The DOI matches its Crossref record; 82 of the 82 references it cites were found in a registry or an index.
Medical applications of infrared thermography: A review
Open accessAbstract
Abnormal body temperature is a natural indicator of illness. Infrared thermography (IRT) is a fast, passive, non-contact and non-invasive alternative to conventional clinical thermometers for monitoring body temperature. Besides, IRT can also map body surface temperature remotely. Last five decades witnessed a steady increase in the utility of thermal imaging cameras to obtain correlations between the thermal physiology and skin temperature. IRT has been successfully used in diagnosis of breast cancer, diabetes neuropathy and peripheral vascular disorders. It has also been used to detect problems associated with gynecology, kidney transplantation, dermatology, heart, neonatal physiology, fever screening and brain imaging. With the advent of modern infrared cameras, data acquisition and processing techniques, it is now possible to have real time high resolution thermographic images, which is likely to surge further research in this field. The present efforts are focused on automatic analysis of temperature distribution of regions of interest and their statistical analysis for detection of abnormalities. This critical review focuses on advances in the area of medical IRT. The basics of IRT, essential theoretical background, the procedures adopted for various measurements and applications of IRT in various medical fields are discussed in this review. Besides background information is provided for beginners for better understanding of the subject.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2013) · Elsevier eBooks · doi:10.1016/c2010-0-65874-3 · Cited by 5,025
Analysis of Tissue and Arterial Blood Temperatures in the Resting Human Forearm
Pennes, H. H. (1948) · Journal of Applied Physiology · doi:10.1152/jappl.1948.1.2.93 · Cited by 4,646
Analysis of Tissue and Arterial Blood Temperatures in the Resting Human Forearm
Pennes, H. H. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.1.5 · Cited by 3,982
Theory and Practice of Infrared Technology for Nondestructive Testing
Maldague, X. (2001) · Cited by 1,657
Rajic, N. (2002) · Composite Structures · doi:10.1016/s0263-8223(02)00161-7 · Cited by 701
A reappraisal of the use of infrared thermal image analysis in medicine
Jones, B. F. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.746635 · Cited by 572
A review of thermography as promising non-invasive detection modality for breast tumor
Ng, E. Y.-K. (2009) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2008.06.015 · Cited by 448
Webb, S. (1997) · Radiography · doi:10.1016/s1078-8174(97)90040-7 · Cited by 435
Preventing Diabetic Foot Ulcer Recurrence in High-Risk Patients
Lavery, L. A., Higgins, K. R., Lanctot, D. R., Constantinides, G. P., Zamorano, R. G., Athanasiou, K. A., Armstrong, D. G., & Agrawal, C. M. (2007) · Diabetes Care · doi:10.2337/dc06-1600 · Cited by 434
Spectral emissivity of skin and pericardium
Steketee, J. (1973) · Physics in Medicine & Biology · doi:10.1088/0031-9155/18/5/307 · Cited by 429
Arora, N., Martins, D., Ruggerio, D., Tousimis, E., Swistel, A. J., Osborne, M. P., & Simmons, R. M. (2008) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2008.06.015 · Cited by 320
Digital infrared thermal imaging of human skin
Jones, B. F., & Plassmann, P. (2002) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2002.1175137 · Cited by 287
(2002) · Mechanical engineering series · doi:10.1201/9781420041064.ch4 · Cited by 285
A perspective on medical infrared imaging
