The DOI matches its Crossref record; 82 of the 82 references it cites were found in a registry or an index.
Medical applications of infrared thermography: A review
Open accessAbstract
Abnormal body temperature is a natural indicator of illness. Infrared thermography (IRT) is a fast, passive, non-contact and non-invasive alternative to conventional clinical thermometers for monitoring body temperature. Besides, IRT can also map body surface temperature remotely. Last five decades witnessed a steady increase in the utility of thermal imaging cameras to obtain correlations between the thermal physiology and skin temperature. IRT has been successfully used in diagnosis of breast cancer, diabetes neuropathy and peripheral vascular disorders. It has also been used to detect problems associated with gynecology, kidney transplantation, dermatology, heart, neonatal physiology, fever screening and brain imaging. With the advent of modern infrared cameras, data acquisition and processing techniques, it is now possible to have real time high resolution thermographic images, which is likely to surge further research in this field. The present efforts are focused on automatic analysis of temperature distribution of regions of interest and their statistical analysis for detection of abnormalities. This critical review focuses on advances in the area of medical IRT. The basics of IRT, essential theoretical background, the procedures adopted for various measurements and applications of IRT in various medical fields are discussed in this review. Besides background information is provided for beginners for better understanding of the subject.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2013) · Elsevier eBooks · doi:10.1016/c2010-0-65874-3 · Cited by 5,025
Analysis of Tissue and Arterial Blood Temperatures in the Resting Human Forearm
Pennes, H. H. (1948) · Journal of Applied Physiology · doi:10.1152/jappl.1948.1.2.93 · Cited by 4,646
Analysis of Tissue and Arterial Blood Temperatures in the Resting Human Forearm
Pennes, H. H. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.1.5 · Cited by 3,982
Theory and Practice of Infrared Technology for Nondestructive Testing
Maldague, X. (2001) · Cited by 1,657
Rajic, N. (2002) · Composite Structures · doi:10.1016/s0263-8223(02)00161-7 · Cited by 701
A reappraisal of the use of infrared thermal image analysis in medicine
Jones, B. F. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.746635 · Cited by 572
A review of thermography as promising non-invasive detection modality for breast tumor
Ng, E. Y.-K. (2009) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2008.06.015 · Cited by 448
Webb, S. (1997) · Radiography · doi:10.1016/s1078-8174(97)90040-7 · Cited by 435
Preventing Diabetic Foot Ulcer Recurrence in High-Risk Patients
Lavery, L. A., Higgins, K. R., Lanctot, D. R., Constantinides, G. P., Zamorano, R. G., Athanasiou, K. A., Armstrong, D. G., & Agrawal, C. M. (2007) · Diabetes Care · doi:10.2337/dc06-1600 · Cited by 434
Spectral emissivity of skin and pericardium
Steketee, J. (1973) · Physics in Medicine & Biology · doi:10.1088/0031-9155/18/5/307 · Cited by 429
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Infrared Thermography for Temperature Measurement and Non-Destructive Testing
Usamentiaga, R., Venegas, P., Guerediaga, J., Vega, L., Molleda, J., & Bulnes, F. (2014) · Sensors · doi:10.3390/s140712305 · Cited by 1,181
Infrared thermography for condition monitoring – A review
Bagavathiappan, S., Lahiri, B. B., Saravanan, T., Philip, J., & Jayakumar, T. (2013) · Infrared Physics & Technology · doi:10.1016/j.infrared.2013.03.006 · Cited by 979
Self-citationThermal cameras and applications: A survey
Gade, R., & Moeslund, T. B. (2014) · Machine Vision and Applications · doi:10.1007/s00138-013-0570-5 · Cited by 780
Classification of factors influencing the use of infrared thermography in humans: A review
Fernández-Cuevas, I., Bouzas Marins, J. C., Arnáiz Lastras, J., Gómez Carmona, P. M., Piñonosa Cano, S., García-Concepción, M. Á., & Sillero-Quintana, M. (2015) · Infrared Physics & Technology · doi:10.1016/j.infrared.2015.02.007 · Cited by 586
Non-destructive testing and evaluation of composite materials/structures: A state-of-the-art review
Wang, B., Zhong, S., Lee, T.-L., Fancey, K. S., & Mi, J. (2020) · Advances in Mechanical Engineering · doi:10.1177/1687814020913761 · Cited by 581
Infrared thermography (IRT) applications for building diagnostics: A review
Kylili, A., Fokaides, P. A., Christou, P., & Kalogirou, S. A. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.08.005 · Cited by 526
