The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Undetectable High-Sensitivity Cardiac Troponin T Level in the Emergency Department and Risk of Myocardial Infarction
Open accessAbstract
OBJECTIVES: This study sought to evaluate if an undetectable (<5 ng/l) high-sensitivity cardiac troponin T (hs-cTnT) level and an electrocardiogram (ECG) without signs of ischemia can rule out myocardial infarction (MI) in the emergency department (ED). BACKGROUND: Chest pain is a common symptom often associated with benign conditions, but may be a sign of MI. Because there is no rapid way to rule out MI, many patients are admitted to the hospital. METHODS: All patients who sought medical attention for chest pain and had at least 1 hs-cTnT analyzed during 2 years at the Karolinska University Hospital, Stockholm, Sweden, were included. We calculated the negative predictive values of an undetectable hs-cTnT and ECG without ischemia for MI and death within 30 days. RESULTS: We included 14,636 patients, of whom 8,907 (61%) had an initial hs-cTnT of <5 ng/l; 21% had 5 to 14 ng/l, and 18% had >14 ng/l. During 30-day follow-up, 39 (0.44%) patients with undetectable hs-cTnT had a MI, of whom 15 (0.17%) had no ischemic ECG changes. The negative predictive value for MI within 30 days in patients with undetectable hs-cTnT and no ischemic ECG changes was 99.8% (95% confidence interval [CI]: 99.7 to 99.9). The negative predictive value for death was 100% (95% CI: 99.9 to 100). CONCLUSIONS: All patients with chest pain who have an initial hs-cTnT level of <5 ng/l and no signs of ischemia on an ECG have a minimal risk of MI or death within 30 days, and can be safely discharged directly from the ED.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
External review and validation of the Swedish national inpatient register
Ludvigsson, J. F., Andersson, E., Ekbom, A., Feychting, M., Kim, J.-L., Reuterwall, C., Heurgren, M., & Olausson, P. O. (2011) · BMC Public Health · doi:10.1186/1471-2458-11-450 · Cited by 5,055
Third Universal Definition of Myocardial Infarction
Thygesen, K., Alpert, J. S., Jaffe, A. S., Simoons, M. L., Chaitman, B. R., White, H. D., Thygesen, K., Alpert, J. S., White, H. D., Jaffe, A. S., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.08.001 · Cited by 2,621
National Hospital Ambulatory Medical Care Survey: 1994 emergency department summary.
Stussman, B. J. (1996) · PubMed · Cited by 2,232
Wettermark, B., Hammar, N., MichaelFored, C., Leimanis, A., Otterblad Olausson, P., Bergman, U., Persson, I., Sundström, A., Westerholm, B., & Rosén, M. (2007) · Pharmacoepidemiology and Drug Safety · doi:10.1002/pds.1294 · Cited by 1,887
Missed Diagnoses of Acute Cardiac Ischemia in the Emergency Department
Pope, J. H., Aufderheide, T. P., Ruthazer, R., Woolard, R. H., Feldman, J. A., Beshansky, J. R., Griffith, J. L., & Selker, H. P. (2000) · New England Journal of Medicine · doi:10.1056/nejm200004203421603 · Cited by 1,794
Early Diagnosis of Myocardial Infarction with Sensitive Cardiac Troponin Assays
Reichlin, T., Hochholzer, W., Bassetti, S., Steuer, S., Stelzig, C., Hartwiger, S., Biedert, S., Schaub, N., Buerge, C., Potocki, M., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0900428 · Cited by 1,687
National Hospital Ambulatory Medical Care Survey: 2007 Emergency Department Summary: (587172010-001)
Niska, R., Bhuiya, F., & Xu, J. (2010) · PsycEXTRA Dataset · doi:10.1037/e587172010-001 · Cited by 1,566
Sensitive Troponin I Assay in Early Diagnosis of Acute Myocardial Infarction
Keller, T., Zeller, T., Peetz, D., Tzikas, S., Roth, A., Czyz, E., Bickel, C., Baldus, S., Warnholtz, A., Fröhlich, M., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0903515 · Cited by 1,150