Jiang, L. J., Ng, E. Y. K., Yeo, A. C. B., Wu, S., Pan, F., Yau, W. Y., Chen, J. H., & Yang, Y. (2005) · Journal of Medical Engineering & Technology · doi:10.1080/03091900512331333158 · Cited by 283
A Comparative Review of Thermography as a Breast Cancer Screening Technique
Kennedy, D. A., Lee, T., & Seely, D. (2009) · Integrative Cancer Therapies · doi:10.1177/1534735408326171 · Cited by 283
Diakides, N. A., & Bronzino, J. D. (2007) · CRC Press eBooks · doi:10.1201/9781420008340 · Cited by 268
Barnes, R. B. (1963) · Science · doi:10.1126/science.140.3569.870 · Cited by 227
Infrared thermal imaging for detection of peripheral vascular disorders
Philip, J., Bagavathiappan, S., Saravanan, T., Jayakumar, T., Raj, B., Karunanithi, R., Panicker, T. M. R., Korath, M., & Jagadeesan, K. (2009) · Journal of Medical Physics · doi:10.4103/0971-6203.48720 · Cited by 204
Self-citationBagavathiappan, S., Philip, J., Jayakumar, T., Raj, B., Rao, P. N. S., Varalakshmi, M., & Mohan, V. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400613 · Cited by 204
Self-citationInfrared thermography on ocular surface temperature: A review
Tan, J.-H., Ng, E. Y. K., Rajendra Acharya, U., & Chee, C. (2009) · Infrared Physics & Technology · doi:10.1016/j.infrared.2009.05.002 · Cited by 201
Houdas, Y., & Ring, E. F. J. (1982) · Springer eBooks · doi:10.1007/978-1-4899-0345-7 · Cited by 199
Surveillance and outbreak reports
Atkin, S., Anaraki, S., Gothard, P., Walsh, A., Brown, D. B., Gopal, R., Morgan, D., Gobbi, F. G., Napoletano, G., Piovesan, C., et al. (2009) · Eurosurveillance · Cited by 191
An Operational Near-Infrared Fluorescence Imaging System Prototype for Large Animal Surgery
De Grand, A. M., & Frangioni, J. V. (2003) · Technology in Cancer Research & Treatment · doi:10.1177/153303460300200607 · Cited by 189
Analysis of IR thermal imager for mass blind fever screening
Ng, E. Y. K., Kawb, G. J. L., & Chang, W. M. (2004) · Microvascular Research · doi:10.1016/j.mvr.2004.05.003 · Cited by 182
The historical development of temperature measurement in medicine
Ring, E. F. J. (2006) · Infrared Physics & Technology · doi:10.1016/j.infrared.2006.06.029 · Cited by 172
Thermal Imaging Today and Its Relevance to Diabetes
Ring, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400414 · Cited by 167
Infrared thermal imaging: A review of the literature and case report
Kateb, B., Yamamoto, V., Yu, C., Grundfest, W., & Gruen, J. P. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.03.043 · Cited by 165
Fever screening during the influenza (H1N1-2009) pandemic at Narita International Airport, Japan
Nishiura, H., & Kamiya, K. (2011) · BMC Infectious Diseases · doi:10.1186/1471-2334-11-111 · Cited by 159
Bharara, M., Cobb, J. E., & Claremont, D. J. (2006) · The International Journal of Lower Extremity Wounds · doi:10.1177/1534734606293481 · Cited by 156
Comparison of 3 Infrared Thermal Detection Systems and Self-Report for Mass Fever Screening
Nguyen, A. V., Cohen, N. J., Lipman, H., Brown, C. M., Molinari, N., Jackson, W. L., Kirking, H. L., Szymanowski, P., Wilson, T. W., Salhi, B. A., et al. (2010) · Emerging infectious diseases · doi:10.3201/eid1611.100703 · Cited by 152
Bitar, D., Goubar, A., & Desenclos, J. C. (2009) · Eurosurveillance · doi:10.2807/ese.14.06.19115-en · Cited by 150
Visualization of body thermoregulation by infrared imaging
Bouzida, N., Bendada, A., & Maldague, X. (2008) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2008.11.008 · Cited by 147
THE RADIATION OF HEAT FROM THE HUMAN BODY
Hardy, J. D. (1934) · Journal of Clinical Investigation · doi:10.1172/jci100607 · Cited by 137
Determination of Normal Ear Temperature with an Infrared Emission Detection Thermometer
