ICRP Publication 121: Radiological Protection in Paediatric Diagnostic and Interventional Radiology
Abstract
Paediatric patients have a higher average risk of developing cancer compared with adults receiving the same dose. The longer life expectancy in children allows more time for any harmful effects of radiation to manifest, and developing organs and tissues are more sensitive to the effects of radiation. This publication aims to provide guiding principles of radiological protection for referring clinicians and clinical staff performing diagnostic imaging and interventional procedures for paediatric patients. It begins with a brief description of the basic concepts of radiological protection, followed by the general aspects of radiological protection, including principles of justification and optimisation. Guidelines and suggestions for radiological protection in specific modalities - radiography and fluoroscopy, interventional radiology, and computed tomography - are subsequently covered in depth. The report concludes with a summary and recommendations. The importance of rigorous justification of radiological procedures is emphasised for every procedure involving ionising radiation, and the use of imaging modalities that are non-ionising should always be considered. The basic aim of optimisation of radiological protection is to adjust imaging parameters and institute protective measures such that the required image is obtained with the lowest possible dose of radiation, and that net benefit is maximised to maintain sufficient quality for diagnostic interpretation. Special consideration should be given to the availability of dose reduction measures when purchasing new imaging equipment for paediatric use. One of the unique aspects of paediatric imaging is with regards to the wide range in patient size (and weight), therefore requiring special attention to optimisation and modification of equipment, technique, and imaging parameters. Examples of good radiographic and fluoroscopic technique include attention to patient positioning, field size and adequate collimation, use of protective shielding, optimisation of exposure factors, use of pulsed fluoroscopy, limiting fluoroscopy time, etc. Major paediatric interventional procedures should be performed by experienced paediatric interventional operators, and a second, specific level of training in radiological protection is desirable (in some countries, this is mandatory). For computed tomography, dose reduction should be optimised by the adjustment of scan parameters (such as mA, kVp, and pitch) according to patient weight or age, region scanned, and study indication (e.g. images with greater noise should be accepted if they are of sufficient diagnostic quality). Other strategies include restricting multiphase examination protocols, avoiding overlapping of scan regions, and only scanning the area in question. Up-to-date dose reduction technology such as tube current modulation, organ-based dose modulation, auto kV technology, and iterative reconstruction should be utilised when appropriate. It is anticipated that this publication will assist institutions in encouraging the standardisation of procedures, and that it may help increase awareness and ultimately improve practices for the benefit of patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
The 2007 recommendations of the International Commission on Radiological Protection
Valentin, J. (2007) · Elsevier eBooks · Cited by 4,105
Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007
Berrington de González, A. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.440 · Cited by 1,888
Solid Cancer Incidence in Atomic Bomb Survivors: 1958–1998
Preston, D. L., Ron, E., Tokuoka, S., Funamoto, S., Nishi, N., Soda, M., Mabuchi, K., & Kodama, K. (2007) · Radiation Research · doi:10.1667/rr0763.1 · Cited by 1,753
