The DOI matches its Crossref record; 18 of the 19 references it cites were found in a registry or an index.
Clinical Benefits of Remote Versus Transtelephonic Monitoring of Implanted Pacemakers
Open accessAbstract
Objectives The purpose of this study was to evaluate remote pacemaker interrogation for the earlier diagnosis of clinically actionable events compared with traditional transtelephonic monitoring and routine in-person evaluation.Background Pacemaker patient follow-up procedures have evolved from evaluating devices with little programmability and diagnostic information solely in person to transtelephonic rhythm strip recordings that allow monitoring of basic device function. More recently developed remote monitoring technology leverages expanded device capabilities, augmenting traditional transtelephonic monitoring to evaluate patients via full device interrogation.Methods The time to first diagnosis of a clinically actionable event was compared in patients who were followed by remote interrogation (Remote) and those who were followed per standard of care with office visits augmented by transtelephonic monitoring (Control). Patients were randomized 2:1. Remote arm patients transmitted pacemaker information at 3-month intervals. Control arm patients with a single-chamber pacemaker transmitted at 2-month intervals. Control arm patients with dual-chamber devices transmitted at 2-month intervals with an office visit at 6 months. All patients were seen in office at 12 months.Results The mean time to first diagnosis of clinically actionable events was earlier in the Remote arm (5.7 months) than in the Control arm (7.7 months). Three (2%) of the 190 events in the Control arm and 446 (66%) of 676 events in the Remote arm were identified remotely.Conclusions The strategic use of remote pacemaker interrogation follow-up detects actionable events that are potentially important more quickly and more frequently than transtelephonic rhythm strip recordings. The use of transtelephonic rhythm strips for pacemaker follow-up is of little value except for battery status determinations. (PREFER [Pacemaker Remote Follow-up Evaluation and Review]; NCT00294645).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In the Pacemaker Remote Follow-up Evaluation and Review (PREFER) trial, which randomly assigned 980 PM patients to follow-up with remote monitoring versus in-office visits plus transtelephonic monitoring, clinically actionable events such as atrial arrhythmias, increase in right ventricular pacing, lead function changes, and battery depletion, were detected earlier in the remote-monitoring arm.57”
From Managing with pacemakers and implantable cardioverter defibrillators (2013) · cites this paper as [57]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
A Class of Rank Test Procedures for Censored Survival Data
Harrington, D. P., & Fleming, T. R. (1982) · Biometrika · doi:10.1093/biomet/69.3.553 · Cited by 1,194
Epstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189741 · Cited by 366
Wilkoff, B. L., Auricchio, A., Brugada, J., Cowie, M., Ellenbogen, K. A., Gillis, A. M., Hayes, D. L., Howlett, J. G., Kautzner, J., Love, C. J., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.013 · Cited by 364
Self-citationLazarus, A. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00595.x · Cited by 227
Clinical Cardiac Pacing, Defibrillation, and Resynchronization Therapy
(2007) · Elsevier eBooks · doi:10.1016/b978-1-4160-2536-8.x5001-8 · Cited by 224
Remote Monitoring of Implantable Cardioverter Defibrillators: A Prospective Analysis
SCHOENFELD, M. H., COMPTON, S. J., MEAD, R. H., WEISS, D. N., SHERFESEE, L., ENGLUND, J., & MONGEON, L. R. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00524.x · Cited by 194
Self-citationOrlov, M. V., Ghali, J. K., Araghi‐Niknam, M., Sherfesee, L., Sahr, D. M., Hettrick, D. A., & for the Atrial High Rate Trial Investigators (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00682.x · Cited by 119
Sheard, L., Wright, N. M. J., Adams, C. E., Bound, N., Rushforth, B., Hart, R., & Tompkins, C. N. E. (2009) · Trials · doi:10.1186/1745-6215-10-53 · Cited by 117
Transtelephone pacemaker clinic
Furman, S., Parker, B., & Escher, D. J. W. (1971) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)42190-9 · Cited by 61
Research works printed but not linked: 1
- Chen, 2008, Design of the Pacemaker Remote Follow-up Evaluation and Review (PREFER) trial to assess the clinical value of the remote pacemaker interrogation in the management of pacemaker patients, Trials, 8, 1
Cited by
