Dynamic modeling and characteristic analysis of a two-stage vapor injection heat pump system under frosting conditions
The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
This paper presents a distributed-parameter dynamic heat exchanger model integrated with a detailed frost growth model to account for non-uniform frost formation on a fan-supplied finned-tube coil. A novel, iteration-free approach is proposed to solve the air flow redistribution by linearizing a system of non-linear air pressure drop equalization equations, resulting in a significant improvement in the computational efficiency. As a continuation and extension of our previous work, the developed models along with the component models described in Qiao et al. (2015a) are applied for the first time to explore the frosting dynamics of a two-stage flash tank vapor injection heat pump system. It is found that frost formation degrades the heating performance of the system substantially. Meanwhile, the simulation indicates that air and refrigerant flow maldistribution, resulting from non-uniform frost growth on the outdoor heat exchanger, can lead to unstable system hunting behavior. Comparisons between the simulation results and experimental data indicate that the proposed models can reasonably predict the time-dependent heat transfer and fluid flow phenomena of the system.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Following Qiao et al. [7], the total water vapor mass flux ( ṁ”
From An analytical model of evaporator performance under frosting conditions for lumped-parameter simulations of heat pumps (2025) · cites this paper as [7]
In the citing paper
“The diffusion path of water vapor follows the pore volume in the porous frost layer, so the actual length of the diffusion path is longer than that of the path in free space for the same displacement, since the pore region is generally tortuous in the porous medium.Hence, the effective diffusion coefficient is redefined [7]:”
From An analytical model of evaporator performance under frosting conditions for lumped-parameter simulations of heat pumps (2025) · cites this paper as [7]
In the citing paper
“Quiao et al. [7] integrated the same frost formation model into a distributed-parameter dynamic heat exchanger model embedded in a two-stage vapor injection heat pump model.”
From An analytical model of evaporator performance under frosting conditions for lumped-parameter simulations of heat pumps (2025) · cites this paper as [7]
Citations
Cites
Kays, W. M., London, A. L., & Eckert, E. R. G. (1960) · Journal of Applied Mechanics · doi:10.1115/1.3644004 · Cited by 2,840
Analysis of heat and mass transfer
Eckert, E. R. G., & Drake, R. M. (1971) · Medical Entomology and Zoology · Cited by 1,993
Reference Fluid Thermodynamic and Transport Properties (REFPROP)
Lemmon, E. W. (2007) · Medical Entomology and Zoology · Cited by 990
Thermal environmental engineering
(1962) · Journal of the Franklin Institute · doi:10.1016/0016-0032(62)90922-5 · Cited by 930
(2017) · Elsevier eBooks · doi:10.1016/c2014-0-03422-3 · Cited by 818
Void Fractions in Two-Phase Flow: A Correlation Based upon an Equal Velocity Head Model
Smith, S. L. (1969) · Proceedings of the Institution of Mechanical Engineers · doi:10.1243/pime_proc_1969_184_051_02 · Cited by 451
A one-dimensional model for frost formation on a cold flat surface
Lee, K.-S., Kim, W.-S., & Lee, T.-H. (1997) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(97)00074-4 · Cited by 296
Two-stage heat pump system with vapor-injected scroll compressor using R410A as a refrigerant
Wang, X., Hwang, Y., & Radermacher, R. (2009) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2009.03.004 · Cited by 251
Self-citationYao, Y., Jiang, Y., Deng, S., & Ma, Z. (2004) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2004.03.013 · Cited by 196
Performance comparison of R410A and R32 in vapor injection cycles
Xu, X., Hwang, Y., & Radermacher, R. (2012) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2012.12.010 · Cited by 172
Self-citationExperimental study of a heat pump system with flash-tank coupled with scroll compressor
Ma, G., & Zhao, H. H. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2007.05.003 · Cited by 155
Seker, D., Karatas, H., & Egrican, N. (2004) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2003.12.003 · Cited by 147
Calculation of Fin Efficiency for Wet and Dry Fins
Hong, K. T., & Webb, R. L. (1996) · HVAC&R Research · doi:10.1080/10789669.1996.10391331 · Cited by 146
Analysis and optimization of subcritical two-stage vapor injection heat pump systems
Redón, A., Navarro-Peris, E., Pitarch, M., Gonzálvez-Maciá, J., & Corberán, J. M. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.02.066 · Cited by 141
Heo, J., Jeong, M. W., & Kim, Y. (2010) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2009.12.021 · Cited by 127
Transient modeling of a flash tank vapor injection heat pump system – Part I: Model development
Qiao, H.-T., Aute, V., & Radermacher, R. (2015) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2014.06.019 · Cited by 125
Self-citationShao, L.-L., Yang, L., & Zhang, C.-L. (2010) · Applied Energy · doi:10.1016/j.apenergy.2009.08.021 · Cited by 112
(1974) · Cited by 107
Modeling for predicting frosting behavior of a fin–tube heat exchanger
Yang, D.-K., Lee, K.-S., & Song, S. (2006) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2005.09.022 · Cited by 94
Thermodynamic analyses on an ejector enhanced CO2 transcritical heat pump cycle with vapor-injection
Bai, T., Yan, G. F., & Yu, J. (2015) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2015.04.010 · Cited by 91
