Isolation of SARS-CoV-2 from the air in a car driven by a COVID patient with mild illness
Open accessPublished version of a preprint
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine if viable virus could be isolated from the air within a car driven by a patient infected with SARS-CoV-2, and to assess the size range of the infectious particles. METHODS: We used a Sioutas personal cascade impactor sampler (PCIS) to screen for SARS-CoV-2 in a car driven by a COVID-19 patient. The patient, who had only mild illness without fever or cough and was not wearing a mask, drove the car for 15 min with the air conditioning turned on and windows closed. The PCIS was clipped to the sun-visor above the front passenger seat and was retrieved from the car two hours after completion of the drive. RESULTS: SARS-CoV-2 was detectable at all PCIS stages by PCR and was cultured from the section of the sampler collecting particles in the 0.25-0.50 μm size range. CONCLUSIONS: Our data highlight the potential risk of SARS-CoV-2 transmission by minimally symptomatic persons in the closed space inside of a car and suggest that a substantial component of that risk is via aerosolized virus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Viable SARS-CoV-2 in the air of a hospital room with COVID-19 patients
Lednicky, J. A., Lauzardo, M., Fan, Z. H., Jutla, A., Tilly, T. B., Gangwar, M., Usmani, M., Shankar, S. N., Mohamed, K., Eiguren-Fernandez, A., et al. (2020) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2020.09.025 · Cited by 683
Self-citationFears, A. C., Klimstra, W. B., Duprex, P., Hartman, A., Weaver, S. C., Plante, K. C., Mirchandani, D., Plante, J. A., Aguilar, P. V., Fernández, D., et al. (2020) · doi:10.1101/2020.04.13.20063784 · Cited by 453
Persistence of Severe Acute Respiratory Syndrome Coronavirus 2 in Aerosol Suspensions
Fears, A. C., Klimstra, W. B., Duprex, P., Hartman, A., Weaver, S. C., Plante, K. S., Mirchandani, D., Plante, J. A., Aguilar, P. V., Fernández, D., et al. (2020) · Emerging Infectious Diseases · doi:10.3201/eid2609.201806 · Cited by 453
Fabian, P., McDevitt, J. J., Lee, W.-M., Houseman, E. A., & Milton, D. K. (2009) · J. Environ. Monit. · doi:10.1039/b813520g · Cited by 49 · cited 1×
“For he collection of airborne viruses, the filters are not pre-wetted ith methanol prior to use, which helps preserve virus viability Fabian et al., 2009).”
Research works printed but not linked: 15
- Hamner, 2020, High SARS-CoV-2 attack rate following exposure at a choir practice — Skagit County, Washington, March 20, Morbid Mortal Wkly Rep, 69, 606, 10.15585/mmwr.mm6919e6 · DOI · Paper page
- Lednicky, 2013, Detection and isolation of airborne influenza A H3N2 virus using a Sioutas Personal Cascade Impactor Sampler, Influenza Res Treat, 2013
- Lednicky, 2020, Collection of SARS-CoV-2 virus from the air of a clinic within a university student health care center and analyses of the viral genomic sequence, Aerosol Air Qual Res, 20, 1167, 10.4209/aaqr.2020.05.0202 · doi:10.4209/aaqr.2020.05.0202 · Paper page
- Lee, 2020, The engines of SARS-CoV-2 spread, Science, 370, 406, 10.1126/science.abd8755 · DOI
- Mathai, 2021, Airflows inside passenger cars and implilcatons for airborne disease transmission, Sci Adv, 7, eabe0166, 10.1126/sciadv.abe0166 · DOI
- Mercatelli, 2020, Geographic and genomic distribution of SARS-CoV-2 mutations, Front Microbiol, 11, 1800, 10.3389/fmicb.2020.01800 · DOI · Paper page
