A 90-second magnetocardiogram using a novel analysis system to assess for coronary artery stenosis in Emergency department observation unit chest pain patients
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Magnetocardiography (MCG) has been shown to non-invasively detect coronary artery stenosis (CAS). Emergency department (ED) patients with possible acute coronary syndrome (ACS) are commonly placed in an observation unit (OU) for further evaluation. Our objective was to compare a novel MCG analysis system with stress testing (ST) and/or coronary angiography (CA) in non-high risk EDOU chest pain patients. METHODS: This is a prospective pilot study of non-high risk EDOU chest pain patients evaluated with ST and/or CA that underwent a resting 90-second MCG scan between August 2017 and February 2018. A positive MCG scan was defined as having current dipole deviations with dispersion or splitting during the repolarization phase. ST, CA and major adverse cardiac events (MACE) 30 days and 6 months post-discharge assessed. RESULTS: Of 101 study patients, mean age was 56 years and 53.6% were male. MCG scan sensitivity with 95% CI was 27.3% [7.3%, 60.7%], specificity 77.8% [67.5%, 85.6%], PPV 13.0% [3.4%, 34.7%] and NPV 89.7% [80.3%, 95.2%] compared to ST, and 33.3% [7.5%, 70.7%], 78.3% [68.4%, 86.2%], 13% [5.2%, 29.0%] and 92.3% [88.2%, 95.1%] respectively compared to ST and CA. No patients had positive ST, CA or MACE 30 days and 6 months post-discharge. CONCLUSION: This pilot study suggests a resting 90-second MCG scan shows promise in evaluating EDOU chest pain patients for CAS and warrants further study as an alternative testing modality to identify patients safe for discharge. Larger studies are needed to assess accuracy of MCG using this novel analysis system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic Fields
Malmivuo, J., & Plonsey, R. (1995) · doi:10.1093/acprof:oso/9780195058239.001.0001 · Cited by 1,834
Detection of the magnetic field of the heart
Baule, G., & McFee, R. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90075-9 · Cited by 392
Magnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer
Cohen, D., Edelsack, E. A., & Zimmerman, J. E. (1970) · Applied Physics Letters · doi:10.1063/1.1653195 · Cited by 361
Magnetocardiography Predicts Coronary Artery Disease in Patients with Acute Chest Pain
Park, J., Hill, P. M., Chung, N., Hugenholtz, P. G., & Jung, F. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.00634.x · Cited by 109 · cited 1×
“More recent studies have also demonstrated MCG to be superior to echocardiography in detection of acute ischemia [22,23].”
BackgroundTolstrup, K., Madsen, B. E., Ruiz, J. A., Greenwood, S. D., Camacho, J., Siegel, R. J., Gertzen, H. C., Park, J.-W., & Smars, P. A. (2006) · Cardiology · doi:10.1159/000093490 · Cited by 78
Hänninen, H., Takala, P., Mäkijärvi, M., Montonen, J., Korhonen, P., Oikarinen, L., Nenonen, J., Katila, T., & Toivonen, L. (2000) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2000.tb00380.x · Cited by 74
Identification of ischemic heart disease via machine learning analysis on magnetocardiograms
Tantimongcolwat, T., Naenna, T., Isarankura-Na-Ayudhya, C., Embrechts, M. J., & Prachayasittikul, V. (2008) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2008.04.009 · Cited by 57
Kwon, H., Kim, K., Lee, Y.-H., Kim, J.-M., Yu, K. K., Chung, N., & Ko, Y.-G. (2010) · Circulation Journal · doi:10.1253/circj.cj-09-0975 · Cited by 47
Park, J.-W., Leithäuser, B., Vršansky, M., & Jung, F. (2008) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-2008-1064 · Cited by 27
The magnetocardiogram—a new approach to the fields surrounding the heart
Stratbucker, R. A., Hyde, C. M., & Wixson, S. E. (1963) · IRE Transactions on Bio-Medical Electronics · doi:10.1109/tbmel.1963.4322823 · Cited by 18 · cited 1×
“The first reports of using MCG technology in the United States was over 50 years ago [6,7].”
Background
Cited by
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Huang, X., Chen, P., Tang, F., & Hua, N. (2021) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-200905 · Cited by 33
Automated magnetocardiography classification using a deformable convolutional block attention module
Wang, R., Pang, J., Han, X., Xiang, M., & Ning, X. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.107602 · Cited by 9
Wang, R., Liu, Z., Pang, J., Sun, J., Xiang, M., & Ning, X. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3579060 · Cited by 9
Brisinda, D., Fenici, R., & Smars, P. (2022) · Contemporary Cardiology · doi:10.1007/978-3-031-05520-1_17 · Cited by 6
Metadata
- Authors
- Pena, M. E., Pearson, C. L., Goulet, M. P., Kazan, V. M., DeRita, A. L., Szpunar, S. M., & Dunne, R. B.
- Venue
- IJC Heart & Vasculature
- Publisher
- Elsevier BV
- Published
- 2020-02
- Volume
- 26
- Pages
- 100466
- ISSN
- 2352-9067 (ISSN-L)
- OpenAlex
- W2999327828
- Cited by
- 70
- References
- 10
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.