The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Updated performance of the Micra transcatheter pacemaker in the real-world setting: A comparison to the investigational study and a transvenous historical control
Open accessAbstract
BACKGROUND: Early results of the Micra Investigational Device Exemption (IDE) study and Micra Post-Approval Registry (PAR) demonstrated excellent safety and efficacy performance; however, intermediate-term results across a large patient population in the real-world setting have not been evaluated. OBJECTIVES: We report updated performance of the Micra transcatheter pacemaker from a worldwide PAR and compare it with the IDE study as well as a transvenous historical control. METHODS: The safety objective of the analysis was system- or procedure-related major complications through 12 months postimplantation. We compared the major complication rate with that of the 726 patients from the IDE and with a reference data set of 2667 patients with transvenous pacemakers by using a Fine-Gray competing risk model. RESULTS: The Micra device was successfully implanted in 1801 of 1817 patients (99.1%). The mean follow-up period was 6.8 ± 6.9 months. Through 12 months, the major complication rate was 2.7% (95% confidence interval [CI] 2.0%-3.7%). The risk of major complications for Micra PAR patients was 63% lower than that for patients with transvenous pacemakers through 12 months postimplantation (hazard ratio 0.37; 95% CI 0.27-0.52; P < .001). The major complication rate trended lower in the PAR than in the IDE study (hazard ratio 0.71; 95% CI 0.44-1.1; P = .160), driven by the lower pericardial effusion rate in the PAR. There were 3 cases of infection associated with the procedure, but none required device removal and there were no battery or telemetry issues. Pacing thresholds were low and stable through 12 months postimplantation. CONCLUSION: Performance of the Micra transcatheter pacemaker in international clinical practice remains consistent with previously reported data. Major complications were infrequent and occurred 63% less often compared to transvenous systems. CLINICAL TRIAL REGISTRATION: Micra Transcatheter Pacing System Post-Approval Registry ClinicalTrials.gov identifier: NCT02536118; Micra Transcatheter Pacing Study ClinicalTrials.gov identifier: NCT02004873.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Leadless Intracardiac Transcatheter Pacing System
Reynolds, D., Duray, G. Z., Omar, R., Soejima, K., Neuzil, P., Zhang, S., Narasimhan, C., Steinwender, C., Brugada, J., Lloyd, M., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1511643 · Cited by 933
Self-citationKirkfeldt, R. E., Johansen, J. B., Nohr, E. A., Jorgensen, O. D., & Nielsen, J. C. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht511 · Cited by 871
Self-citationUdo, E. O., Zuithoff, N. P. A., van Hemel, N. M., de Cock, C. C., Hendriks, T., Doevendans, P. A., & Moons, K. G. M. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.014 · Cited by 597
Percutaneous Implantation of an Entirely Intracardiac Leadless Pacemaker
Reddy, V. Y., Exner, D. V., Cantillon, D. J., Doshi, R., Bunch, T. J., Tomassoni, G. F., Friedman, P. A., Estes, N. A. M., Ip, J., Niazi, I., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1507192 · Cited by 539
Roberts, P. R., Clementy, N., Al Samadi, F., Garweg, C., Martinez-Sande, J. L., Iacopino, S., Johansen, J. B., Vinolas Prat, X., Kowal, R. C., Klug, D., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.017 · Cited by 332
Self-citationDuray, G. Z., Ritter, P., El-Chami, M., Narasimhan, C., Omar, R., Tolosana, J. M., Zhang, S., Soejima, K., Steinwender, C., Rapallini, L., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.01.035 · Cited by 302
Self-citationVámos, M., Erath, J. W., Benz, A. P., Bári, Z., Duray, G. Z., & Hohnloser, S. H. (2016) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13140 · Cited by 91
How to Implant a Leadless Pacemaker With a Tine‐Based Fixation
El‐Chami, M. F., Roberts, P. R., Kypta, A., Omdahl, P., Bonner, M. D., Kowal, R. C., & Duray, G. Z. (2016) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13092 · Cited by 66
Self-citationPyatt, J. R., Somauroo, J. D., Jackson, M., Grayson, A. D., Osula, S., Aggarwal, R. K., Charles, R. G., & Connelly, D. T. (2002) · EP Europace · doi:10.1053/eupc.2002.0233 · Cited by 61
Complete encapsulation of a leadless cardiac pacemaker
Kypta, A., Blessberger, H., Lichtenauer, M., & Steinwender, C. (2015) · Clinical Research in Cardiology · doi:10.1007/s00392-015-0929-x · Cited by 54
Cited by
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · EP Europace · doi:10.1093/europace/euab232 · Cited by 914
A Dual-Chamber Leadless Pacemaker
Knops, R. E., Reddy, V. Y., Ip, J. E., Doshi, R., Exner, D. V., Defaye, P., Canby, R., Bongiorni, M. G., Shoda, M., Hindricks, G., et al. (2023) · New England Journal of Medicine · doi:10.1056/nejmoa2300080 · Cited by 283
Atrioventricular Synchronous Pacing Using a Leadless Ventricular Pacemaker
Steinwender, C., Khelae, S. K., Garweg, C., Chan, J. Y. S., Ritter, P., Johansen, J. B., Sagi, V., Epstein, L. M., Piccini, J. P., Pascual, M., et al. (2020) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2019.10.017 · Cited by 257
Self-citation
Metadata
- Authors
- El-Chami, M. F., Al-Samadi, F., Clementy, N., Garweg, C., Martinez-Sande, J. L., Piccini, J. P., Iacopino, S., Lloyd, M., Viñolas Prat, X., Jacobsen, M. D., Ritter, P., Johansen, J. B., Tondo, C., Liu, F., Fagan, D. H., Eakley, A. K., & Roberts, P. R.
- Venue
- Heart Rhythm
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 15
- Issue
- 12
- Pages
- 1800-1807
- ISSN
- 1547-5271 (ISSN-L)
- OpenAlex
- W2885247491
- Cited by
- 355
- References
- 10
- FWCI
- 23.74
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Updated performance of the Micra transcatheter pacemaker in the real-world setting: A comparison to the investigational study and a transvenous historical control. https://app.cochat.ai/papers/10.1016/j.hrthm.2018.08.005
- The paper
- El-Chami, M. F., Al-Samadi, F., Clementy, N., Garweg, C., Martinez-Sande, J. L., Piccini, J. P., Iacopino, S., Lloyd, M., Viñolas Prat, X., Jacobsen, M. D., Ritter, P., Johansen, J. B., Tondo, C., Liu, F., Fagan, D. H., Eakley, A. K., & Roberts, P. R. (2018). Updated performance of the Micra transcatheter pacemaker in the real-world setting: A comparison to the investigational study and a transvenous historical control. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2018.08.005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.