Kuppermann, N., Holmes, J. F., Dayan, P. S., Hoyle, J. D., Atabaki, S. M., Holubkov, R., Nadel, F. M., Monroe, D., Stanley, R. M., Borgialli, D. A., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)61558-0 · Cited by 1,631
Valentin, J. (2000) · Annals of the ICRP · doi:10.1016/s0146-6453(01)00004-5 · Cited by 964
American College of Radiology White Paper on Radiation Dose in Medicine
Amis, E. S., Butler, P. F., Applegate, K. E., Birnbaum, S. B., Brateman, L. F., Hevezi, J. M., Mettler, F. A., Morin, R. L., Pentecost, M. J., Smith, G. G., et al. (2007) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2007.03.002 · Cited by 902
Balter, S., Hopewell, J. W., Miller, D. L., Wagner, L. K., & Zelefsky, M. J. (2010) · Radiology · doi:10.1148/radiol.2542082312 · Cited by 600
Valentin, J. (2003) · Annals of the ICRP · doi:10.1016/s0146-6453(03)00024-1 · Cited by 521
Donnelly, L. F., Emery, K. H., Brody, A. S., Laor, T., Gylys-Morin, V. M., Anton, C. G., Thomas, S. R., & Frush, D. P. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760303 · Cited by 480
Self-citationManaging patient dose in computed tomography
(2000) · Annals of the ICRP · doi:10.1016/s0146-6453(01)00049-5 · Cited by 375
Strauss, K. J., Goske, M. J., Kaste, S. C., Bulas, D., Frush, D. P., Butler, P., Morrison, G., Callahan, M. J., & Applegate, K. E. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.4091 · Cited by 305
Self-citationPregnancy and medical radiation
Valentin, J. (2000) · Medical Entomology and Zoology · Cited by 282
Contents, preface, executive summary, chapters 1 and 2
Valentin, J. (2005) · Annals of the ICRP · doi:10.1016/j.icrp.2005.11.002 · Cited by 269
Dose Reduction in Pediatric CT: A Rational Approach
Boone, J. M., Geraghty, E. M., Seibert, J. A., & Wootton-Gorges, S. L. (2003) · Radiology · doi:10.1148/radiol.2282020471 · Cited by 253
Yu, L., Bruesewitz, M. R., Thomas, K. B., Fletcher, J. G., Kofler, J. M., & McCollough, C. H. (2011) · RadioGraphics · doi:10.1148/rg.313105079 · Cited by 217
Greess, H., Nömayr, A., Wolf, H., Baum, U., Lell, M., Böwing, B., Kalender, W., & Bautz, W. A. (2002) · European Radiology · doi:10.1007/s00330-001-1255-4 · Cited by 192
Verdun, F. R., Gutierrez, D., Vader, J. P., Aroua, A., Alamo-Maestre, L. T., Bochud, F., & Gudinchet, F. (2008) · European Radiology · doi:10.1007/s00330-008-0963-4 · Cited by 169
Lucaya, J., Piqueras, J., García-Peña, P., Enríquez, G., García-Macías, M., & Sotil, J. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.175.4.1750985 · Cited by 165
Recommended Standards For The Routine Performance Testing of Diagnostic X-Ray Imaging Systems
Evans, S. (1998) · Journal of Radiological Protection · doi:10.1088/0952-4746/18/2/023 · Cited by 159
Hart, D. B., Mc, H., & Bf, W. (2007) · Europe PMC (PubMed Central) · Cited by 156
Geleijns, J., Salvadó, M., Veldkamp, W. J. H., Tortosa, M. L., & Calzado, A. (2006) · European Radiology · doi:10.1007/s00330-006-0217-2 · Cited by 121
CODY, D. D., Moxley, D. M., Krugh, K. T., O'Daniel, J. C., Wagner, L. K., & Eftekhari, F. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.182.4.1820849 · Cited by 117
Pediatric Chest MDCT Using Tube Current Modulation: Effect on Radiation Dose with Breast Shielding
Coursey, C. A., Frush, D. P., Yoshizumi, T. T., Toncheva, G. I., Nguyen, G., & Greenberg, S. B. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.07.2017 · Cited by 116
Self-citationComputed Tomography Dose Assessment - A Practical Approach
Leitz, W., Axelsson, B., & Szendrö, G. (1995) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a082564 · Cited by 114
Improved Pediatric Multidetector Body CT Using a Size-Based Color-Coded Format
Frush, D. P., Soden, B., Frush, K. S., & Lowry, C. R. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.3.1780721 · Cited by 107
