Investigating the effects of temperature on photoplethysmography

Open access
Khan, Musabbir, Pretty, Christopher G., Amies, Alexander C., Elliott, Rodney, Shaw, Geoffrey M., Chase, J. Geoffrey·2015·IFAC-PapersOnLine

Abstract

Pulse oximetry is a commonly used technique to determine arterial oxygen saturation (SpO 2 ) and heart rate. This method uses photoplethysmography (PPG) signals to estimate SpO 2 . However, pulse oximeters can be less accurate at cold temperatures. In this research, the effects of temperature on PPG signal quality was investigated for a group of 20 adult volunteers. Raw PPG data was obtained using a custom pulse oximeter (PO) system. Three tests were performed with the subject's hand maintained at baseline, cold, and warm temperatures. Analysis showed the median PPG signal RMS, as an indicator of signal-to-noise, for the warm test was 0.0289 V [IQR = 0.0262 - 0.0315 V] compared to the baseline test's 0.0174 V [IQR = 0.0104 - 0.0285 V] and the cold test's 0.0066 V [IQR = 0.0053 - 0.0106V]. This improvement of up to 4x in signal quality was associated with a closer match between the SpO 2 values estimated by the PO system and a commercial pulse oximeter. Paired RMS value comparison between the three tests showed a statistically significant difference for all P-values (P < 0.004). Results indicate that warm temperatures improve PPG quality and thus pulse oximeter accuracy.

Integrity signals

Registry

Crossref · 10.1016/j.ifacol.2015.10.166

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Khan, M., Pretty, C. G., Amies, A. C., Elliott, R., Shaw, G. M., & Chase, J. G.
Affiliations
  • University of Canterbury (NZ)
  • Christchurch Hospital (NZ)
Corresponding author
  • Khan, Musabbir
  • Chase, J. Geoffrey
Venue
IFAC-PapersOnLine
Publisher
Elsevier BV
Published
2015
Volume
48
Issue
20
Pages
360-365
ISSN
2405-8963 (ISSN-L)
OpenAlex
W2212541523
Cited by
41
References
27
Citations by year
2026: 4 · 2025: 8 · 2024: 6 · 2023: 4 · 2022: 4 · 2021: 8 · 2020: 2 · 2019: 2 · 2018: 2 · 2016: 1
FWCI
0.50
Type
journal article
Language
en
Open access
Locations
IFAC-PapersOnLine (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
Keywords
photoplethysmography, pulse oximetry, temperature effects, arterial oxygen saturation, signal quality, signal-to-noise ratio, low temperature, pulse oximeter accuracy, hand temperature

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review