Cited by 202Cardiac pacing and defibrillation studiesECG Monitoring and AnalysisTelemedicine and Telehealth Implementation

Clinical Benefits of Remote Versus Transtelephonic Monitoring of Implanted Pacemakers

Open access
Crossley, George H., Chen, Jane, Choucair, Wassim, Cohen, Todd J., Gohn, Douglas C., Johnson, W. Ben, Kennedy, Eleanor E., Mongeon, Luc R. +3 more·2009·Journal of the American College of Cardiology

Abstract

Objectives The purpose of this study was to evaluate remote pacemaker interrogation for the earlier diagnosis of clinically actionable events compared with traditional transtelephonic monitoring and routine in-person evaluation.Background Pacemaker patient follow-up procedures have evolved from evaluating devices with little programmability and diagnostic information solely in person to transtelephonic rhythm strip recordings that allow monitoring of basic device function. More recently developed remote monitoring technology leverages expanded device capabilities, augmenting traditional transtelephonic monitoring to evaluate patients via full device interrogation.Methods The time to first diagnosis of a clinically actionable event was compared in patients who were followed by remote interrogation (Remote) and those who were followed per standard of care with office visits augmented by transtelephonic monitoring (Control). Patients were randomized 2:1. Remote arm patients transmitted pacemaker information at 3-month intervals. Control arm patients with a single-chamber pacemaker transmitted at 2-month intervals. Control arm patients with dual-chamber devices transmitted at 2-month intervals with an office visit at 6 months. All patients were seen in office at 12 months.Results The mean time to first diagnosis of clinically actionable events was earlier in the Remote arm (5.7 months) than in the Control arm (7.7 months). Three (2%) of the 190 events in the Control arm and 446 (66%) of 676 events in the Remote arm were identified remotely.Conclusions The strategic use of remote pacemaker interrogation follow-up detects actionable events that are potentially important more quickly and more frequently than transtelephonic rhythm strip recordings. The use of transtelephonic rhythm strips for pacemaker follow-up is of little value except for battery status determinations. (PREFER [Pacemaker Remote Follow-up Evaluation and Review]; NCT00294645).

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2009.10.001

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In the PREFER trial, clinically actionable events such as atrial arrhythmias, increase in right ventricular pacing, lead function changes, and battery depletion were detected earlier in the remote-monitoring arm.

    “In the Pacemaker Remote Follow-up Evaluation and Review (PREFER) trial, which randomly assigned 980 PM patients to follow-up with remote monitoring versus in-office visits plus transtelephonic monitoring, clinically actionable events such as atrial arrhythmias, increase in right ventricular pacing, lead function changes, and battery depletion, were detected earlier in the remote-monitoring arm.57”

    From Managing with pacemakers and implantable cardioverter defibrillators (2013) · cites this paper as [57]

    The Abstract and participant-flow/results section report that clinically actionable events were detected earlier in the remote arm (mean 5.7 versus 7.7 months). However, the Clinically Actionable Events table says lead-function changes and battery-depletion indicators were not used in the analysis because events were too few to establish earlier detection for those categories. The participant-flow section also says 980 patients were screened, but only 897 were randomized. (LLM, conf=0.91)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 19 references couldn’t be matched to a known paper.

Research works printed but not linked: 1

  1. [1]1. Furman S, Parker B, Escher DJ. Trans-telephone pacemaker clinic. J Thorac Cardiovasc Surg 1971;61:827-34.

Cited by

Sorted by citations

Authors
Crossley, G. H., Chen, J., Choucair, W., Cohen, T. J., Gohn, D. C., Johnson, W. B., Kennedy, E. E., Mongeon, L. R., Serwer, G. A., Qiao, H., & Wilkoff, B. L.
Affiliations
  • University of Tennessee at Knoxville (US)
  • Washington University in St. Louis (US)
  • Winthrop-University Hospital (US)
  • Arkansas Heart Hospital (US)
  • Medtronic (United States) (US)
  • University of Michigan (US)
  • Cleveland Clinic (US)
Corresponding author
Crossley, George H.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2009-11
Volume
54
Issue
22
Pages
2012-2019
ISSN
0735-1097 (ISSN-L)
OpenAlex
W1989653793
Cited by
202
References
19
Citations by year
2026: 3 · 2025: 3 · 2024: 2 · 2023: 11 · 2022: 5 · 2021: 13 · 2020: 12 · 2019: 9 · 2018: 11 · 2017: 11 · 2016: 14 · 2015: 18 · 2014: 11 · 2013: 27 · 2012: 27
FWCI
11.21
Type
journal article
Language
en
Open access
Locations
  • Journal of the American College of Cardiology (publishedVersion)
  • PubMed (publishedVersion)
Funders
Medtronic
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Telemedicine and Telehealth Implementation
Keywords
transtelephonic monitoring, implantable pacemaker, pacemaker follow-up, time to diagnosis, remote monitoring, device interrogation, battery status, single-chamber pacemaker, dual-chamber pacemaker
MeSH terms
Aged, Aged, 80 and over, Arrhythmias, Cardiac, Coronary Artery Disease, Diabetic Angiopathies, Female, Heart Failure, Humans, Male, Middle Aged, Monitoring, Physiologic, Office Visits, Pacemaker, Artificial, Prospective Studies, Telemetry, Telephone, Time Factors, Comorbidity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review