Dynamic modeling and characteristic analysis of a two-stage vapor injection heat pump system under frosting conditions
The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
This paper presents a distributed-parameter dynamic heat exchanger model integrated with a detailed frost growth model to account for non-uniform frost formation on a fan-supplied finned-tube coil. A novel, iteration-free approach is proposed to solve the air flow redistribution by linearizing a system of non-linear air pressure drop equalization equations, resulting in a significant improvement in the computational efficiency. As a continuation and extension of our previous work, the developed models along with the component models described in Qiao et al. (2015a) are applied for the first time to explore the frosting dynamics of a two-stage flash tank vapor injection heat pump system. It is found that frost formation degrades the heating performance of the system substantially. Meanwhile, the simulation indicates that air and refrigerant flow maldistribution, resulting from non-uniform frost growth on the outdoor heat exchanger, can lead to unstable system hunting behavior. Comparisons between the simulation results and experimental data indicate that the proposed models can reasonably predict the time-dependent heat transfer and fluid flow phenomena of the system.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Following Qiao et al. [7], the total water vapor mass flux ( ṁ”
From An analytical model of evaporator performance under frosting conditions for lumped-parameter simulations of heat pumps (2025) · cites this paper as [7]
In the citing paper
“The diffusion path of water vapor follows the pore volume in the porous frost layer, so the actual length of the diffusion path is longer than that of the path in free space for the same displacement, since the pore region is generally tortuous in the porous medium.Hence, the effective diffusion coefficient is redefined [7]:”
From An analytical model of evaporator performance under frosting conditions for lumped-parameter simulations of heat pumps (2025) · cites this paper as [7]
In the citing paper
“Quiao et al. [7] integrated the same frost formation model into a distributed-parameter dynamic heat exchanger model embedded in a two-stage vapor injection heat pump model.”
From An analytical model of evaporator performance under frosting conditions for lumped-parameter simulations of heat pumps (2025) · cites this paper as [7]
Citations
Cites
Kays, W. M., London, A. L., & Eckert, E. R. G. (1960) · Journal of Applied Mechanics · doi:10.1115/1.3644004 · Cited by 2,840
Analysis of heat and mass transfer
Eckert, E. R. G., & Drake, R. M. (1971) · Medical Entomology and Zoology · Cited by 1,993
Reference Fluid Thermodynamic and Transport Properties (REFPROP)
Lemmon, E. W. (2007) · Medical Entomology and Zoology · Cited by 990
Thermal environmental engineering
(1962) · Journal of the Franklin Institute · doi:10.1016/0016-0032(62)90922-5 · Cited by 930
(2017) · Elsevier eBooks · doi:10.1016/c2014-0-03422-3 · Cited by 818
Void Fractions in Two-Phase Flow: A Correlation Based upon an Equal Velocity Head Model
Smith, S. L. (1969) · Proceedings of the Institution of Mechanical Engineers · doi:10.1243/pime_proc_1969_184_051_02 · Cited by 451
A one-dimensional model for frost formation on a cold flat surface
Lee, K.-S., Kim, W.-S., & Lee, T.-H. (1997) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(97)00074-4 · Cited by 296
Two-stage heat pump system with vapor-injected scroll compressor using R410A as a refrigerant
Wang, X., Hwang, Y., & Radermacher, R. (2009) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2009.03.004 · Cited by 251
Self-citationYao, Y., Jiang, Y., Deng, S., & Ma, Z. (2004) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2004.03.013 · Cited by 196
Performance comparison of R410A and R32 in vapor injection cycles
Xu, X., Hwang, Y., & Radermacher, R. (2012) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2012.12.010 · Cited by 172
Self-citation
Cited by
Ma, L., Sun, Y., Wang, F., Wang, M., Zhang, S., & Wang, Z. (2025) · Applied Energy · doi:10.1016/j.apenergy.2024.124358 · Cited by 54
Wei, W., Feng, Z., Sun, Y., Wang, W., Jin, X., Zhang, J., & Dai, C. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.109327 · Cited by 51
Ma, J., Kim, D., Braun, J. E., & Horton, W. T. (2023) · Energy · doi:10.1016/j.energy.2023.127030 · Cited by 41
The frosting and soil imbalance performance issues of building heat pumps: An overview
Emmanuel, B., Zhou, J., Binama, M., Zhao, K., Abbas, S., & Yuan, Y. (2022) · Energy and Buildings · doi:10.1016/j.enbuild.2022.112387 · Cited by 50
Qiao, H., Aute, V., & Radermacher, R. (2018) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2017.12.017 · Cited by 46
Self-citationXiao, B., Tongyi, H., He, L., Yan, Y., Sun, Y., & Wang, W. (2018) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2018.11.026 · Cited by 35
Review on the two-stage vapor injection heat pump with a flash tank