Sorted by citations
Epstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318276ce9b · Cited by 1,496
Tracy, C. M., Epstein, A. E., Darbar, D., Dimarco, J., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P., Link, M. S., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.007 · Cited by 748
Varma, N., Epstein, A. E., Irimpen, A., Schweikert, R., & Love, C. (2010) · Circulation · doi:10.1161/circulationaha.110.937409 · Cited by 594
Slotwiner, D. J., Varma, N., Akar, J. G., Annas, G. J., Beardsall, M., Fogel, R. I., Galizio, N. O., Glotzer, T. V., Leahy, R. A., Love, C. J., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.05.008 · Cited by 533
Self-citationThe CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) Trial
Crossley, G. H., Boyle, A., Vitense, H., Chang, Y., & Mead, R. H. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.012 · Cited by 526
Self-citationDaubert, J.-C., Saxon, L., Adamson, P. B., Auricchio, A., Berger, R. D., Beshai, J. F., Breithard, O., Brignole, M., Cleland, J., DeLurgio, D. B., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.07.025 · Cited by 467
Self-citationTracy, C. M., Epstein, A. E., Darbar, D., Dimarco, J., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P., Link, M. S., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.009 · Cited by 412
Tracy, C. M., Epstein, A. E., Darbar, D., Dimarco, J., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P., Link, M. S., et al. (2012) · Circulation · doi:10.1161/cir.0b013e3182618569 · Cited by 373
Landolina, M., Perego, G. B., Lunati, M., Curnis, A., Guenzati, G., Vicentini, A., Parati, G., Borghi, G., Zanaboni, P., Valsecchi, S., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.088971 · Cited by 344
Task Force Chairs, Daubert, J., Saxon, L. A., Adamson, P. B., Auricchio, A., Berger, R. D., Beshai, J. F., Breithard, O., Brignole, M., Cleland, J. G. F., et al. (2012) · EP Europace · doi:10.1093/europace/eus222 · Cited by 257
Self-citationGörenek, B., Bax, J. J., Boriani, G., Chen, S., Dagres, N., Glotzer, T. V., Healey, J. S., Israel, C. W., Kudaiberdieva, G., Levin, L., et al. (2017) · EP Europace · doi:10.1093/europace/eux163 · Cited by 249
Early performance of a miniaturized leadless cardiac pacemaker: the Micra Transcatheter Pacing Study
Ritter, P., Duray, G. Z., Steinwender, C., Soejima, K., Omar, R., Mont, L., Boersma, L. V. A., Knops, R. E., Chinitz, L. A., Zhang, S., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv214 · Cited by 232
Home Monitoring for Heart Failure Management
Bui, A. L., & Fonarow, G. C. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.09.044 · Cited by 204
Schwamm, L. H., Chumbler, N. R., Brown, E., Fonarow, G. C., Berube, D., Nyström, K. V., Suter, R. E., Zavala, M., Polsky, D. E., Radhakrishnan, K., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000475 · Cited by 212
Dubner, S., Auricchio, A., Steinberg, J. S., Vardas, P. E., Stone, P. H., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P. F., BREITHARDT, G. E., et al. (2012) · EP Europace · doi:10.1093/europace/eur303 · Cited by 178
Automatic Remote Monitoring of Implantable Cardioverter-Defibrillator Lead and Generator Performance
Varma, N., Michalski, J., Epstein, A. E., & Schweikert, R. A. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.110.951962 · Cited by 164
Tracy, C. M., Epstein, A. E., Darbar, D., Dimarco, J., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P., Link, M. S., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.08.021 · Cited by 163
Pandor, A., Thokala, P., Gomersall, T., Baalbaki, H., Stevens, J., Wang, J., Wong, R., Brennan, A., & Fitzgerald, P. (2013) · Health Technol Assess · doi:10.3310/hta17320 · Cited by 159
Ferrick, A. M., Raj, S. R., Deneke, T., Kojodjojo, P., López-Cabanillas, N., Abe, H., Bovéda, S., Chew, D. S., Choi, J., Dagres, N., et al. (2023) · Heart Rhythm · doi:10.1016/j.hrthm.2023.03.1525 · Cited by 122
Fernandez, F., Osca, J., Romero, R., Lozano, I. F., Larrazabal, J. M., Ferrer, J. M., Ortiz, R., Pombo, M., Tornés, F. J., & Kolbolandi, M. M. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehz067 · Cited by 117
Klersy, C., De Silvestri, A., Gabutti, G., Raisaro, A., Curti, M., Regoli, F., & Auricchio, A. (2011) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfq232 · Cited by 150
Boriani, G., Costa, A. D., Ricci, R. P., Quesada, A., Favale, S., Iacopino, S., Romeo, F., Risi, A., Stefano, L. M. D. S., Navarro, X., et al. (2013) · Journal of Medical Internet Research · doi:10.2196/jmir.2608 · Cited by 107
Telemedicine and cardiac implants: what is the benefit?
