AccNet24: A deep learning framework for classifying 24–hour activity behaviours from wrist–worn accelerometer data under free–living environments
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Although machine learning techniques have been repeatedly used for activity prediction from wearable devices, accurate classification of 24-hour activity behaviour categories from accelerometry data remains a challenge. We developed and validated a deep learning-based framework for classifying 24-hour activity behaviours from wrist-worn accelerometers. METHODS: Using an openly available dataset with free-living wrist-based raw accelerometry data from 151 participants (aged 18-91 years), we developed a deep learning framework named AccNet24 to classify 24-hour activity behaviours. First, the acceleration signal (x, y, and z-axes) was segmented into 30-second nonoverlapping windows, and signal-to-image conversion was performed for each segment. Deep features were automatically extracted from the signal images using transfer learning and transformed into a lower-dimensional feature space. These transformed features were then employed to classify the activity behaviours as sleep, sedentary behaviour, and light-intensity (LPA) and moderate-to-vigorous physical activity (MVPA) using a bidirectional long short-term memory (BiLSTM) recurrent neural network. AccNet24 was trained and validated with data from 101 and 25 randomly selected participants and tested with the remaining unseen 25 participants. We also extracted 112 hand-crafted time and frequency domain features from 30-second windows and used them as inputs to five commonly used machine learning classifiers, including random forest, support vector machines, artificial neural networks, decision tree, and naïve Bayes to classify the 24-hour activity behaviour categories. RESULTS: Using the same training, validation, and test data and window size, the classification accuracy of AccNet24 outperformed the accuracy of the other five machine learning classification algorithms by 16%-30% on unseen data. CONCLUSION: AccNet24, relying on signal-to-image conversion, deep feature extraction, and BiLSTM achieved consistently high accuracy (>95 %) in classifying the 24-hour activity behaviour categories as sleep, sedentary, LPA, and MVPA. The next generation accelerometry analytics may rely on deep learning techniques for activity prediction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Additionally, several studies used a large number of variables for the application of machine learning techniques, with (45), (46), and (47) reporting the use of 117, 112, and 45 features, respectively.”
From A quantitative analysis of fidgeting in ADHD and its relation to performance and sustained attention on a cognitive task (2024) · cites this paper as [46]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
ImageNet: A large-scale hierarchical image database
Deng, J., Dong, W., Socher, R., Li, L.-J., Li, K., & Fei-Fei, L. (2009) · 2009 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2009.5206848 · Cited by 65,333
Deep learning for sensor-based activity recognition: A survey
Wang, J., Chen, Y., Hao, S., Peng, X., & Hu, L. (2019) · Pattern Recognition Letters · doi:10.1016/j.patrec.2018.02.010 · Cited by 2,014
Deep learning for electroencephalogram (EEG) classification tasks: a review
Craik, A., He, Y., & Contreras-Vidal, J. L. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab0ab5 · Cited by 1,758
Comparison of Accelerometer Cut Points for Predicting Activity Intensity in Youth
TROST, S. G., LOPRINZI, P. D., MOORE, R., & PFEIFFER, K. A. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318206476e · Cited by 1,360
Evolution of accelerometer methods for physical activity research
Troiano, R. P., McClain, J. J., Brychta, R. J., & Chen, K. Y. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-093546 · Cited by 968
A scoping review of transfer learning research on medical image analysis using ImageNet
Morid, M. A., Borjali, A., & Del Fiol, G. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.104115 · Cited by 508
Importance of All Movement Behaviors in a 24 Hour Period for Overall Health
Chaput, J.-P., Carson, V., Gray, C., & Tremblay, M. (2014) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph111212575 · Cited by 444
Lee, I.-M., & Shiroma, E. J. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2013-093154 · Cited by 415