Qi, H., Liu, F., & Yu, J. (2016) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2016.11.024 · Cited by 87
Experiment study of an enhanced vapor injection refrigeration/heat pump system using R32
Xu, S., Guoyuan, M., Liu, Q., & Zhongliang, L. (2013) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2012.12.014 · Cited by 80
Tso, C. P., Cheng, Y. C., & Lai, A. C. K. (2006) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2005.04.009 · Cited by 75
Ye, H.-Y., & Lee, K.-S. (2013) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2013.08.026 · Cited by 70
First-principles modeling of frost accumulation on fan-supplied tube-fin evaporators
da Silva, D. L., Hermes, C. J. L., & Melo, C. (2011) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2011.04.029 · Cited by 70
Baek, C., Heo, J., Jung, J., Lee, E., & Kim, Y. (2014) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2014.03.009 · Cited by 70
Dangelo, J. V. H., Aute, V., & Radermacher, R. (2016) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2016.01.019 · Cited by 69
Self-citationKnabben, F. T., Hermes, C. J. L., & Melo, C. (2011) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2011.07.006 · Cited by 67
Modeling non-uniform frost growth on a fin-and-tube heat exchanger
Padhmanabhan, S. K., Fisher, D. E., Cremaschi, L., & Moallem, E. (2011) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2011.06.005 · Cited by 66
Fan supplied heat exchanger fin performance under frosting conditions
Chen, H., Thomas, L., & Besant, R. W. (2003) · International Journal of Refrigeration · doi:10.1016/s0140-7007(02)00011-7 · Cited by 59
Qiao, H., Xu, X., Aute, V., & Radermacher, R. (2014) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2014.06.018 · Cited by 53
Self-citationRoh, C. W., & Kim, M. S. (2011) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2011.10.013 · Cited by 42
An advanced switching moving boundary heat exchanger model with pressure drop
Qiao, H., Laughman, C. R., Aute, V., & Radermacher, R. (2016) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2016.01.026 · Cited by 40
Self-citationDynamic characteristics of an air-to-water heat pump under frosting/defrosting conditions
Huang, D., He, Z., & Yuan, X. L. (2006) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2006.12.003 · Cited by 39
Borges, B. N., Melo, C., & Hermes, C. J. L. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.01.089 · Cited by 39
PERFORMANCE INVESTIGATION OF TWO-STAGE HEAT PUMP SYSTEM WITH VAPOR-INJECTED SCROLL COMPRESSOR
Wang, X. (2008) · University Libraries (University of Maryland) · Cited by 39
Lenic, K., Trp, A., & Frankovic, B. (2009) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2008.12.030 · Cited by 38
Getu, H. M., & Bansal, P. K. (2007) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2007.02.003 · Cited by 36
Gong, J., Gao, T., Yuan, X., & Huang, D. (2008) · Energy Conversion and Management · doi:10.1016/j.enconman.2007.11.004 · Cited by 30
Modeling of a fan-supplied flat-tube heat exchanger exposed to non-uniform frost growth
Breque, F., & Nemer, M. (2017) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2016.12.012 · Cited by 21
Ribeiro, R. S., & Hermes, C. J. L. (2014) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2014.05.012 · Cited by 19
Modeling the airside dynamic behavior of a heat exchanger under frosting conditions
Gao, T., & Gong, J. (2011) · Journal of Mechanical Science and Technology · doi:10.1007/s12206-011-0615-5 · Cited by 18
On the influence of state selection on mass conservation in dynamic vapour compression cycle models
Laughman, C. R., & Qiao, H. (2017) · Mathematical and Computer Modelling of Dynamical Systems · doi:10.1080/13873954.2017.1298625 · Cited by 15
Self-citationA new dynamic heat pump simulation model with variable speed compressors under frosting conditions
Park, N., Shin, J., & Chung, B. (2013) · Elsevier eBooks · doi:10.1533/9781782421702.12.681 · Cited by 14
Cited by
Ma, L., Sun, Y., Wang, F., Wang, M., Zhang, S., & Wang, Z. (2025) · Applied Energy · doi:10.1016/j.apenergy.2024.124358 · Cited by 54
Wei, W., Feng, Z., Sun, Y., Wang, W., Jin, X., Zhang, J., & Dai, C. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.109327 · Cited by 51
Ma, J., Kim, D., Braun, J. E., & Horton, W. T. (2023) · Energy · doi:10.1016/j.energy.2023.127030 · Cited by 41
The frosting and soil imbalance performance issues of building heat pumps: An overview
Emmanuel, B., Zhou, J., Binama, M., Zhao, K., Abbas, S., & Yuan, Y. (2022) · Energy and Buildings · doi:10.1016/j.enbuild.2022.112387 · Cited by 50
Qiao, H., Aute, V., & Radermacher, R. (2018) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2017.12.017 · Cited by 46
Self-citation
Metadata
- Authors
- Qiao, H., Aute, V., & Radermacher, R.
- Affiliations
- Mitsubishi Electric Research Laboratories (United States) (US)
- University of Maryland, College Park (US)
- Corresponding author
- Qiao, Hongtao
- Venue
- International Journal of Refrigeration
- Publisher
- Elsevier BV
- Published
- 2017-12
- Volume
- 84
- Pages
- 181-197
- ISSN
- 0140-7007 (ISSN-L)
- OpenAlex
- W2752993862
- Semantic Scholar
- 1cf762a07c585f99c3dd733d5624055b1f9e0a00
- Cited by
- 29
- References
- 44
- Citations by year
- 2026: 6 · 2025: 3 · 2024: 5 · 2023: 4 · 2022: 2 · 2020: 2 · 2019: 3 · 2018: 4
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- International Journal of Refrigeration (publishedVersion)
- Funders
- University of Maryland
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Keywords
- frost growth, frost formation, hunting behavior, flow maldistribution, dynamic modeling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.