High-throughput manufacturing of size-tuned liposomes by a new microfluidics method using enhanced statistical tools for characterization
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Microfluidics has recently emerged as a new method of manufacturing liposomes, which allows for reproducible mixing in miliseconds on the nanoliter scale. Here we investigate microfluidics-based manufacturing of liposomes. The aim of these studies was to assess the parameters in a microfluidic process by varying the total flow rate (TFR) and the flow rate ratio (FRR) of the solvent and aqueous phases. Design of experiment and multivariate data analysis were used for increased process understanding and development of predictive and correlative models. High FRR lead to the bottom-up synthesis of liposomes, with a strong correlation with vesicle size, demonstrating the ability to in-process control liposomes size; the resulting liposome size correlated with the FRR in the microfluidics process, with liposomes of 50 nm being reproducibly manufactured. Furthermore, we demonstrate the potential of a high throughput manufacturing of liposomes using microfluidics with a four-fold increase in the volumetric flow rate, maintaining liposome characteristics. The efficacy of these liposomes was demonstrated in transfection studies and was modelled using predictive modeling. Mathematical modelling identified FRR as the key variable in the microfluidic process, with the highest impact on liposome size, polydispersity and transfection efficiency. This study demonstrates microfluidics as a robust and high-throughput method for the scalable and highly reproducible manufacture of size-controlled liposomes. Furthermore, the application of statistically based process control increases understanding and allows for the generation of a design-space for controlled particle characteristics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PLS-regression: a basic tool of chemometrics
Wold, S., Sjöström, M., & Eriksson, L. (2001) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(01)00155-1 · Cited by 10,084
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Lipofection: a highly efficient, lipid-mediated DNA-transfection procedure.
Felgner, P. L., Gadek, T. R., Holm, M., Roman, R., Chan, H. W., Wenz, M., Northrop, J. P., Ringold, G. M., & Danielsen, M. (1987) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.84.21.7413 · Cited by 4,978
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379 · cited 1×
“Microfluidics refers to fluid handling methods in a controlled volume, typically below millimeter scales, which allows for implementation of the mixing process into planar chips (Squires and Quake, 2005).”
BackgroundChaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Design and Analysis of Experiments
Sullivan, G. R. (1998) · Journal of Quality Technology · doi:10.1080/00224065.1998.11979826 · Cited by 1,877
Enhanced gene delivery and mechanism studies with a novel series of cationic lipid formulations.
Felgner, J. H., Kumar, R., Sridhar, C. N., Wheeler, C. J., Tsai, Y. J., Border, R., Ramsey, P., Martin, M., & Felgner, P. L. (1994) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)41980-6 · Cited by 1,312
Pharmaceutical Quality by Design: Product and Process Development, Understanding, and Control
Yu, L. X. (2008) · Pharmaceutical Research · doi:10.1007/s11095-007-9511-1 · Cited by 1,191 · cited 1×
“Depicted are the critical process parameters and the critical quality attributes. transfection efficiency and optimal immune response (McNeil et al., 2010; Liu and Huang, 2002) and was therefore chosen to allow correlation of the systems produced via this new production method with previous studies.”
MethodPreparation of liposomes of defined size distribution by extrusion through polycarbonate membranes
Olson, F., Hunt, C. A., Szoka, F. C., Vail, W. J., & Papahadjopoulos, D. (1979) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(79)90085-3 · Cited by 1,126
Cationic liposome-mediated RNA transfection.
Malone, R. W., Felgner, P. L., & Verma, I. M. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.16.6077 · Cited by 911
Microfluidic Platform for Controlled Synthesis of Polymeric Nanoparticles
Karnik, R., Gu, F., Basto, P., Cannizzaro, C., Dean, L., Kyei-Manu, W., Langer, R., & Farokhzad, O. C. (2008) · Nano Letters · doi:10.1021/nl801736q · Cited by 887
Multi- and megavariate data analysis
Eriksson, L. (2006) · Cited by 736
Microfluidic Synthesis of Highly Potent Limit-size Lipid Nanoparticles for In Vivo Delivery of siRNA
Belliveau, N. M., Huft, J., Lin, P. J., Chen, S., Leung, A. K., Leaver, T. J., Wild, A. W., Lee, J. B., Taylor, R. J., Tam, Y. K., et al. (2012) · Molecular Therapy - Nucleic Acids · doi:10.1038/mtna.2012.28 · Cited by 685 · cited 2×
“Furthermore, the option of parallelization of the mixing cartridges allows for scalability as a high throughput method (Belliveau et al., 2012).”