Varma, N., & Ricci, R. P. (2013) · European Heart Journal · doi:10.1093/eurheartj/ehs388 · Cited by 102
Remote monitoring of cardiovascular devices: a time and activity analysis
Cronin, E. M., Ching, E. A., Varma, N., Martin, D. O., Wilkoff, B. L., & Lindsay, B. D. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.08.002 · Cited by 95
Self-citationFerrick, A. M., Raj, S. R., Deneke, T., Kojodjojo, P., López-Cabanillas, N., Abe, H., Bovéda, S., Chew, D. S., Choi, J., Dagres, N., et al. (2023) · EP Europace · doi:10.1093/europace/euad123 · Cited by 89
Advances and Future Directions in Cardiac Pacemakers
Madhavan, M., Mulpuru, S. K., McLeod, C. J., Cha, Y., & Friedman, P. A. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.10.064 · Cited by 86
Simone, A. D., Leoni, L., Luzi, M., Amellone, C., Stabile, G., Rocca, V. L., Capucci, A., D’Onofrio, A., Ammendola, E., Accardi, F., et al. (2015) · EP Europace · doi:10.1093/europace/euu318 · Cited by 69
Cardiac resynchronization therapy: state of the art 2013
Yu, C.-M., & Hayes, D. L. (2013) · European Heart Journal · doi:10.1093/eurheartj/ehs454 · Cited by 68
Remote Management of Pacemaker Patients With Biennial In-Clinic Evaluation
Watanabe, E., Yamazaki, F., Goto, T., Asai, T., Yamamoto, T., Hirooka, K., Sato, T., Kasai, A., Ueda, M., Yamakawa, T., et al. (2020) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.119.007734 · Cited by 67
Tracy, C. M., Epstein, A. E., Darbar, D., Dimarco, J., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P., Link, M. S., et al. (2012) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2012.08.032 · Cited by 67
Svennberg, E., Caiani, E. G., Bruining, N., Desteghe, L., Han, J. K., Narayan, S. M., Rademakers, F. E., Sanders, P., & Duncker, D. (2023) · EP Europace · doi:10.1093/europace/euad176 · Cited by 66
JCS/JHRS 2021 Guideline Focused Update on Non-Pharmacotherapy of Cardiac Arrhythmias
Nogami, A., Kurita, T., KUSANO, K. F., Goya, M., Shoda, M., Tada, H., Naito, S., Yamane, T., Kimura, M., Shiga, T., et al. (2022) · Circulation Journal · doi:10.1253/circj.cj-21-0162 · Cited by 55
Yee, R., Verma, A., Beardsall, M., Fraser, J. A., Philippon, F., & Exner, D. V. (2013) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2012.11.036 · Cited by 54
Remote monitoring and telemedicine in heart failure: implementation and benefits
Imberti, J. F., Tosetti, A., Mei, D. A., Maisano, A., & Boriani, G. (2021) · Current Cardiology Reports · doi:10.1007/s11886-021-01487-2 · Cited by 53
Amara, W., Montagnier, C., Cheggour, S., Boursier, M., Gully, C., BARNAY, C., Georger, F., Deplagne, A., Fromentin, S., Młotek, M., et al. (2017) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13062 · Cited by 49
Home Telemonitoring in Patients With Chronic Heart Failure
Schmidt, S., Schuchert, A., Krieg, T., & Oeff, M. (2010) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.2010.0131 · Cited by 48
Home Monitoring of Cardiac Devices in the Era of COVID-19
Miller, J. C., Skoll, D., & Saxon, L. A. (2020) · Current Cardiology Reports · doi:10.1007/s11886-020-01431-w · Cited by 48
Dubner, S., Auricchio, A., Steinberg, J. S., Vardas, P., Stone, P., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P., Breithardt, G., et al. (2012) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2011.00484.x · Cited by 47
Varma, N., Pavri, B. B., Stambler, B. S., Michalski, J., & TRUST Investigators (2012) · EP Europace · doi:10.1093/europace/eus410 · Cited by 47
Follow-up of Patients With New Cardiovascular Implantable Electronic Devices
Al‐Khatib, S. M., Mi, X., Wilkoff, B. L., Qualls, L. G., Frazier‐Mills, C. G., Setoguchi, S., Hess, P. L., & Curtis, L. H. (2012) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.112.974337 · Cited by 47