CHAMBERLAIN, J., Terndrup, T. E., ALEXANDER, D., Silverstone, F. A., Wolf‐Klein, G. P., ODONNELL, R., & Grandner, J. (1995) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(95)70349-7 · Cited by 135
THE RADIATION OF HEAT FROM THE HUMAN BODY
Hardy, J. D. (1934) · Journal of Clinical Investigation · doi:10.1172/jci100609 · Cited by 133
Collins, A. J., Ring, E. F. J., Cosh, J., et al. (1974) · Annals of the Rheumatic Diseases · doi:10.1136/ard.33.2.113 · Cited by 131
Risk Factors in the Diabetic Foot
Sims, D. S., Cavanagh, P. R., & Ulbrecht, J. S. (1988) · Physical Therapy · doi:10.1093/ptj/68.12.1887 · Cited by 130
Hardy, J. D., & Muschenheim, C. (1934) · Journal of Clinical Investigation · doi:10.1172/jci100624 · Cited by 127
TAN, T., Quek, C. H., Ng, G. S., & Ng, E. Y. K. (2006) · Expert Systems with Applications · doi:10.1016/j.eswa.2006.06.012 · Cited by 119
Vaǐner, B. G. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/23/r01 · Cited by 117
The use of thermal imaging in assessing skin temperature following cryotherapy: a review
Costello, J. T., McInerney, C. D., Bleakley, C., Selfe, J., & Donnelly, A. (2011) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2011.11.008 · Cited by 117
Thermal discrimination thresholds in normal subjects and in patients with diabetic neuropathy.
Bertelsmann, F. W., Heimans, J. J., Weber, E. J. M., van der Veen, E. A., & Schouten, J. A. (1985) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.48.7.686 · Cited by 116
Monique Ernst, D., & Lee, M. H. M. (1985) · Pain · doi:10.1016/0304-3959(85)90073-9 · Cited by 115
Symmetry of Skin Temperature Comparing One Side of the Body to the other
Uematsu, S. (1985) · Cited by 112
Infrared Thermography to Mass-Screen Suspected Sars Patients with Fever
Chiu, W.-T., Lin, P.-W., Chiou, H., Lee, W.-S., Lee, C. N., Yang, Y., Lee, H. M., Hsieh, M. S., Hu, C., Ho, Y., et al. (2005) · Asia Pacific Journal of Public Health · doi:10.1177/101053950501700107 · Cited by 111
Thermography and the possibilities for its applications in clinical and experimental dermatology
Carlo, A. D. (1995) · Clinics in Dermatology · doi:10.1016/0738-081x(95)00073-o · Cited by 107
Relationship of skin temperature to sympathetic dysfunction in diabetic at-risk feet
Sun, P.-C., Lin, H.-D., Jao, S.-H. E., et al. (2006) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2005.12.012 · Cited by 106
The Technique of Infrared Imaging in Medicine
Boonsuk, W., & Hongma, P. (2022) · Journal of Applied Science · doi:10.14416/j.appsci.2022.02.004 · Cited by 103
New standards for devices used for the measurement of human body temperature
Ring, E. F. J., McEvoy, H. C., Jung, A., Żuber, J., & Machin, G. (2010) · Journal of Medical Engineering & Technology · doi:10.3109/03091901003663836 · Cited by 100
On the Temperature in Diseases: A Manual of Medical Thermometry
Wunderlich, C., & Woodman, W. B. (2010) · Cited by 99
Numerical computation as a tool to aid thermographic interpretation
Ng, N. M. S. E. Y. K. (2001) · Journal of Medical Engineering & Technology · doi:10.1080/03091900110043621 · Cited by 97
Advanced integrated technique in breast cancer thermography
Ng, E. Y. K., & Kee, E. (2008) · Journal of Medical Engineering & Technology · doi:10.1080/03091900600562040 · Cited by 93
Regression of capillary network in atrophied soleus muscle induced by hindlimb unweighting
Fujino, H., Kohzuki, H., Takeda, I., Kiyooka, T., Miyasaka, T., Mohri, S., Shimizu, J., & Kajiya, F. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00961.2004 · Cited by 90
Chiang, M., Lin, P.-W., Lin, L., Chiou, H., Chien, C.-W., Chu, S.-F., & Chiu, W. T. (2008) · Journal of the Formosan Medical Association · doi:10.1016/s0929-6646(09)60017-6 · Cited by 88
Is thermal scanner losing its bite in mass screening of fever due to SARS?