BackgroundMethodSome recent developments in PLS modeling
Wold, S., Trygg, J., Berglund, A., & Antti, H. (2001) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(01)00156-3 · Cited by 559
Controlled Vesicle Self-Assembly in Microfluidic Channels with Hydrodynamic Focusing
Jahn, A., Vreeland, W. N., Gaitan, M., & Locascio, L. E. (2004) · Journal of the American Chemical Society · doi:10.1021/ja0318030 · Cited by 537
Liposome Technology for Industrial Purposes
Wagner, A., & Vorauer-Uhl, K. (2011) · Journal of Drug Delivery · doi:10.1155/2011/591325 · Cited by 435
Microfluidic Mixing and the Formation of Nanoscale Lipid Vesicles
Jahn, A., Stavis, S. M., Hong, J. S., Vreeland, W. N., DeVoe, D. L., & Gaitan, M. (2010) · ACS Nano · doi:10.1021/nn901676x · Cited by 432
Bioprocess optimization using design-of-experiments methodology
Mandenius, C., & Brundin, A. (2008) · Biotechnology Progress · doi:10.1002/btpr.67 · Cited by 422
Microfluidic methods for forming liposomes
van Swaay, D., & deMello, A. (2013) · Lab on a Chip · doi:10.1039/c2lc41121k · Cited by 379
Singh, B., Kumar, R., & Ahuja, N. (2005) · Critical Reviews in Therapeutic Drug Carrier Systems · doi:10.1615/critrevtherdrugcarriersyst.v22.i1.20 · Cited by 352
Zhigaltsev, I. V., Belliveau, N., Hafez, I., Leung, A. K. K., Huft, J., Hansen, C., & Cullis, P. R. (2012) · Langmuir · doi:10.1021/la204833h · Cited by 345
Development of non-viral vectors for systemic gene delivery
Liu, F., & Huang, L. (2002) · Journal of Controlled Release · doi:10.1016/s0168-3659(01)00494-1 · Cited by 294 · cited 1×
“Depicted are the critical process parameters and the critical quality attributes. transfection efficiency and optimal immune response (McNeil et al., 2010; Liu and Huang, 2002) and was therefore chosen to allow correlation of the systems produced via this new production method with previous studies.”
MethodBiocompatible stabilizers in the preparation of PLGA nanoparticles: a factorial design study
Vandervoort, J., & Ludwig, A. (2002) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(02)00058-3 · Cited by 237
Multivariate methods in pharmaceutical applications
Gabrielsson, J., Lindberg, N., & Lundstedt, T. (2002) · Journal of Chemometrics · doi:10.1002/cem.697 · Cited by 221
Particle Size Distribution in DMPC Vesicles Solutions Undergoing Different Sonication Times
Maulucci, G., Spirito, M. D., Arcòvito, G., Boffi, F., Castellano, A. C., & Briganti, G. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.048876 · Cited by 175
Zook, J. M., & Vreeland, W. N. (2010) · Soft Matter · doi:10.1039/b923299k · Cited by 162 · cited 1×
“Previous work using hydrodynamic flow-focusing techniques have also reported the decrease in liposome size with the increase in FRR (Jahn et al., 2010; Zook and Vreeland, 2010), in agreement with results in this study.”
ResultFactors involved in the production of liposomes with a high-pressure homogenizer
Barnadas‐Rodríguez, R., & Sabés, M. (2001) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(00)00661-x · Cited by 117 · cited 2×
“, 1979), or high-pressure homogenization (Barnadas-Rodriguez and Sabes, 2001; Pupo et al., 2005).”
BackgroundLiposomes preparation methods.
Riaz, M. (1996) · PubMed · Cited by 113
Improved size-tunable preparation of polymeric nanoparticles by microfluidic nanoprecipitation
Gall, F. B., Garg, D. K., Serra, C. A., Hoarau, Y., Anton, N., Brochon, C., Parida, D., Vandamme, T., & Hadziioannou, G. (2012) · Polymer · doi:10.1016/j.polymer.2012.08.039 · Cited by 109 · cited 3×
“, 2012) and polymeric nanoparticles (Bally et al., 2012).”
