The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Pulsed Field Ablation of Paroxysmal Atrial Fibrillation
Open accessAbstract
OBJECTIVES: This study sought to determine whether durable pulmonary vein isolation (PVI) using pulsed field ablation (PFA) translates to freedom from atrial fibrillation recurrence without an increase in adverse events. BACKGROUND: PFA is a nonthermal ablative modality that, in preclinical studies, is able to preferentially ablate myocardial tissue with minimal effect on surrounding tissues. Herein, we present 1-year clinical outcomes of PFA. METHODS: In 3 multicenter studies (IMPULSE [A Safety and Feasibility Study of the IOWA Approach Endocardial Ablation System to Treat Atrial Fibrillation], PEFCAT [A Safety and Feasibility Study of the FARAPULSE Endocardial Ablation System to Treat Paroxysmal Atrial Fibrillation], and PEFCAT II [Expanded Safety and Feasibility Study of the FARAPULSE Endocardial Multi Ablation System to Treat Paroxysmal Atrial Fibrillation]), paroxysmal atrial fibrillation patients underwent PVI using a basket or flower PFA catheter. Invasive remapping was performed at ∼2 to 3 months, and reconnected PVs were reisolated with PFA or radiofrequency ablation. After a 90-day blanking period, arrhythmia recurrence was assessed over 1-year follow-up. RESULTS: In 121 patients, acute PVI was achieved in 100% of PVs with PFA alone. PV remapping, performed in 110 patients at 93.0 ± 30.1 days, demonstrated durable PVI in 84.8% of PVs (64.5% of patients), and 96.0% of PVs (84.1% of patients) treated with the optimized biphasic energy PFA waveform. Primary adverse events occurred in 2.5% of patients (2 pericardial effusions or tamponade, 1 hematoma); in addition, there was 1 transient ischemic attack. The 1-year Kaplan-Meier estimates for freedom from any atrial arrhythmia for the entire cohort and for the optimized biphasic energy PFA waveform cohort were 78.5 ± 3.8% and 84.5 ± 5.4%, respectively. CONCLUSIONS: PVI with a "single-shot" PFA catheter results in excellent PVI durability and acceptable safety with a low 1-year rate of atrial arrhythmia recurrence. These data mitigate concern that the nonthermal ablative mechanism of PFA might mask undiscovered compromises to clinical success. (IMPULSE: A Safety and Feasibility Study of the IOWA Approach Endocardial Ablation System to Treat Atrial Fibrillation, NCT03700385; A Safety and Feasibility Study of the FARAPULSE Endocardial Ablation System to Treat Paroxysmal Atrial Fibrillation, NCT03714178; PEFCAT II Expanded Safety and Feasibility Study of the FARAPULSE Endocardial Multi Ablation System to Treat Paroxysmal Atrial Fibrillation [PEFCAT II], NCT04170608).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation
Kuck, K.-H., Brugada, J., Fürnkranz, A., Metzner, A., Ouyang, F., Chun, K. R. J., Elvan, A., Arentz, T., Bestehorn, K., Pocock, S. J., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1602014 · Cited by 1,950
Tissue Ablation with Irreversible Electroporation
Davalos, R. V., Mir, L. M., & Rubinsky, B. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-8981-8 · Cited by 1,293
Irreversible Electroporation: A New Ablation Modality — Clinical Implications
Rubinsky, B., Onik, G., & Mikus, P. (2007) · Technology in Cancer Research & Treatment · doi:10.1177/153303460700600106 · Cited by 781
Pulsed Field Ablation for Pulmonary Vein Isolation in Atrial Fibrillation
Reddy, V. Y., Neuzil, P., Koruth, J. S., Petru, J., Funosako, M., Cochet, H., Sediva, L., Chovanec, M., Dukkipati, S. R., & Jais, P. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.04.021 · Cited by 700
