, C., Lin, J., Sheu, C., & Hsieh, C. (2008) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0230 · Cited by 67
Campanini, I., & Merlo, A. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2009.03.011 · Cited by 53
Evaluation of an inertial sensor system for analysis of timed-up-and-go under dual-task demands
Coulthard, J. T., Treen, T. T., Oates, A., & Lanovaz, J. L. (2015) · Gait & Posture · doi:10.1016/j.gaitpost.2015.03.009 · Cited by 48
Development of an IMU-based foot-ground contact detection (FGCD) algorithm
Kim, M., & Lee, D. (2016) · Ergonomics · doi:10.1080/00140139.2016.1174314 · Cited by 34
Effects of Levodopa on Postural Strategies in Parkinson's disease
Baston, C., Mancini, M., Rocchi, L., & Horak, F. B. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2016.02.009 · Cited by 32
Lower Extremity Kinematic Profile of Gait of Patients After Ankle Fracture: A Case-Control Study
Elbaz, A., Mor, A., Segal, G., Bar, D., Monda, M., Kish, B., Nyska, M., & Palmanovich, E. (2016) · The Journal of Foot & Ankle Surgery · doi:10.1053/j.jfas.2016.04.004 · Cited by 19
Cited by
Kobsar, D., Charlton, J. M., Tse, C. T. F., Esculier, J.-F., Graffos, A., Krowchuk, N. M., Thatcher, D., & Hunt, M. A. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00685-3 · Cited by 305
Yeo, S. S., & Park, G. Y. (2020) · Sensors · doi:10.3390/s20051343 · Cited by 56
“Nevertheless, despite this shortcoming, the advantages of IMU systems are that they are increasingly utilized in industry and for medical diagnostic purposes [17,18].”
Background
Metadata
- Authors
- Washabaugh, E. P., Kalyanaraman, T., Adamczyk, P. G., Claflin, E. S., & Krishnan, C.
- Venue
- Gait & Posture
- Publisher
- Elsevier BV
- Published
- 2017-06
- Volume
- 55
- Pages
- 87-93
- ISSN
- 0966-6362 (ISSN-L)
- OpenAlex
- W2606165363
- Cited by
- 329
- References
- 51
- FWCI
- 58.16
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.