BackgroundInfluentialKawaura, C., Noguchi, A., Furuno, T., & Nakanishi, M. (1998) · FEBS Letters · doi:10.1016/s0014-5793(97)01532-9 · Cited by 109
Pupo, E., Padrón, A., Santana, E., Sotolongo, J., Quintana, D., Dueñas, S., Duarte, C. A., de la Rosa, M. C., & Hardy, E. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.02.001 · Cited by 89
A facile microfluidic method for production of liposomes.
Pradhan, P. C., Guan, J., Lu, D., Wang, P. G., Lee, L. J., & Lee, R. J. (2008) · PubMed · Cited by 88
Davies, R. T., Kim, D., & Park, J. (2012) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/22/5/055003 · Cited by 68
Chemometrics applications in biotech processes: A review
Rathore, A. S., Bhushan, N., & Hadpe, S. R. (2011) · Biotechnology Progress · doi:10.1002/btpr.561 · Cited by 66
Transfection efficiency boost by designer multicomponent lipoplexes
Caracciolo, G., Pozzi, D., Caminiti, R., Marchini, C., Montani, M., Amici, A. R. D., & Amenitsch, H. W. (2007) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2007.06.027 · Cited by 60 · cited 1×
“The size, charge and lipid/NDA ration have previously been shown to effect transfection efficiency (Aljaberi et al., 2007; Caracciolo et al., 2007).”
BackgroundThe Application of Metabonomics as an Early In Vivo Toxicity Screen
Stevens, G. J., Deese, A. J., & Robertson, D. G. (2005) · CRC Press eBooks · doi:10.1201/b14117-9 · Cited by 51
Exploring the Correlation Between Lipid Packaging in Lipoplexes and Their Transfection Efficacy
Moghaddam, B., McNeil, S. E., Zheng, Q., Mohammed, A. R., & Perrie, Y. (2011) · Pharmaceutics · doi:10.3390/pharmaceutics3040848 · Cited by 41 · cited 1×
“Here, an equal molar lipid ratio was used, a standard ratio in cationic liposome-DNA transfection studies as reported previously (Felgner et al., 1994; Moghaddam et al., 2011).”
MethodSelf-citationAljaberi, A., Spelios, M. G., Kearns, M. D., Selvi, B., & Savva, M. (2007) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2007.01.012 · Cited by 29 · cited 1×
“The size, charge and lipid/NDA ration have previously been shown to effect transfection efficiency (Aljaberi et al., 2007; Caracciolo et al., 2007).”
Background양중석 (2015) · CHINESE LITERATURE · doi:10.21192/scll.83..201505.001 · Cited by 28
Nonviral Approaches for Cancer Gene Therapy
Huang, L., & Lui, V. W. Y. (2003) · CRC Press eBooks · doi:10.1201/9780203912331-14 · Cited by 2
Cited by
New developments in liposomal drug delivery
Pattni, B. S., Chupin, V. V., & Torchilin, V. P. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00046 · Cited by 1,600
Liposomes: Advancements and innovation in the manufacturing process
Shah, S., Dhawan, V., Holm, R., Nagarsenker, M. S., & Perrie, Y. (2020) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2020.07.002 · Cited by 745
Self-citationRecent advancements in liposome technology
Filipczak, N., Pan, J., Yalamarty, S. S. K., & Torchilin, V. P. (2020) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2020.06.022 · Cited by 592
Liposome production by microfluidics: potential and limiting factors
Carugo, D., Bottaro, E., Owen, J., Stride, E., & Nastruzzi, C. (2016) · Scientific Reports · doi:10.1038/srep25876 · Cited by 440
A comprehensive review on recent preparation techniques of liposomes
Has, C., & Sunthar, P. (2020) · Journal of Liposome Research · doi:10.1080/08982104.2019.1668010 · Cited by 357
Metadata
- Authors
- Kastner, E., Kaur, R., Lowry, D., Moghaddam, B., Wilkinson, A., & Perrie, Y.
- Venue
- International Journal of Pharmaceutics
- Publisher
- Elsevier BV
- Published
- 2014-12
- Volume
- 477
- Issue
- 1-2
- Pages
- 361-368
- ISSN
- 0378-5173 (ISSN-L)
- OpenAlex
- W2023976671
- Cited by
- 178
- References
- 41
- FWCI
- 4.47
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.