Analytical Validation of a High-Sensitivity Cardiac Troponin T Assay
Giannitsis, E., Kurz, K., Hallermayer, K., Jarausch, J., Jaffe, A. S., & Katus, H. A. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.132654 · Cited by 1,084
Hamm, C. W., Goldmann, B. U., Heeschen, C., Kreymann, G., Berger, J., & Meinertz, T. (1997) · New England Journal of Medicine · doi:10.1056/nejm199712043372302 · Cited by 1,039
Reichlin, T., Schindler, C., Drexler, B., Twerenbold, R., Reiter, M., Zellweger, C., Moehring, B., Ziller, R., Hoeller, R., Rubini Gimenez, M., et al. (2012) · Archives of Internal Medicine · doi:10.1001/archinternmed.2012.3698 · Cited by 551
The health care burden of acute chest pain: Figure 1
Goodacre, S., Cross, E., Arnold, J., Angelini, K., Capewell, S., & Nicholl, J. (2005) · Heart · doi:10.1136/hrt.2003.027599 · Cited by 486
Body, R., Carley, S., McDowell, G., Jaffe, A. S., France, M., Cruickshank, K., Wibberley, C., Nuttall, M., & Mackway-Jones, K. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.06.026 · Cited by 367
Than, M., Cullen, L., Reid, C. M., Lim, S. H., Aldous, S., Ardagh, M. W., Peacock, W. F., Parsonage, W. A., Ho, H. F., Ko, H. F., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60310-3 · Cited by 341
Pollack, C. V., Sites, F. D., Shofer, F. S., Sease, K. L., & Hollander, J. E. (2006) · Academic Emergency Medicine · doi:10.1197/j.aem.2005.06.031 · Cited by 255
Rubini Giménez, M., Hoeller, R., Reichlin, T., Zellweger, C., Twerenbold, R., Reiter, M., Moehring, B., Wildi, K., Mosimann, T., Mueller, M., et al. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.06.049 · Cited by 193
Park, D.-W., Kim, Y. H., Yun, S., Ahn, J., Lee, J., Kim, W., Kang, S., Lee, S.-W., Lee, C. W., Park, S.-W., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht048 · Cited by 164
The new Vancouver Chest Pain Rule using troponin as the only biomarker: an external validation study
Cullen, L., Greenslade, J. H., Than, M. P., Brown, A. F., Hammett, C. J. K., Lamanna, A., Flaws, D., Chu, K., Fowles, L., & Parsonage, W. A. (2013) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2013.10.021 · Cited by 54
Cited by
Roffi, M., Patrono, C., Collet, J.-P., Mueller, C., Valgimigli, M., Andreotti, F., Bax, J. J., Borger, M. A., Brotons, C., Chew, D. P., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv320 · Cited by 8,261
Gulati, M., Levy, P. D., Mukherjee, D., Amsterdam, E., Bhatt, D. L., Birtcher, K. K., Blankstein, R., Boyd, J., Bullock-Palmer, R. P., Conejo, T., et al. (2021) · Circulation · doi:10.1161/cir.0000000000001029 · Cited by 1,611
2021 AHA/ACC/ASE/CHEST/SAEM/SCCT/SCMR Guideline for the Evaluation and Diagnosis of Chest Pain
Gulati, M., Levy, P. D., Mukherjee, D., Amsterdam, E., Bhatt, D. L., Birtcher, K. K., Blankstein, R., Boyd, J., Bullock-Palmer, R. P., Conejo, T., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.07.053 · Cited by 824
JCS 2018 Guideline on Diagnosis and Treatment of Acute Coronary Syndrome
Kimura, K., Kimura, T., Ishihara, M., Nakagawa, Y., Nakao, K., Miyauchi, K., Sakamoto, T., Tsujita, K., Hagiwara, N., Miyazaki, S., et al. (2019) · Circulation Journal · doi:10.1253/circj.cj-19-0133 · Cited by 565
Shah, A. S. V., Anand, A., Sandoval, Y., Lee, K. K., Smith, S. W., Adamson, P. D., Chapman, A. R., Langdon, T., Sandeman, D., Vaswani, A., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)00391-8 · Cited by 510
Metadata
- Authors
- Bandstein, N., Ljung, R., Johansson, M., & Holzmann, M. J.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2014-06
- Volume
- 63
- Issue
- 23
- Pages
- 2569-2578
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2014012527
- Cited by
- 268
- References
- 18
- FWCI
- 32.22
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.