Self-citationRemote monitoring of cardiac implantable electronic devices (CIED)
Zeitler, E. P., & Piccini, J. P. (2016) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2016.03.012 · Cited by 46
Remote Monitoring of Cardiac Implantable Electronic Devices
Cheung, C. C., & Deyell, M. W. (2018) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2018.01.003 · Cited by 45
Varma, N., Love, C. J., Michalski, J., & Epstein, A. E. (2021) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2021.01.008 · Cited by 44
JCS/JHRS 2021 guideline focused update on non‐pharmacotherapy of cardiac arrhythmias
Nogami, A., Kurita, T., KUSANO, K. F., Goya, M., Shoda, M., Tada, H., Naito, S., Yamane, T., Kimura, M., Shiga, T., et al. (2022) · Journal of Arrhythmia · doi:10.1002/joa3.12649 · Cited by 41
Performance of first pacemaker to use smart device app for remote monitoring
Tarakji, K. G., Zaidi, A. M., ZWEIBEL, S. L., Varma, N., Sears, S. F., Allred, J. D., Roberts, P. R., Shaik, N. A., Silverstein, J. R., Maher, A. R., et al. (2021) · Heart Rhythm O2 · doi:10.1016/j.hroo.2021.07.008 · Cited by 42
Compliance with Remote Monitoring of ICDS/CRTDS in a Real‐World Population
Rosenfeld, L. E., Patel, A. S., Ajmani, V. B., Holbrook, R., & BRAND, T. A. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12358 · Cited by 40
VOGTMANN, T., Stiller, S., Marek, A., Kespohl, S., Gomer, M., Kühlkamp, V., Zach, G., Löscher, S., & Baumann, G. (2012) · EP Europace · doi:10.1093/europace/eus252 · Cited by 39
(2018) · Europe PMC (PubMed Central) · Cited by 38
Managing with pacemakers and implantable cardioverter defibrillators
Lampert, R. (2013) · Circulation · doi:10.1161/circulationaha.113.001555 · Cited by 34
Maines, M., Palmisano, P., Greco, M. D., Melissano, D., Bonis, S. D., Baccillieri, S., Zanotto, G., D’Onofrio, A., Ricci, R. P., Ponti, R. D., et al. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10184086 · Cited by 33
Braunschweig, F., Anker, S. D., Proff, J., & Varma, N. (2019) · EP Europace · doi:10.1093/europace/euz011 · Cited by 31
Piotrowicz, R., Krzesiński, P., Balsam, P., Piotrowicz, E., Kempa, M., Lewicka, E., Główczyńska, R., Grabowski, M., Kołtowski, Ł., Peller, M., et al. (2021) · Kardiologia Polska · doi:10.33963/kp.15824 · Cited by 31
Bradyarrhythmias in the Elderly
Kumar, P., Kusumoto, F. M., & Goldschlager, N. (2012) · Clinics in Geriatric Medicine · doi:10.1016/j.cger.2012.08.004 · Cited by 31
Digital monitoring and care: Virtual medicine
Shinbane, J. S., & Saxon, L. A. (2016) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2016.05.007 · Cited by 31
Dechert, B. E., Serwer, G. A., Bradley, D. J., Dick, M., & LaPage, M. J. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.10.009 · Cited by 30
Self-citationRuvo, E. D., Sciarra, L., Martino, A. M., Rebecchi, M., Iulianella, R. V., Sebastiani, F., Fagagnini, A., Borrelli, A., Scarà, A., Grieco, D., et al. (2015) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-015-0067-4 · Cited by 30
Transparent sharing of digital health data: A call to action
Slotwiner, D. J., Tarakji, K. G., Al‐Khatib, S. M., PASSMAN, R. S., Saxon, L. A., Peters, N. S., McCall, D., Turakhia, M. P., Schaeffer, J., Mendenhall, G. S., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.04.042 · Cited by 29
Postmarket surveillance of medical devices: current capabilities and future opportunities
Blake, K. (2013) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-013-9778-6 · Cited by 29
Remote patient management using implantable devices
Movsowitz, C., & Mittal, S. (2011) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-011-9548-2 · Cited by 28
Remote monitoring of implantable devices: should we continue to ignore it?