Self-citationO’Connor, O. J., Vandeleur, M., McGarrigle, A. M., Moore, N., McWilliams, S., McSweeney, S. E., O‘Neill, M. F., Chróinín, M. N., & Maher, M. M. (2010) · Radiology · doi:10.1148/radiol.10100278 · Cited by 90
Karmazyn, B. W., Frush, D. P., Applegate, K. E., Maxfield, C. M., Cohen, M. D., & Jones, R. P. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.08.1391 · Cited by 89
Self-citationVock, P. (2005) · European Radiology · doi:10.1007/s00330-005-2856-0 · Cited by 80
Single versus Multi–Detector Row CT
Thornton, F. J., Paulson, E. K., Yoshizumi, T. T., Frush, D. P., & Nelson, R. C. (2003) · Academic Radiology · doi:10.1016/s1076-6332(03)80026-0 · Cited by 69
Self-citationBrisse, H. J., & Aubert, B. (2009) · Journal de Radiologie · doi:10.1016/s0221-0363(09)72471-0 · Cited by 69
Key factors in the optimization of paediatric X-ray practice
Cook, J., Kyriou, J., Pettett, A., Fitzgerald, M., Shah, K. J., & Pablot, S. M. (2001) · British Journal of Radiology · doi:10.1259/bjr.74.887.741032 · Cited by 46
Paediatric and adult computed tomography practice and patient dose in Australia
Moss, M., & McLean, D. (2006) · Australasian Radiology · doi:10.1111/j.1440-1673.2005.01544.x · Cited by 45
Results of a Dosimetry Study in the European Community on Frequent X Ray Examination in Infants
Schneider, K. O., Fendel, H., Bakawski, C., Stein, E. G., Kohn, M., Kellner, M. W., Schweighofer, K., Cartagena, G., Padovani, R., Panzer, W., et al. (1992) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a081327 · Cited by 40
Dauer, L. T., Casciotta, K. A., Erdi, Y. E., & Rothenberg, L. N. (2007) · BMC Medical Imaging · doi:10.1186/1471-2342-7-5 · Cited by 34
Macgregor, D. M., & McKie, L. (2005) · Emergency Medicine Journal · doi:10.1136/emj.2004.017160 · Cited by 25
EFFECTIVE DOSE VARIATION IN PEDIATRIC COMPUTED TOMOGRAPHY: DOSE REFERENCE LEVELS IN GREECE
Yakoumakis, E. N., Karlatira, M., Gialousis, G., Dimitriadis, A., Makri, T. K., & Georgiou, E. K. (2009) · Health Physics · doi:10.1097/01.hp.0000363840.78169.1b · Cited by 19
Let's image gently: Reducing excessive reliance on CT scans
Dauer, L. T., Germain, J. S., & Meyers, P. A. (2008) · Pediatric Blood & Cancer · doi:10.1002/pbc.21725 · Cited by 17
Impact of Radiographic Imaging Criteria on Dose and Image Quality in Infants in an EC-Wide Survey
Schneider, K., Kohn, M. M., Bakowski, C., Stein, E. G., Freidhof, C., Horwitz, A. E., Padovani, R., Wall, B. F., Panzer, W., & Fendel, H. (1993) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a081904 · Cited by 13
Horwitz, A. E., Schweighofer-Berberish, K., Schneider, K. O., Kohn, M. M., Bakowski, C., Stein, E., Freidhof, C., & Fendel, H. (1993) · Radiation Protection Dosimetry · doi:10.1093/rpd/49.1-3.79 · Cited by 7
Cited by
Reisz, J. A., Bansal, N., Qian, J., Zhao, W., & Furdui, C. M. (2014) · Antioxidants & Redox Signaling · doi:10.1089/ars.2013.5489 · Cited by 833
Pediatric Exposures to Ionizing Radiation: Carcinogenic Considerations
Kutanzi, K., Lumen, A., Koturbash, I., & Miousse, I. (2016) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph13111057 · Cited by 287
ICRP Publication 139: Occupational Radiological Protection in Interventional Procedures
López, P. O., Dauer, L. T., Loose, R., Martin, C. J., Miller, D. L., Vañó, E., Doruff, M., Padovani, R., Massera, G., & Yoder, C. (2018) · Annals of the ICRP · doi:10.1177/0146645317750356 · Cited by 276
Alenazi, K., Alahmad, H., Algamdi, S., Alhailiy, A., Alkhybari, E., Alhulail, A., Fisal, N., & Albeshan, S. (2024) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2024.111690 · Cited by 3
Metadata
- Authors
- Khong, P.-L., Ringertz, H., Donoghue, V., Frush, D., Rehani, M., Appelgate, K., & Sanchez, R.
- Venue
- Annals of the ICRP
- Publisher
- SAGE Publications
- Published
- 2013-04
- Volume
- 42
- Issue
- 2
- Pages
- 1-63
- ISSN
- 0146-6453 (ISSN-L)
- 1872-969X
- OpenAlex
- W2087294275
- Cited by
- 363
- References
- 40
- FWCI
- 14.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.