Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 332

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

A leadless pacemaker in the real-world setting: The Micra Transcatheter Pacing System Post-Approval Registry

Open access
Roberts, Paul R., Clementy, Nicolas, Al Samadi, Faisal, Garweg, Christophe, Martinez-Sande, Jose Luis, Iacopino, Saverio, Johansen, Jens Brock, Vinolas Prat, Xavier, Kowal, Robert C., Klug, Didier, Mont, Lluis, Steffel, Jan, Li, Shelby, Van Osch, Dirk, El-Chami, Mikhael F.·2017·Heart Rhythm

Abstract

BACKGROUND: First-in-man studies of leadless pacemakers have demonstrated high rates of implant success, and safety and efficacy objectives were achieved. Outside of the investigational setting, there are concerns, particularly over cardiac effusion and perforation, device dislodgement, infection, telemetry, and battery issues. OBJECTIVE: The acute performance of the Micra transcatheter pacemaker from a worldwide Post-Approval Registry is reported. METHODS: The registry is an ongoing prospective single-arm observational study designed to assess the safety and effectiveness of Micra in the post-approval setting. The safety end point was system- or procedure-related major complications at 30 days post implant. We compared the major complication rate with that of the 726 patients from the investigational study. Electrical performance was also characterized. RESULTS: The device was successfully implanted in 792 of 795 registry patients (99.6%) by 149 implanters at 96 centers in 20 countries. Through 30 days post implant, a total of 13 major complications occurred in 12 patients, for a major complication rate of 1.51% (95% confidence interval, 0.78%-2.62%). Major complications included cardiac effusion/perforation (1, 0.13%), device dislodgement (1, 0.13%), and sepsis (1, 0.13%). After adjusting for baseline differences, the rate of major complications in the registry trended lower than the investigational trial (odds ratio, 0.58, 95% confidence interval, 0.27-1.25; P = .16). Early pacing capture thresholds were low and stable. CONCLUSION: Performance of the Micra transcatheter pacemaker in a real-world setting demonstrates a high rate (99.6%) of implant success and low rate (1.51%) of major complications through 30 days post implant. In particular, the rates of pericardial effusion, device dislodgement, and infection were low, reinforcing the positive results seen in the investigational study.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.hrthm.2017.05.017

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 332

Metadata

Authors
Roberts, P. R., Clementy, N., Al Samadi, F., Garweg, C., Martinez-Sande, J. L., Iacopino, S., Johansen, J. B., Vinolas Prat, X., Kowal, R. C., Klug, D., Mont, L., Steffel, J., Li, S., Van Osch, D., & El-Chami, M. F.
Venue
Heart Rhythm
Publisher
Elsevier BV
Published
2017-09
Volume
14
Issue
9
Pages
1375-1379
ISSN
1547-5271 (ISSN-L)
OpenAlex
W2612818999
Cited by
332
References
8
FWCI
26.27
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A leadless pacemaker in the real-world setting: The Micra Transcatheter Pacing System Post-Approval Registry. https://app.cochat.ai/papers/10.1016/j.hrthm.2017.05.017
The paper
Roberts, P. R., Clementy, N., Al Samadi, F., Garweg, C., Martinez-Sande, J. L., Iacopino, S., Johansen, J. B., Vinolas Prat, X., Kowal, R. C., Klug, D., Mont, L., Steffel, J., Li, S., Van Osch, D., & El-Chami, M. F. (2017). A leadless pacemaker in the real-world setting: The Micra Transcatheter Pacing System Post-Approval Registry. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2017.05.017

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.