Pang, Q., Lou, D., Li, S., Wang, G., Qiao, B., Dong, S., Ma, L., Gao, C., & Wu, Z. (2020) · Advanced Science · doi:10.1002/advs.201902673 · Cited by 490
Adegboye, M. A., Fung, W.-K., & Karnik, A. (2019) · Sensors · doi:10.3390/s19112548 · Cited by 489
Non-destructive testing and evaluation of composite materials/structures: A state-of-the-art review
Wang, B., Zhong, S., Lee, T.-L., Fancey, K. S., & Mi, J. (2019) · Apollo (University of Cambridge) · doi:10.17863/cam.51343 · Cited by 444
Beyond the Visible: Bioinspired Infrared Adaptive Materials
Yang, J., Zhang, X., Zhang, X., Wang, L., Feng, W., & Li, Q. (2021) · Advanced Materials · doi:10.1002/adma.202004754 · Cited by 415
Analyses of internal structures and defects in materials using physics-informed neural networks
Zhang, E., Dao, M., Karniadakis, G. E., & Suresh, S. (2022) · Science Advances · doi:10.1126/sciadv.abk0644 · Cited by 393
Yakunin, S., Benin, B. M., Shynkarenko, Y., Nazarenko, O., Bodnarchuk, M. I., Dirin, D. N., Hofer, C., Cattaneo, S., & Kovalenko, M. V. (2019) · Nature Materials · doi:10.1038/s41563-019-0416-2 · Cited by 366
In Vivo Luminescence Nanothermometry: from Materials to Applications
del Rosal, B., Ximendes, E., Rocha, U., & Jaque, D. (2017) · Advanced Optical Materials · doi:10.1002/adom.201600508 · Cited by 331
Zaki, A., Chai, H., Aggelis, D., & Alver, N. (2015) · Sensors · doi:10.3390/s150819069 · Cited by 291
Light Emission of Self‐Trapped Excitons in Inorganic Metal Halides for Optoelectronic Applications
Guo, Q., Zhao, X., Song, B., Luo, J., & Tang, J. (2022) · Advanced Materials · doi:10.1002/adma.202201008 · Cited by 260
Infrared camera assessment of skin surface temperature—Effect of emissivity
Bernard, V., Staffa, E., Mornstein, V., & Bourek, A. (2013) · Physica Medica · doi:10.1016/j.ejmp.2012.09.003 · Cited by 177
Formenti, D., Ludwig, N., Gargano, M., Gondola, M., Dellerma, N., Caumo, A., & Alberti, G. (2013) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0718-x · Cited by 164
Assessment of Myofascial Trigger Points via Imaging: A Systematic Review
Mazza, D. F., Boutin, R. D., & Chaudhari, A. J. (2021) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0000000000001789 · Cited by 59
Khaksari, K., Nguyen, T., Hill, B. Y., Perrault, J., Gorti, V., Blick, E., Gonzalez Cano, T., Shadgan, B., Quang, T., Malpani, R., et al. (2021) · Journal of medical imaging · doi:10.1117/1.jmi.8.s1.010901 · Cited by 55
Weigert, M., Nitzsche, N., Kunert, F., Lösch, C., Baumgärtel, L., & Schulz, H. (2018) · International Journal of Kinesiology and Sports Science · doi:10.7575/aiac.ijkss.v.6n.1p.12 · Cited by 28
An Instrument for Accurate and Non-Invasive Screening of Skin Cancer Based on Multimodal Imaging
Diaz, S., Krohmer, T., Moreira, A., Godoy, S. E., & Figueroa, M. (2019) · IEEE Access · doi:10.1109/access.2019.2956898 · Cited by 27
Reference breast temperature: Proposal of an equation
Souza, G. A. G. R. D., Brioschi, M. L., Vargas, J. V. C., Morais, K. C. C., Dalmaso Neto, C., & Neves, E. B. (2015) · Einstein (São Paulo) · doi:10.1590/s1679-45082015ao3392 · Cited by 20
“Breast thermography is a functional examination proposed as an aid for investigation of new drugs,(27) chemotherapeutic agents,(28) progression monitoring of inflammatory diseases and screening of abnormalities,(29) and could be used in conjunction with clinical and anatomical examinations.”
MethodClothing for protection against heat and flames
Rossi, R. (2014) · Protective Clothing · doi:10.1533/9781782420408.1.70 · Cited by 17
An Infrared Thermography Model Enabling Remote Body Temperature Screening Up to 10 Meters
Chin, J. W., Long Wong, K., Chan, T. T., Suhartono, K., & So, R. H. Y. (2021) · 2021 IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw53098.2021.00429 · Cited by 16
Bridier, A., Shcherbakova, M., Kawaguchi, A., Poirier, N., Said, C., Noumeir, R., & Jouvet, P. (2023) · Frontiers in Pediatrics · doi:10.3389/fped.2023.1083962 · Cited by 6
Study on Human Temperature Measurement by Infrared Thermography
Švantner, M., Lang, V., Kohlschutter, T., Skála, J., Honner, M., Muzika, L., & Kosová, E. (2021) · The 16th International Workshop on Advanced Infrared Technology & Applications · doi:10.3390/engproc2021008004 · Cited by 5
Metadata
- Authors
- Lahiri, B. B., Bagavathiappan, S., Jayakumar, T., & Philip, J.
- Venue
- Infrared Physics & Technology
- Publisher
- Elsevier BV
- Published
- 2012-07
- Volume
- 55
- Issue
- 4
- Pages
- 221-235
- ISSN
- 1350-4495 (ISSN-L)
- OpenAlex
- W2077332544
- Cited by
- 1,333
- References
- 82
- FWCI
- 26.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.