Willetts, M., Hollowell, S., Aslett, L., Holmes, C., & Doherty, A. (2018) · Scientific Reports · doi:10.1038/s41598-018-26174-1 · Cited by 250
Walmsley, R., Chan, S., Smith-Byrne, K., Ramakrishnan, R., Woodward, M., Rahimi, K., Dwyer, T., Bennett, D., & Doherty, A. (2022) · British Journal of Sports Medicine · doi:10.1136/bjsports-2021-104050 · Cited by 238
Physical Activity Classification Using the GENEA Wrist-Worn Accelerometer
ZHANG, S., ROWLANDS, A. V., MURRAY, P., & HURST, T. L. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31823bf95c · Cited by 233
Research works printed but not linked: 35
- Xie, 2020, Electronic wearable device and physical activity among US adults: an analysis of 2019 HINTS data, Int. J. Med. Inf., 144, 10.1016/j.ijmedinf.2020.104297 · DOI
- Crouter, 2008, A new 2-regression model for the Actical accelerometer, Br. J. Sports Med., 42, 217, 10.1136/bjsm.2006.033399 · DOI · Paper page
- Winkler, 2012, Identifying sedentary time using automated estimates of accelerometer wear time, Br. J. Sports Med., 46, 436, 10.1136/bjsm.2010.079699 · DOI · Paper page
- Migueles, 2017, Accelerometer data collection and processing criteria to assess physical activity and other outcomes: a systematic review and practical considerations, Sport. Med., 47, 1821, 10.1007/s40279-017-0716-0 · DOI · Paper page
- Kim, 2012, Everything you wanted to know about selecting the “right” Actigraph accelerometer cut-points for youth, but…: a systematic review, J. Sci. Med. Sport, 15, 311, 10.1016/j.jsams.2011.12.001 · DOI · Paper page
- Migueles, 2022, GRANADA consensus on analytical approaches to assess associations with accelerometer-determined physical behaviours (physical activity, sedentary behaviour and sleep) in epidemiological studies, Br. J. Sports Med., 376, 10.1136/bjsports-2020-103604 · DOI · Paper page
- Rosenberger, 2019, The 24-hour activity cycle: a new paradigm for physical activity, Med. Sci. Sports Exerc., 51, 454, 10.1249/MSS.0000000000001811 · DOI · Paper page
- Farrahi, 2021, Compositional associations of sleep and activities within the 24-h cycle with cardiometabolic health markers in adults, Med. Sci. Sports Exerc., 53, 324, 10.1249/MSS.0000000000002481 · DOI
- Farrahi, 2019, Calibration and validation of accelerometer-based activity monitors: a systematic review of machine-learning approaches, Gait Posture, 68, 285, 10.1016/j.gaitpost.2018.12.003 · DOI
- Bassett, 2012, Calibration and validation of wearable monitors, Med. Sci. Sports Exerc., 44, S32, 10.1249/MSS.0b013e3182399cf7 · DOI · Paper page
- de Almeida Mendes, 2018, Calibration of raw accelerometer data to measure physical activity: a systematic review, Gait Posture, 61, 98, 10.1016/j.gaitpost.2017.12.028 · DOI
- Kerr, 2016, Objective assessment of physical activity: classifiers for public health, Med. Sci. Sports Exerc., 48, 951, 10.1249/MSS.0000000000000841 · DOI · Paper page
- Montoye, 2018, Cross-validation and out-of-sample testing of physical activity intensity predictions using a wrist-worn accelerometer, J. Appl. Physiol., 124, 1284, 10.1152/japplphysiol.00760.2017 · DOI
- Farrahi, 2020, Evaluating and enhancing the generalization performance of machine learning models for physical activity intensity prediction from raw acceleration data, IEEE J. Biomed. Heal. Informatics., 24, 27, 10.1109/JBHI.2019.2917565 · DOI
- Clark, 2017, A review of emerging analytical techniques for objective physical activity measurement in humans, Sport. Med., 47, 439, 10.1007/s40279-016-0585-y · DOI
- Narayanan, 2020, Application of raw accelerometer data and machine-learning techniques to characterize human movement behavior: a systematic scoping review, J. Phys. Act. Heal., 17, 360, 10.1123/jpah.2019-0088 · DOI
- Chong, 2021, Machine-learning models for activity class prediction: A comparative study of feature selection and classification algorithms, Gait Posture, 89, 45, 10.1016/j.gaitpost.2021.06.017 · DOI
- Ainsworth, 2011, Compendium of Physical Activities, Med. Sci. Sport. Exerc., 43, 1575, 10.1249/MSS.0b013e31821ece12 · DOI · Paper page
- Litjens, 2017, A survey on deep learning in medical image analysis, Med. Image Anal., 42, 60, 10.1016/j.media.2017.07.005 · DOI · Paper page
- Z. Wang, T. Oates, Imaging time-series to improve classification and imputation, in: Twenty-Fourth Int. Jt. Conf. Artif. Intell., 2015: pp. 3939–3945.
