Cited by 53Non-Invasive Vital Sign MonitoringHemodynamic Monitoring and TherapyCardiovascular Health and Disease Prevention

Measuring venous oxygenation using the photoplethysmograph waveform

Walton, Zachary D., Kyriacou, Panayiotis A., Silverman, David G., Shelley, Kirk H.·2010·Journal of Clinical Monitoring and Computing

Abstract

Objective We investigate the hypothesis that the photoplethysmograph (PPG) waveform can be analyzed to infer regional venous oxygen saturation.Methods Fundamental to the successful isolation of the venous saturation is the identification of PPG characteristics that are unique to the peripheral venous system. Two such characteristics have been identified. First, the peripheral venous waveform tends to reflect atrial contraction. Second, ventilation tends to move venous blood preferentially due to the low pressure and high compliance of the venous system. Red (660 nm) and IR (940 nm) PPG waveforms were collected from 10 cardiac surgery patients using an esophageal PPG probe. These waveforms were analyzed using algorithms written in Mathematica. Four time-domain saturation algorithms (ArtSat, VenSat, ArtInstSat, VenInstSat) and four frequency-domain saturation algorithms (RespDC, RespAC, Cardiac, and Harmonic) were applied to the data set.Results Three of the algorithms for calculating venous saturation (VenSat, VenInstSat, and RespDC) demonstrate significant difference from ArtSat (the conventional time-domain algorithm for measuring arterial saturation) using the Wilcoxon signed-rank test with Bonferroni correction (p < 0.0071).Conclusions This work introduces new algorithms for PPG analysis. Three algorithms (VenSat, VenInstSat, and RespDC) succeed in detecting lower saturation blood. The next step is to confirm the accuracy of the measurement by comparing them to a gold standard (i.e., venous blood gas).

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s10877-010-9248-y

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Venous pressure can add low-frequency noise to the PPG waveform, often between 0 and 0.5 Hz, contributing to baseline oscillations.

    “Venous pressure can also add low-frequency noise to the PPG waveform, the same effects seen by respiration, which is caused by venous anatomy [129,130,131]. Often between 0 and 0.5 Hz, this noise contributes to be baseline oscillations.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Walton, Z. D., Kyriacou, P. A., Silverman, D. G., & Shelley, K. H.
Affiliations
  • Yale University (US)
  • City, University of London (GB)
Corresponding author
Shelley, Kirk H.
Venue
Journal of Clinical Monitoring and Computing
Published
2010-07-20
Volume
24
Issue
4
Pages
295-303
ISSN
  • 1387-1307 (ISSN-L)
  • 1573-2614
OpenAlex
W2083783275
Cited by
53
References
30
Citations by year
2025: 2 · 2024: 4 · 2023: 3 · 2022: 1 · 2021: 3 · 2020: 1 · 2019: 2 · 2018: 3 · 2017: 3 · 2016: 5 · 2015: 8 · 2014: 4 · 2013: 7 · 2012: 4
FWCI
2.64
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Clinical Monitoring and Computing (publishedVersion)
  • PubMed (publishedVersion)
  • City Research Online (City University London) (acceptedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
Keywords
photoplethysmography, venous oxygen saturation, saturation algorithm, frequency domain analysis, cardiac surgery patients, atrial contraction
MeSH terms
Algorithms, Data Interpretation, Statistical, Esophagus, Humans, Oxygen, Pulsatile Flow, Veins, Photoplethysmography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review