Bertini, M., Marcantoni, L., Toselli, T., & Ferrari, R. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.09.033 · Cited by 28
Maines, M., Tomasi, G., Moggio, P., Peruzza, F., Catanzariti, D., Angheben, C., Simoncelli, M., Degiampietro, M., Piffer, L., Valsecchi, S., et al. (2020) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000001011 · Cited by 28
Remote monitoring of implantable cardiac devices
Ganeshan, R., Enriquez, A. D., & Freeman, J. V. (2017) · Current Opinion in Cardiology · doi:10.1097/hco.0000000000000471 · Cited by 27
Kelly, S., Campbell, D., Duhn, L., Giddens, K., Gillis, A. M., AbdelWahab, A. M., Nault, I., Raj, S. R., Lockwood, E. E., Basta, J., et al. (2020) · CJC Open · doi:10.1016/j.cjco.2020.11.010 · Cited by 27
Disease management: atrial fibrillation and Home Monitoring
Ricci, R. P. (2013) · EP Europace · doi:10.1093/europace/eut114 · Cited by 26
Current clinical evidence for remote patient management
Guédon-Moreau, L., Mabo, P., & Kacet, S. (2013) · EP Europace · doi:10.1093/europace/eut119 · Cited by 25
Douarin, Y.-M. L., Traversino, Y., Graciet, A., Josseran, A., Bili, A.-B., Blaise, L., Châtellier, G., Coulonjou, H., Delval, C., Detournay, B., et al. (2019) · Therapies · doi:10.1016/j.therap.2019.12.009 · Cited by 25
Recommendations on the utilization of telemedicine in cardiology
Working Group Rhythmology of the Austrian Cardiological Society, Gruska, M., Aigner, G., Altenberger, J., Burkart-Küttner, D., Fiedler, L., Gwechenberger, M., Lercher, P., Martinek, M., Nürnberg, M., et al. (2020) · Wiener klinische Wochenschrift · doi:10.1007/s00508-020-01762-2 · Cited by 24
Helms, T. M., Stockburger, M. A., Koehler, F., Leonhardt, V., Muller, A. M., Rybak, K., Sack, S., Schwab, J. O., Störk, S., Zippel‐Schultz, B., et al. (2019) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-018-0606-7 · Cited by 23
Varma, N. (2013) · EP Europace · doi:10.1093/europace/eut116 · Cited by 23
Perings, C. A., Bauer, W., Bondke, H., Mewis, C., James, M., Böcker, D., Broadhurst, P., Korte, T., Toft, E., Hintringer, F., et al. (2011) · EP Europace · doi:10.1093/europace/euq447 · Cited by 22
Li, Y., Pastori, D., Miyazawa, K., Shahid, F., & Lip, G. Y. H. (2021) · Journal of the American Heart Association · doi:10.1161/jaha.120.017519 · Cited by 22
ROSENTHAL, L. S., MESTER, S., Rakovec, P., Peñaranda, J. B., Sherman, J. R., Sheldon, T., Zeng, C., Wang, P. J., & for the CAPTURE Trial Investigators (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02809.x · Cited by 22
Ferrick, A. M., Raj, S. R., Deneke, T., Kojodjojo, P., López-Cabanillas, N., Abe, H., Bovéda, S., Chew, D. S., Choi, J., Dagres, N., et al. (2023) · Journal of Arrhythmia · doi:10.1002/joa3.12851 · Cited by 21
Ruvo, E. D., Gargaro, A., Sciarra, L., Luca, L. D., Zuccaro, L. M., Stirpe, F., Rebecchi, M., Sette, A., Lioy, E., & Calò, L. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02932.x · Cited by 20
Mascioli, G., Curnis, A., Landolina, M., Klersy, C., Gelmini, G., Ruffa, F., on behalf of ATHENS Investigators, Mascioli, G., Lucca, E., Bakhtadze, N., et al. (2011) · EP Europace · doi:10.1093/europace/eur233 · Cited by 20
Cardiac rhythm management devices
Stevenson, I., & Voskoboinik, A. (2018) · Australian Journal of General Practice · doi:10.31128/ajgp-12-17-4439 · Cited by 19
