Identifying sedentary time using automated estimates of accelerometer wear time
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Purpose: The authors evaluated the accuracy of three automated accelerometer wear-time estimation algorithms against self-report. Direct effects on sedentary time (<100 cpm) and indirect effects on moderate-to-vigorous physical activity (MVPA, ≥1952 cpm) time were examined. Methods: A subsample from the 2004/2005 Australian Diabetes, Obesity and Lifestyle Study (n=148) completed activity logs and wore accelerometers for a total of 987 days. A published algorithm that allows movement within non-wear periods (Algorithm 1) was compared with one that allows less movement (Algorithm 2) or no movement (Algorithm 3). Implications for population estimates were examined using 2003/2004 US National Health and Nutrition Examination Survey data. Results: Mean difference per day between the criterion and estimated wear time was negligible for all three algorithms (≤11 min), but 95% limits of agreement (LOA) were wide (±≥2 h). Respectively, the algorithms (1, 2 and 3) misclassified sedentary time as non-wear on 31.9%, 19.4% and 18% of days and misclassified non-wear time as sedentary on 42.8%, 43.7% and 51.3% of days. Use of Algorithm 2 (compared with Algorithm 1) affected population estimates of sedentary time (higher by 20 min/day) but not MVPA time. Agreement between Algorithms 1 and 2 was good for MVPA time (mean difference −0.08, LOA: −2.08, 1.91 min), but not for wear time or sedentary time. Conclusion: Accelerometer wear time can be estimated accurately on average; however, misclassification can be substantial for individuals. Algorithm choice affects estimates of sedentary time. Allowing very limited movement within non-wear periods can improve accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Amount of Time Spent in Sedentary Behaviors in the United States, 2003-2004
Matthews, C. E., Chen, K. Y., Freedson, P. S., Buchowski, M. S., Beech, B. M., Pate, R. R., & Troiano, R. P. (2008) · American Journal of Epidemiology · doi:10.1093/aje/kwm390 · Cited by 2,631
Self-citationToo Much Sitting: The Population Health Science of Sedentary Behavior
Owen, N., Healy, G. N., Matthews, C. E., & Dunstan, D. W. (2010) · Exercise and Sport Sciences Reviews · doi:10.1097/jes.0b013e3181e373a2 · Cited by 2,202
Self-citationValidation of Accelerometer Wear and Nonwear Time Classification Algorithm
CHOI, L., LIU, Z., MATTHEWS, C. E., & BUCHOWSKI, M. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181ed61a3 · Cited by 1,804
Self-citationSitting time and mortality from all causes, cardiovascular disease, and cancer
KATZMARZYK, P. T., CHURCH, T. S., CRAIG, C. L., & BOUCHARD, C. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181930355 · Cited by 1,611
Sedentary time and cardio-metabolic biomarkers in US adults: NHANES 2003–06
Healy, G. N., Matthews, C. E., Dunstan, D. W., Winkler, E. A. H., & Owen, N. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq451 · Cited by 1,368
Self-citationHealy, G. N., Dunstan, D. W., Salmon, J., Cerin, E., Shaw, J. E., Zimmet, P. Z., & Owen, N. (2007) · Diabetes Care · doi:10.2337/dc07-0114 · Cited by 627
Self-citationAccelerometers and pedometers: methodology and clinical application
Corder, K., Brage, S., & Ekelund, U. (2007) · Current Opinion in Clinical Nutrition and Metabolic Care · doi:10.1097/mco.0b013e328285d883 · Cited by 339
Cited by
Young, D. R., Hivert, M.-F., Alhassan, S., Camhi, S. M., Ferguson, J. F., Katzmarzyk, P. T., Lewis, C. E., Owen, N., Perry, C. K., Siddique, J., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000440 · Cited by 791
Self-citationMeasurement of Adults' Sedentary Time in Population-Based Studies
Healy, G. N., Clark, B. K., Winkler, E. A. H., Gardiner, P. A., Brown, W. J., & Matthews, C. E. (2011) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2011.05.005 · Cited by 628
Self-citationAssessment of Wear/Nonwear Time Classification Algorithms for Triaxial Accelerometer
CHOI, L., WARD, S. C., SCHNELLE, J. F., & BUCHOWSKI, M. S. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318258cb36 · Cited by 478
Thorp, A. A., Healy, G. N., Winkler, E., Clark, B. K., Gardiner, P. A., Owen, N., & Dunstan, D. W. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-128 · Cited by 467
Self-citationBuman, M. P., Winkler, E. A. H., Kurka, J. M., Hekler, E. B., Baldwin, C. M., Owen, N., Ainsworth, B. E., Healy, G. N., & Gardiner, P. A. (2014) · American Journal of Epidemiology · doi:10.1093/aje/kwt292 · Cited by 427
“We made additional scoring modifications including a) wear period interruptions to any 3 counts less than 50 counts/minute (16), and b) allowingnonwear periods to continueover themidnight hour.”
MethodSelf-citation
Metadata
- Authors
- Winkler, E. A. H., Gardiner, P. A., Clark, B. K., Matthews, C. E., Owen, N., & Healy, G. N.
- Venue
- British Journal of Sports Medicine
- Publisher
- BMJ
- Published
- 2011-04-18
- Volume
- 46
- Issue
- 6
- Pages
- 436-442
- ISSN
- 0306-3674 (ISSN-L)
- 1473-0480
- OpenAlex
- W1999109704
- Cited by
- 101
- References
- 10
- FWCI
- 6.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Identifying sedentary time using automated estimates of accelerometer wear time. https://app.cochat.ai/papers/10.1136/bjsm.2010.079699
- The paper
- Winkler, E. A. H., Gardiner, P. A., Clark, B. K., Matthews, C. E., Owen, N., & Healy, G. N. (2012). Identifying sedentary time using automated estimates of accelerometer wear time. British Journal of Sports Medicine. https://doi.org/10.1136/bjsm.2010.079699
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.