Ceylan, H. (2023) · Engineering Science and Technology an International Journal · doi:10.1016/j.jestch.2023.101583 · Cited by 33
Sarmiento, A. P., de Sá Sarmiento, F. I. P., Shooshtari, A., & Ohadi, M. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2024.123680 · Cited by 29
Anti-frosting operation and regulation technology of air-water dual-source heat pump evaporator
Zhong, H., Li, Z., Long, J., Xia, K., Lu, H., & Yongga, A. (2022) · Energy · doi:10.1016/j.energy.2022.124393 · Cited by 23
Kim, D., Myeong, S., Cha, D., & Kim, Y. (2019) · Energy · doi:10.1016/j.energy.2019.115925 · Cited by 22
Yang, J., Lee, C.-Y., Muehlbauer, J., & Hwang, Y. (2025) · Energy · doi:10.1016/j.energy.2025.139262 · Cited by 15
Luo, W., Lai, J.-C., Hsieh, M.-C., & Huang, I.-H. (2020) · Sensors and Materials · doi:10.18494/sam.2020.3107 · Cited by 14
A reduced-order model for predicting transient performance of air-source heat pumps
Yousaf, S., Raza, S. M. M., Khan, A., & Bradshaw, C. R. (2026) · Applied Energy · doi:10.1016/j.apenergy.2026.127412 · Cited by 10
Intelligent High-performance Dynamic Control for Two-stage Screw High-temperature Heat Pump System
Luo, W., Lai, J.-C., Hsieh, P.-Y., & Fasya, F. R. (2018) · Sensors and Materials · doi:10.18494/sam.2018.2070 · Cited by 6
Ma, J., Kim, D., & Braun, J. E. (2023) · Linköping electronic conference proceedings · doi:10.3384/ecp2118626 · Cited by 3
“Within the context of complete cycle modeling considering the dynamics on both the refriger-ant side and air side, Qiao, Aute, and Radermacher (2017) integrated a one-dimensional frost growth model into an evaporator model coupled to other components of a two-stage flash tank vapor injection heat…”
BackgroundMethodNumerical model for liquid-to-liquid heat pumps implementing switching mode
Salazar-Herran, E., Martín-Escudero, K., Alleyne, A. G., del Portillo, L. A., & Romero-Antón, N. (2019) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2019.114054 · Cited by 3
Tube-fin Heat Exchanger Circuitry Optimization For Improved Performance Under Frosting Conditions
Li, Z., Qiao, H., & Aute, V. (2019) · Linköping electronic conference proceedings · doi:10.3384/ecp19157259 · Cited by 3
“(Qiao et al, 2017) observed that the tubes which the frost is the most likely to deposit on are the ones close to the refrigerant inlets with low HX surface temperature.”
BackgroundMethodSelf-citationSun, J., Zhu, D., Yin, Y., & Li, X. (2018) · Science China Technological Sciences · doi:10.1007/s11431-017-9237-6 · Cited by 3
Sedoni, R., Santangelo, P. E., Angeli, D., Romani, M., & Fioravanti, L. (2025) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/2940/1/012015 · Cited by 2
Lu, Z., Huang, R., & Woods, J. (2024) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Cited by 2
Sedoni, R., Santangelo, P. E., & Angeli, D. (2026) · Results in Engineering · doi:10.1016/j.rineng.2026.113465 · Cited by 1
Sedoni, R., Romani, M., Monteleone, W., Ochs, F., Angeli, D., & Santangelo, P. E. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5986001 · Cited by 1
Modellazione e analisi sperimentale di sistemi avanzati per la climatizzazione di ambienti confinati
Angeli, D., Santangelo, P. E., Zambonelli, F., & Sedoni, R. (2026) · IRIS UNIMORE (University of Modena and Reggio Emilia) · Cited by 1
Yousaf, S., Tanveer, M. M., & Bradshaw, C. R. (2026) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2026.106988 · Cited by 1
Chen, L., Wang, W. P., Yang, X. Y., Liu, H., & Ou, R. H. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4811410
Ikram, H., Alexander, A., & Bach, C. K. (2026) · Energy and Buildings · doi:10.1016/j.enbuild.2026.117945
Mei, Z. (2023) · University Libraries (University of Maryland) · doi:10.13016/dspace/rz74-jzrj
Bezyan, Y., Nasiri, F., & Nik‐Bakht, M. (2026) · Building and Environment · doi:10.1016/j.buildenv.2026.115033
The performance improvement and dynamic behavior of steam generation heat pump
강대훈 (2020) · Seoul National University Open Repository (Seoul National University)
Metadata
- Authors
- Qiao, H., Aute, V., & Radermacher, R.
- Affiliations
- Mitsubishi Electric Research Laboratories (United States) (US)
- University of Maryland, College Park (US)
- Corresponding author
- Qiao, Hongtao
- Venue
- International Journal of Refrigeration
- Publisher
- Elsevier BV
- Published
- 2017-12
- Volume
- 84
- Pages
- 181-197
- ISSN
- 0140-7007 (ISSN-L)
- OpenAlex
- W2752993862
- Semantic Scholar
- 1cf762a07c585f99c3dd733d5624055b1f9e0a00
- Cited by
- 29
- References
- 44
- Citations by year
- 2026: 6 · 2025: 3 · 2024: 5 · 2023: 4 · 2022: 2 · 2020: 2 · 2019: 3 · 2018: 4
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- International Journal of Refrigeration (publishedVersion)
- Funders
- University of Maryland
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Keywords
- frost growth, frost formation, hunting behavior, flow maldistribution, dynamic modeling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.