Emerging Role of Digital Technology and Remote Monitoring in the Care of Cardiac Patients
Banchs, J. E., & Scher, D. M. (2015) · Medical Clinics of North America · doi:10.1016/j.mcna.2015.02.013 · Cited by 19
Device Features for Managing Patients with Heart Failure
Varma, N., & Wilkoff, B. L. (2011) · Heart Failure Clinics · doi:10.1016/j.hfc.2010.12.005 · Cited by 18
Self-citationMaines, M., Tomasi, G., Moggio, P., Poian, L., Peruzza, F., Catanzariti, D., Angheben, C., Cont, N., Valsecchi, S., & Greco, M. D. (2021) · International Journal of Cardiology · doi:10.1016/j.ijcard.2021.04.043 · Cited by 17
Cronin, E. M., & Varma, N. (2012) · Expert Review of Medical Devices · doi:10.1586/erd.12.18 · Cited by 17
Ethics and the cardiac pacemaker: more than just end-of-life issues
Hutchison, K., & Sparrow, R. (2017) · EP Europace · doi:10.1093/europace/eux019 · Cited by 17
Pron, G. E., Ieraci, L., & Kaulback, K. (2012) · Europe PMC (PubMed Central) · Cited by 17
HRS Policy Statement: Clinical Cardiac Electrophysiology Fellowship Curriculum: Update 2011
Link, M. S., Exner, D. V., Anderson, M. E., Ackerman, M., Al‐Ahmad, A., Knight, B. P., Markowitz, S. M., Kaufman, E. S., Haines, D. E., Asirvatham, S. J., et al. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.06.008 · Cited by 16
Clinical recognition of pacemaker battery depletion and automatic reprogramming
Sinha, S. K., Chrispin, J., Barth, A. S., Rickard, J., SPRAGG, D. D., Berger, R. D., Calkins, H. G., Tomaselli, G. F., & Marine, J. E. (2017) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13135 · Cited by 16
Holtzman, J. N., Wadhera, R. K., Choi, E. H., Zhao, T., Secemsky, E. A., Fraiche, A. M., Shen, C., & Kramer, D. B. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2020.05.044 · Cited by 16
Lim, P., Lee, A., Chua, K., Lim, E., Chong, D. W. S., Tan, B., Ho, K., Teo, W. S., & Ching, C. (2016) · Singapore Medical Journal · doi:10.11622/smedj.2016120 · Cited by 16
Jamil, H. A., Mohammed, S., Gierula, J., Paton, M. F., Lowry, J. E., Cubbon, R. M., Kearney, M. T., & Witte, K. K. (2018) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2018.10.040 · Cited by 15
Gramegna, L., Tomasi, C., Gasparini, G. M., Scaboro, G., Zanon, F., Boaretto, G., Tomei, R., & Tomasi, L. (2011) · EP Europace · doi:10.1093/europace/eur334 · Cited by 14
López-Villegas, A., Catalán-Matamoros, D., Saborido, C. M., Villegas-Tripiana, I., & Robles‐Musso, E. (2015) · Revista Española de Cardiología · doi:10.1016/j.recesp.2015.06.021 · Cited by 14
Technology-Assisted Congestive Heart Failure Care
Iyngkaran, P., Toukhsati, S. R., Biddagardi, N., Zimmet, H., Atherton, J. J., & Hare, D. L. (2015) · Current Heart Failure Reports · doi:10.1007/s11897-014-0251-3 · Cited by 14
The Use of App-based Follow-up of Cardiac Implantable Electronic Devices
Roberts, P. R., & ElRefai, M. (2020) · Cardiac failure review · doi:10.15420/cfr.2019.13 · Cited by 14
Zoppo, F., Facchin, D., Molon, G., Zanotto, G., Catanzariti, D., Rossillo, A., Baccillieri, S., MENARD, C., COMISSO, J., Gentili, A., et al. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12474 · Cited by 14
Pacemaker Remote Monitoring in the Pediatric Population: Is It A Real Solution?