- Misra, 2002, Development and evaluation of a personal cascade impactor sampler (PCIS), J Aerosol Sci, 33, 1027, 10.1016/S0021-8502(02)00055-1 · DOI · Paper page
- Ng, 2021, SARS-CoV-2 seroprevalence and transmission risk factors among high-risk close contacts: a retrospective cohort study, Lancet Infect Dis, 21, 333, 10.1016/S1473-3099(20)30833-1 · DOI · Paper page
- Pan, 2019, Collection, particle sizing and detection of airborne viruses, J Appl Microbiol, 127, 1596, 10.1111/jam.14278 · DOI · Paper page
- Park, 2020, Coronavirus disease outbreak in Call Center, South Korea, Emerg Infect Dis J, 26, 10.3201/eid2608.201274 · DOI · Paper page
- Rahmani, 2020, Sampling and detection of corona viruses in air: a mini review, Sci Total Environ, 740
- Santarpia, 2020, Aerosol and surface contamination of SARS-CoV-2 observed in quarantine and isolation care, Sci Rep, 10, 12732, 10.1038/s41598-020-69286-3 · DOI · Paper page
- Somsen, 2020, Small droplet aerosols in poorly ventilated spaces and SARS-CoV-2 transmission, Lancet Respir Med
- Tang, 2009, The effect of environmental parameters on the survival of airborne infectious agents, J R Soc Interface, 6, S737
- Verreault, 2008, Methods for sampling of airborne viruses, Microbiol Mol Biol Rev, 72, 413, 10.1128/MMBR.00002-08 · DOI · Paper page
Cited by
Airborne transmission of respiratory viruses
Wang, C. C., Prather, K. A., Sznitman, J., Jimenez, J. L., Lakdawala, S. S., Tufekci, Z., & Marr, L. C. (2021) · Science · doi:10.1126/science.abd9149 · Cited by 1,543
Ten scientific reasons in support of airborne transmission of SARS-CoV-2
Greenhalgh, T., Jimenez, J. L., Prather, K. A., Tufekci, Z., Fisman, D., & Schooley, R. (2021) · The Lancet · doi:10.1016/s0140-6736(21)00869-2 · Cited by 930
The size and culturability of patient-generated SARS-CoV-2 aerosol
Santarpia, J. L., Herrera, V. L., Rivera, D. N., Ratnesar-Shumate, S., Reid, S. P., Ackerman, D. N., Denton, P. W., Martens, J. W. S., Fang, Y., Conoan, N., et al. (2022) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-021-00376-8 · Cited by 196
Adenaiye, O. O., Lai, J., Bueno de Mesquita, P. J., Hong, F., Youssefi, S., German, J., Tai, S. H. S., Albert, B., Schanz, M., Weston, S., et al. (2022) · Clinical Infectious Diseases · doi:10.1093/cid/ciab797 · Cited by 125
Infectious SARS-CoV-2 Is Emitted in Aerosol Particles
Hawks, S. A., Prussin, A. J., Kuchinsky, S. C., Pan, J., Marr, L. C., & Duggal, N. K. (2021) · mBio · doi:10.1128/mbio.02527-21 · Cited by 57
“Superior to traditional methods for collecting infectious virus (37), this technique has been used to detect infectious SARS-CoV-2 in a hospital and car and directly in exhaled breath of patients (7, 9).”
BackgroundMethod
Metadata
- Authors
- Lednicky, J. A., Lauzardo, M., Alam, M. M., Elbadry, M. A., Stephenson, C. J., Gibson, J. C., & Morris, J. G.
- Venue
- International Journal of Infectious Diseases
- Publisher
- Elsevier BV
- Published
- 2021-07
- Volume
- 108
- Pages
- 212-216
- ISSN
- 1201-9712 (ISSN-L)
- OpenAlex
- W3158775354
- Cited by
- 126
- References
- 4
- FWCI
- 15.60
- Type
- journal article
- Language
- en
- Open access
- gold
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0/ (vor)
- Funders
- Emerging Pathogens Institute, University of Florida
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.