The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Home Monitoring for Heart Failure Management
Open accessAbstract
With a prevalence of 5.8 million in the United States alone, heart failure (HF) is a common syndrome associated with substantial morbidity, mortality, and health-care expenditures. Close to 1 million HF hospitalizations occur annually in the United States, with the majority of these resulting from worsening congestion in patients previously diagnosed with HF. An estimated 37.2 billion dollars is spent each year on HF in the United States. These statistics emphasize the need to develop and implement more effective strategies to assess, monitor, and treat HF. It has also become increasingly apparent that interventions geared towards identifying and monitoring sub-clinical congestion would be of value in the home management of chronic HF. Earlier identification and treatment of congestion together with improved care coordination, management of comorbid conditions, and enhanced patient self-management may help to prevent hospitalizations in patients with chronic HF. Such home monitoring extends from the promotion of self-care and home visitations, to telemedicine and remote monitoring of external or implantable devices. This paper will discuss the challenges in monitoring patients with HF, review clinical trials testing different monitoring strategies in HF, and highlight ongoing investigations into the optimal approaches to home monitoring for HF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Disease and Stroke Statistics—2023 Update: A Report From the American Heart Association
Tsao, C. W., Aday, A. W., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Beaton, A. Z., Boehme, A. K., Buxton, A. E., et al. (2023) · Circulation · doi:10.1161/cir.0000000000001123 · Cited by 8,300
WRITING COMMITTEE MEMBERS, Hunt, S. A., Abraham, W. T., Chin, M. H., Feldman, A. M., Francis, G. S., Ganiats, T. G., Jessup, M., Konstam, M. A., Mancini, D. M., et al. (2005) · Circulation · doi:10.1161/circulationaha.105.167586 · Cited by 2,251
Telemonitoring in patients with heart failure
Chaudhry, S. I., Mattera, J. A., Curtis, J. P., Spertus, J. A., Herrin, J., Lin, Z., Phillips, C. O., Hodshon, B. V., Cooper, L. S., & Krumholz, H. M. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1010029 · Cited by 1,232
Health Literacy Among Medicare Enrollees in a Managed Care Organization
Gazmararian, J. A. (1999) · JAMA · doi:10.1001/jama.281.6.545 · Cited by 876
Koehler, F., Winkler, S., Schieber, M., Sechtem, U., Stangl, K., Böhm, M., Boll, H., Baumann, G., Honold, M., Koehler, K., et al. (2011) · Circulation · doi:10.1161/circulationaha.111.018473 · Cited by 716
Structured telephone support or telemonitoring programmes for patients with chronic heart failure
Inglis, S. C., Clark, R. A., McAlister, F. A., Ball, J., Lewinter, C., Cullington, D., Stewart, S., & Cleland, J. G. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007228.pub2 · Cited by 614
The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) Trial
Crossley, G. H., Boyle, A., Vitense, H., Chang, Y., & Mead, R. H. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.012 · Cited by 526
Wilkoff, B. L., Auricchio, A., Brugada, J., Cowie, M., Ellenbogen, K. A., Gillis, A. M., Hayes, D. L., Howlett, J. G., Kautzner, J., Love, C. J., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.013 · Cited by 364
Clinical Benefits of Remote Versus Transtelephonic Monitoring of Implanted Pacemakers
Crossley, G. H., Chen, J., Choucair, W., Cohen, T. J., Gohn, D. C., Johnson, W. B., Kennedy, E. E., Mongeon, L. R., Serwer, G. A., Qiao, H., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.10.001 · Cited by 202
Cited by
Power Approaches for Implantable Medical Devices
Amar, A., Kouki, A., & Cao, H. (2015) · Sensors · doi:10.3390/s151128889 · Cited by 432
Diretriz Brasileira de Insuficiência Cardíaca Crônica e Aguda
Rohde, L. E. P., Montera, M. W., Bocchi, E. A., Clausell, N. O., Albuquerque, D. C. D., Rassi, S., Colafranceschi, A. S., Freitas Junior, A. F. D., Ferraz, A. S., Biolo, A., et al. (2018) · Arquivos Brasileiros de Cardiologia · doi:10.5935/abc.20180190 · Cited by 377
Philip, N. Y., Rodrigues, J. J. P. C., Wang, H., Fong, S. J., & Chen, J. (2021) · IEEE Journal on Selected Areas in Communications · doi:10.1109/jsac.2020.3042421 · Cited by 319
Vincent, C., & Amalberti, R. (2016) · doi:10.1007/978-3-319-25559-0 · Cited by 278
Inan, O. T., Baran Pouyan, M., Javaid, A. Q., Dowling, S., Etemadi, M., Dorier, A., Heller, J. A., Bicen, A. O., Roy, S., De Marco, T., et al. (2018) · Circulation: Heart Failure · doi:10.1161/circheartfailure.117.004313 · Cited by 207
Metadata
- Authors
- Bui, A. L., & Fonarow, G. C.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2012-01
- Volume
- 59
- Issue
- 2
- Pages
- 97-104
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2079640164
- Cited by
- 203
- References
- 9
- FWCI
- 12.28
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Home Monitoring for Heart Failure Management. https://app.cochat.ai/papers/10.1016/j.jacc.2011.09.044
- The paper
- Bui, A. L., & Fonarow, G. C. (2012). Home Monitoring for Heart Failure Management. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2011.09.044
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.