Ng, E. Y. ‐. (2005) · Medical Physics · doi:10.1118/1.1819532 · Cited by 86
Intraoperative infrared imaging of brain tumors
Gorbach, A. M., Heiss, J. D., Kopylev, L., & Oldfield, E. H. (2004) · Journal of neurosurgery · doi:10.3171/jns.2004.101.6.0960 · Cited by 84
Fever screening and infrared thermal imaging: concerns and guidelines
Mercer, J. B., Francis, E. K., & Ring, J. (2009) · Cited by 84
Ring, E. F., Collins, A. J., Bacon, P. A., & Cosh, J. A. (1974) · Annals of the Rheumatic Diseases · doi:10.1136/ard.33.4.353 · Cited by 79
Thermoregulation and Thermography in Neonatal Physiology and Disease
Dail, R. B., Guenther, B. D., & Rice, H. E. (2011) · Biological Research For Nursing · doi:10.1177/1099800411403467 · Cited by 78
Normalized methodology for medical infrared imaging
VARGAS, J. V. C., Brioschi, M. L., Dias, F., Parolin, M. B., Mulinari‐Brenner, F., Ordóñez, J. C., & Colman, D. (2008) · Infrared Physics & Technology · doi:10.1016/j.infrared.2008.11.003 · Cited by 77
Intracoronary Thermography for Detection of High-Risk Vulnerable Plaques
Madjid, M., Willerson, J. T., & Casscells, S. W. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.050 · Cited by 75
Bharara, M., Schoess, J. N., & Armstrong, D. G. (2012) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.2231 · Cited by 74
Thermology and facial telethermography. Part I: History and technical review
Anbar, M., Gratt, B. M., & Hong, D. (1998) · Dentomaxillofacial Radiology · doi:10.1038/sj.dmfr.4600314 · Cited by 71
Wu, C.-L., Yu, K., Chuang, H., Huang, M., Chen, T., & Chen, C. (2009) · Journal of Manipulative and Physiological Therapeutics · doi:10.1016/j.jmpt.2009.03.002 · Cited by 66
RADIATION OF HEAT FROM THE HUMAN BODY. V. THE TRANSMISSION OF INFRA-RED RADIATION THROUGH SKIN
Hardy, J. D., & Muschenheim, C. (1936) · Journal of Clinical Investigation · doi:10.1172/jci100746 · Cited by 66
Functional imaging of the brain by infrared radiation (thermoencephaloscopy)
Shevelev, I. A. (1998) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00038-0 · Cited by 66
Hirschl, M., Katzenschlager, R., Francesconi, C. M., & Kundi, M. (2004) · PubMed · Cited by 66
Quantitative Dynamic Telethermometry in Medical Diagnosis and Management
Anbar, M. (1994) · Medical Entomology and Zoology · Cited by 63
Mercer, J. B., Nielsen, S. P., & Hoffmann, G. (2008) · Europe PMC (PubMed Central) · Cited by 58
Non-contact infrared thermometry temperature measurement for screening fever in children
Ng, D. K., Chan, C., Lee, R. S., & Leung, L. C. K. (2005) · Annals of Tropical Paediatrics · doi:10.1179/146532805x72412 · Cited by 58
Arora, I. (2008) · Cited by 58
Investigation of peripheral vascular disorders using thermal imaging
Bagavathiappan, S., Saravanan, T., Philip, J., et al. (2008) · The British Journal of Diabetes · doi:10.1177/14746514080080020901 · Cited by 54
Self-citationKosus, N., Kosus, A., Duran, M., Simavli, S., & Turhan, N. (2010) · Journal of the Turkish-German Gynecological Association · doi:10.5152/jtgga.2010.24 · Cited by 49
Meridians in acupuncture and infrared imaging
Lo, S.-Y. (2002) · Medical Hypotheses · doi:10.1054/mehy.2001.1453 · Cited by 44
Detecting Fever in Polish Children by Infrared Thermography
Ring, E. F. J., Jung, A., Żuber, J., Rutkowski, P., Kalicki, B., & Bajwa, U. (2008) · International Conference on Quantitative InfraRed Thermography (QIRT) · doi:10.21611/qirt.2008.03_07_17 · Cited by 42
Thermal imaging in the detection of bowel ischemia
Brooks, J. P., Perry, W. B., Putnam, A. T., et al. (2000) · Diseases of the Colon & Rectum · doi:10.1007/bf02237446 · Cited by 40
Assessment of rheumatoid inflammation in the knee joint. A reappraisal.
