Dual-Chamber Pacing With Closed Loop Stimulation in Recurrent Reflex Vasovagal Syncope
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Pacing in vasovagal syncope remains controversial. OBJECTIVES: The authors evaluated dual-chamber pacing with closed loop stimulation (DDD-CLS) in patients with cardioinhibitory vasovagal syncope. METHODS: This randomized, double-blind, controlled study included Canadian and Spanish patients age ≥40 years, with high burden syncope (≥5 episodes, ≥2 episodes in the past year), and a cardioinhibitory head-up tilt test (bradycardia <40 beats/min for 10 s or asystole >3 s). Patients were randomized to either DDD-CLS pacing for 12 months followed by sham DDI mode pacing at 30 pulses/min for 12 months (group A), or sham DDI mode for 12 months followed by DDD-CLS pacing for 12 months (group B). Patients in both arms crossed-over after 12 months of follow-up or when a maximum of 3 syncopal episodes occurred within 1 month. RESULTS: A total of 46 patients completed the protocol; 22 were men (47.8%), and mean age was 56.30 ± 10.63 years. The mean number of previous syncopal episodes was 12 (range 9 to 20). The proportion of patients with ≥50% reduction in the number of syncopal episodes was 72% (95% confidence interval [CI]: 47% to 90%) with DDD-CLS compared with 28% (95% CI: 9.7% to 53.5%) with sham DDI mode (p = 0.017). A total of 4 patients (8.7%) had events during DDD-CLS and 21 (45.7%) during sham DDI (hazard ratio: 6.7; 95% CI: 2.3 to 19.8). Kaplan-Meier curve was significantly different between groups in time to first syncope: 29.2 months (95% CI: 15.3 to 29.2 months) versus 9.3 months (95% CI: 6.21 months, NA; p < 0.016); odds ratio: 0.11 (95% CI: 0.03 to 0.37; p < 0.0001). CONCLUSIONS: DDD-CLS pacing significantly reduced syncope burden and time to first recurrence by 7-fold, prolonging time to first syncope recurrence in patients age ≥40 years with head-up tilt test-induced vasovagal syncope compared with sham pacing. (Closed Loop Stimulation for Neuromediated Syncope [SPAIN Study]; NCT01621464).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Connolly, S. J., Sheldon, R., Thorpe, K. E., Roberts, R. S., Ellenbogen, K. A., Wilkoff, B. L., Morillo, C., Gent, M., & for the VPS II Investigators (2003) · JAMA · doi:10.1001/jama.289.17.2224 · Cited by 500 · cited 3×
“These findings are consistent with previously published data, suggesting that pacing may prevent syncope, but not pre-syncope (4).”
BackgroundMethodResultSelf-citationBrignole, M. (2000) · Europace · doi:10.1053/eupc.1999.0064 · Cited by 451 · cited 1×
“For this trial, we only included patients with a cardioinhibitory response: bradycardia <40 beats/min during >10 s or asystole >3 s, as per the VASIS (Vasovagal Syncope International Study) classification (14).”
MethodBrignole, M., Menozzi, C., Moya, A., Andresen, D., Blanc, J. J., Krahn, A. D., Wieling, W., Beiras, X., Deharo, J. C., Russo, V., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.082313 · Cited by 437 · cited 2×
“ISSUE-3, which initially screened 511 patients who had an implantable cardiac monitor inserted but randomized only 79 patients, compared pacing versus no pacing in an older population with either syncope with documented asystole >3 s or an asymptomatic asystole >6 s (6).”
BackgroundMethodSutton, R., Brignole, M., Menozzi, C., Raviele, A., Alboni, P., Giani, P., & Moya, A. (2000) · Circulation · doi:10.1161/01.cir.102.3.294 · Cited by 407
RAVIELE, A., GIADA, F., MENOZZI, C., SPECA, G., ORAZI, S., GASPARINI, G., SUTTON, R., & BRIGNOLE, M. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.031 · Cited by 323 · cited 2×
“Our trial did not directly compare DDD-CLS pacing mode with other dualchamber pacing modes (DDI with hysteresis, DDD with rate drop response, and so on) that have had limited success in preventing recurrence of VVS (4,5).”
BackgroundMethodBartoletti, A. (2000) · Europace · doi:10.1053/eupc.2000.0125 · Cited by 315 · cited 1×
“HUT was performed using 2 previously reported protocols (12,13).”
MethodAmmirati, F., Colivicchi, F., & Santini, M. (2001) · Circulation · doi:10.1161/hc2601.091708 · Cited by 299
Shen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.03.002 · Cited by 155
The expectation effect and cardiac pacing for refractory vasovagal syncope
Sud, S., Massel, D., Klein, G. J., Leong-Sit, P., Yee, R., Skanes, A. C., Gula, L. J., & Krahn, A. D. (2007) · The American Journal of Medicine · doi:10.1016/j.amjmed.2006.05.046 · Cited by 151 · cited 1×
“Time to first recurrence of syncope correlates well with frequency of syncope, which may be more clinically relevant from the patient’s perspective and for health care resource utilization (17).”
BackgroundBrignole, M., Donateo, P., Tomaino, M., Massa, R., Iori, M., Beiras, X., Moya, A., Kus, T., Deharo, J. C., Giuli, S., et al. (2014) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.113.001103 · Cited by 127 · cited 1×
“Our findings contrast with a post hoc analysis of ISSUE 3, in which patients with documented asystolic neurally mediated reflex syncope documented by an implantable cardiac monitor and a HUT with a cardioinhibitory response who received a pacemaker did not have a significant reduction in syncope recurrence (15).”
Result
Cited by
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
Self-citation2018 ESC Guidelines for the diagnosis and management of syncope
Brignole, M., Moya, A., de Lange, F. J., Deharo, J.-C., Elliott, P. M., Fanciulli, A., Fedorowski, A., Furlan, R., Kenny, R. A., Martín, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy037 · Cited by 1,951
Self-citation2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · EP Europace · doi:10.1093/europace/euab232 · Cited by 914
2018 ESC Guidelines for the diagnosis and management of syncope
Brignole, M., Moya, A., De Lange, F. J., Deharo, J.-C., Elliott, P. M., Fanciulli, A., Fedorowski, A., Furlan, R., Kenny, R. A., Martiın, A., et al. (2018) · Kardiologia Polska · doi:10.5603/kp.2018.0161 · Cited by 476
ACC/AHA/HRS Versus ESC Guidelines for the Diagnosis and Management of Syncope
Goldberger, Z. D., Petek, B. J., Brignole, M., Shen, W.-K., Sheldon, R. S., Solbiati, M., Deharo, J.-C., Moya, A., & Hamdan, M. H. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.09.012 · Cited by 82
Sheldon, R., Talajic, M., Tang, A., Becker, G., Essebag, V., Sultan, O., Baranchuk, A., Ritchie, D., Morillo, C., Krahn, A., et al. (2022) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2021.10.003 · Cited by 32
Self-citation
Metadata
- Authors
- Baron-Esquivias, G., Morillo, C. A., Moya-Mitjans, A., Martinez-Alday, J., Ruiz-Granell, R., Lacunza-Ruiz, J., Garcia-Civera, R., Gutierrez-Carretero, E., & Romero-Garrido, R.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2017-10
- Volume
- 70
- Issue
- 14
- Pages
- 1720-1728
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2758957399
- Cited by
- 131
- References
- 11
- FWCI
- 13.14
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.