- Pan, 2009, A survey on transfer learning, IEEE Trans. Knowl. Data Eng., 22, 1345, 10.1109/TKDE.2009.191 · DOI · Paper page
- Weiss, 2016, A survey of transfer learning, J. Big Data., 3, 10.1186/s40537-016-0043-6 · DOI · Paper page
- Muhammad, 2022, SAM: Self-augmentation mechanism for COVID-19 detection using chest X-ray images, Knowledge-Based Syst., 241, 10.1016/j.knosys.2022.108207 · DOI
- Bengio, 2013, Representation learning: A review and new perspectives, IEEE Trans. Pattern Anal. Mach. Intell., 35, 1798, 10.1109/TPAMI.2013.50 · DOI · Paper page
- Längkvist, 2014, A review of unsupervised feature learning and deep learning for time-series modeling, Pattern Recogn. Lett., 42, 11, 10.1016/j.patrec.2014.01.008 · DOI · Paper page
- Le, 2011, ICA with reconstruction cost for efficient overcomplete feature learning, Adv. Neural Inf. Process. Syst., 24, 1017
- Sarker, 2021, Deep learning: a comprehensive overview on techniques, taxonomy, applications and research directions, SN Comput. Sci., 2, 1, 10.1007/s42979-021-00815-1 · DOI · Paper page
- Van Houdt, 2020, A review on the long short-term memory model, Artif. Intell. Rev., 53, 5929, 10.1007/s10462-020-09838-1 · DOI · Paper page
- Staudenmayer, 2012, Statistical considerations in the analysis of accelerometry-based activity monitor data, Med. Sci. Sports Exerc., 44, S61, 10.1249/MSS.0b013e3182399e0f · DOI · Paper page
- Faouzi, 2020, pyts: A Python Package for Time Series Classification, J. Mach. Learn. Res., 21, 41
- Dalton, 2012, OLaighin, Comparing supervised learning techniques on the task of physical activity recognition, IEEE J. Biomed. Heal. Informatics., 17, 46, 10.1109/TITB.2012.2223823 · DOI
- Logacjov, 2021, HARTH: A Human Activity Recognition Dataset for Machine Learning, Sensors, 21, 7853, 10.3390/s21237853 · DOI
- Hagenbuchner, 2015, Prediction of activity type in preschool children using machine learning techniques, J. Sci. Med. Sport, 18, 426, 10.1016/j.jsams.2014.06.003 · DOI
- Nawaratne, 2021, Deep learning to predict energy expenditure and activity intensity in free living conditions using wrist-specific accelerometry, J. Sports Sci., 39, 683, 10.1080/02640414.2020.1841394 · DOI
- Xu, 2020, Human activity recognition based on Gramian angular field and deep convolutional neural network, IEEE Access, 8, 199393, 10.1109/ACCESS.2020.3032699 · DOI
Cited by
Son, H. M., Calub, C. A., Fan, B., Dixon, J. F., Rezaei, S., Borden, J., Schweitzer, J. B., & Liu, X. (2024) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2024.1394096 · Cited by 25
Alam, M. S. B., Lameesa, A., Sharmin, S., Afrin, S., Ahmed, S. F., Nikoo, M. R., & Gandomi, A. H. (2025) · Digital Communications and Networks · doi:10.1016/j.dcan.2025.04.001 · Cited by 9
Wang, L., Luo, Z., & Zhang, T. (2025) · BMC Biomedical Engineering · doi:10.1186/s42490-025-00088-2 · Cited by 8
Wang, L., Luo, Z., & Zhang, T. (2024) · doi:10.21203/rs.3.rs-4696057/v1 · Cited by 8
Metadata
- Authors
- Farrahi, V., Muhammad, U., Rostami, M., & Oussalah, M.
- Venue
- International Journal of Medical Informatics
- Publisher
- Elsevier BV
- Published
- 2023-04
- Volume
- 172
- Pages
- 105004
- ISSN
- 1386-5056
- Cited by
- 21
- References
- 14
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by/4.0/ (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.