Paterson, J., Watson, W. S., Teasdale, E., Evans, A. L., Newman, P., James, W. B., & Pitkeathly, D. A. (1978) · Annals of the Rheumatic Diseases · doi:10.1136/ard.37.1.48 · Cited by 34
Evaluation of thermal load during laser corneal refractive surgery using infrared thermography
Brunsmann, U., Sauer, U., Arba‐Mosquera, S., Magnago, T., & Triefenbach, N. (2010) · Infrared Physics & Technology · doi:10.1016/j.infrared.2010.06.003 · Cited by 29
Analysis and diagnosis of basal cell carcinoma (BCC) via infrared imaging
Flores-Sahagun, J. H., VARGAS, J. V. C., & Mulinari‐Brenner, F. (2011) · Infrared Physics & Technology · doi:10.1016/j.infrared.2011.05.002 · Cited by 23
Hoffmann, G., Nielsen, S. P., & Mercer, J. B. (2008) · NORA - Norwegian Open Research Archives · Cited by 23
Practical and dosimetric implications of a new type of packaging for radiographic film
Gillis, S., & Wagter, C. D. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/8/n01 · Cited by 9
Arnold, M. H., Preston, S., Beller, E., et al. (1989) · Clinical Rheumatology · doi:10.1007/bf02030078 · Cited by 6
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Infrared Thermography for Temperature Measurement and Non-Destructive Testing
Usamentiaga, R., Venegas, P., Guerediaga, J., Vega, L., Molleda, J., & Bulnes, F. (2014) · Sensors · doi:10.3390/s140712305 · Cited by 1,181
Infrared thermography for condition monitoring – A review
Bagavathiappan, S., Lahiri, B. B., Saravanan, T., Philip, J., & Jayakumar, T. (2013) · Infrared Physics & Technology · doi:10.1016/j.infrared.2013.03.006 · Cited by 979
Self-citationThermal cameras and applications: A survey
Gade, R., & Moeslund, T. B. (2014) · Machine Vision and Applications · doi:10.1007/s00138-013-0570-5 · Cited by 780
Classification of factors influencing the use of infrared thermography in humans: A review
Fernández-Cuevas, I., Bouzas Marins, J. C., Arnáiz Lastras, J., Gómez Carmona, P. M., Piñonosa Cano, S., García-Concepción, M. Á., & Sillero-Quintana, M. (2015) · Infrared Physics & Technology · doi:10.1016/j.infrared.2015.02.007 · Cited by 586
Metadata
- Authors
- Lahiri, B. B., Bagavathiappan, S., Jayakumar, T., & Philip, J.
- Venue
- Infrared Physics & Technology
- Publisher
- Elsevier BV
- Published
- 2012-07
- Volume
- 55
- Issue
- 4
- Pages
- 221-235
- ISSN
- 1350-4495 (ISSN-L)
- OpenAlex
- W2077332544
- Cited by
- 1,333
- References
- 82
- FWCI
- 26.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.