Leoni, L., Padalino, M. A., Biffanti, R., Ferretto, S., Vettor, G., Corrado, D., Stellin, G., Milanesi, O., & Iliceto, S. (2015) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12600 · Cited by 14
Incidence and predictors of pacemaker reprogramming: potential consequences for remote follow-up
Udo, E. O., van Hemel, N. M., Zuithoff, N. P. A., Barrett, M. J., RUITER, J. H., Doevendans, P. A., & Moons, K. G. M. (2013) · EP Europace · doi:10.1093/europace/eut002 · Cited by 14
Giannola, G., Torcivia, R., Farulla, R. A., & Cipolla, T. (2018) · JMIR Cardio · doi:10.2196/cardio.9815 · Cited by 13
In‐home controls of pacemakers in debilitated elderly patients
Folino, A. F., Breda, R., Calzavara, P., Migliore, F., Iliceto, S., & Buja, G. (2011) · Geriatrics and gerontology international/Geriatrics & gerontology international · doi:10.1111/j.1447-0594.2011.00723.x · Cited by 13
Facchin, D., Baccillieri, S., GASPARINI, G., Zoppo, F., Allocca, G., Brieda, M., Verlato, R., & Proclemer, A. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.06.162 · Cited by 13
Mittal, S., Movsowitz, C., & Varma, N. (2014) · Cardiology Clinics · doi:10.1016/j.ccl.2014.01.001 · Cited by 12
Selby, P. J., Banks, R. E., Gregory, W. M., Hewison, J., Rosenberg, W. M., Altman, D. G., Deeks, J. J., McCabe, C. J., Parkes, J., Sturgeon, C. M., et al. (2018) · Programme Grants for Applied Research · doi:10.3310/pgfar06030 · Cited by 12
Home Monitoring for Cardiovascular Implantable Electronic Devices
Leahy, R. A., & Davenport, E. E. (2015) · AACN Advanced Critical Care · doi:10.1097/nci.0000000000000110 · Cited by 11
Metadata
- Authors
- Crossley, G. H., Chen, J., Choucair, W., Cohen, T. J., Gohn, D. C., Johnson, W. B., Kennedy, E. E., Mongeon, L. R., Serwer, G. A., Qiao, H., & Wilkoff, B. L.
- Affiliations
- University of Tennessee at Knoxville (US)
- Washington University in St. Louis (US)
- Winthrop-University Hospital (US)
- Arkansas Heart Hospital (US)
- Medtronic (United States) (US)
- University of Michigan (US)
- Cleveland Clinic (US)
- Corresponding author
- Crossley, George H.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2009-11
- Volume
- 54
- Issue
- 22
- Pages
- 2012-2019
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W1989653793
- Cited by
- 202
- References
- 19
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 2 · 2023: 11 · 2022: 5 · 2021: 13 · 2020: 12 · 2019: 9 · 2018: 11 · 2017: 11 · 2016: 14 · 2015: 18 · 2014: 11 · 2013: 27 · 2012: 27
- FWCI
- 11.21
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of the American College of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Medtronic
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Telemedicine and Telehealth Implementation
- Keywords
- transtelephonic monitoring, implantable pacemaker, pacemaker follow-up, time to diagnosis, remote monitoring, device interrogation, battery status, single-chamber pacemaker, dual-chamber pacemaker
- MeSH terms
- Aged, Aged, 80 and over, Arrhythmias, Cardiac, Coronary Artery Disease, Diabetic Angiopathies, Female, Heart Failure, Humans, Male, Middle Aged, Monitoring, Physiologic, Office Visits, Pacemaker, Artificial, Prospective Studies, Telemetry, Telephone, Time Factors, Comorbidity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review