Self-citationIn Vivo Results of a New Focal Tissue Ablation Technique: Irreversible Electroporation
Edd, J. F., Horowitz, L., Davalos, R. V., Mir, L. M., & Rubinsky, B. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873745 · Cited by 510
Cell membrane electroporation- Part 1: The phenomenon
Kotnik, T., Kramar, P., Pucihar, G., Miklavcic, D., & Tarek, M. (2012) · IEEE Electrical Insulation Magazine · doi:10.1109/mei.2012.6268438 · Cited by 475
Neuzil, P., Reddy, V. Y., Kautzner, J., Petru, J., Wichterle, D., Shah, D., Lambert, H., Yulzari, A., Wissner, E., & Kuck, K.-H. (2013) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.113.000374 · Cited by 434
Self-citationPulsed Field Ablation in Patients With Persistent Atrial Fibrillation
Reddy, V. Y., Anic, A., Koruth, J., Petru, J., Funasako, M., Minami, K., Breskovic, T., Sikiric, I., Dukkipati, S. R., Kawamura, I., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.07.007 · Cited by 418
Self-citationKautzner, J., Neuzil, P., Lambert, H., Peichl, P., Petru, J., Cihak, R., Skoda, J., Wichterle, D., Wissner, E., Yulzari, A., et al. (2015) · Europace · doi:10.1093/europace/euv057 · Cited by 374
Self-citationHussein, A., Das, M., Riva, S., Morgan, M., Ronayne, C., Sahni, A., Shaw, M., Todd, D., Hall, M., Modi, S., et al. (2018) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.118.006576 · Cited by 296
Santangeli, P., Zado, E. S., Hutchinson, M. D., Riley, M. P., Lin, D., Frankel, D. S., Supple, G. E., Garcia, F. C., Dixit, S., Callans, D. J., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2015.10.023 · Cited by 268
Predictors of Non-Pulmonary Vein Ectopic Beats Initiating Paroxysmal Atrial Fibrillation
Lee, S.-H., Tai, C.-T., Hsieh, M.-H., Tsao, H.-M., Lin, Y.-J., Chang, S.-L., Huang, J.-L., Lee, K.-T., Chen, Y.-J., Cheng, J.-J., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.06.016 · Cited by 266
Pulmonary Vein Isolation Using the Visually Guided Laser Balloon
Dukkipati, S. R., Cuoco, F., Kutinsky, I., Aryana, A., Bahnson, T. D., Lakkireddy, D., Woollett, I., Issa, Z. F., Natale, A., & Reddy, V. Y. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.07.036 · Cited by 212
Self-citationREDDY, V. Y., SEDIVA, L., PETRU, J., SKODA, J., CHOVANEC, M., CHITOVOVA, Z., DI STEFANO, P., RUBIN, E., DUKKIPATI, S., & NEUZIL, P. (2015) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12626 · Cited by 183
Self-citationNon Thermal Irreversible Electroporation: Novel Technology for Vascular Smooth Muscle Cells Ablation
Maor, E., Ivorra, A., & Rubinsky, B. (2009) · PLoS ONE · doi:10.1371/journal.pone.0004757 · Cited by 162
Dukkipati, S. R., Neužil, P., Kautzner, J., Petrů, J., Wichterle, D., Skoda, J., Cihak, R. J., Peichl, P., Russo, A. D., Pelargonio, G., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.01.019 · Cited by 154
Self-citationZhao, Y., Biase, L. D., Trivedi, C. G., Mohanty, S., Bai, R., Mohanty, P. K., Gianni, C., Santangeli, P., Horton, R., Sánchez, J., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.08.029 · Cited by 132
Miyazaki, S., Taniguchi, H., Hachiya, H., Nakamura, H., Takagi, T., Iwasawa, J., Hirao, K., & Iesaka, Y. (2016) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.115.003879 · Cited by 94
Iwasawa, J., Koruth, J. S., Petrů, J., Dujka, L., Královec, Š., Mzourkova, K., Dukkipati, S. R., Neužil, P., & Reddy, V. Y. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.06.008 · Cited by 87
Self-citationKuroki, K., Whang, W., Eggert, C., Lam, J., Leavitt, J., Kawamura, I., Reddy, A., Morrow, B., Schneider, C. W., Petrů, J., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2020.04.040 · Cited by 83
Self-citationKampaktsis, P. Ν., Oikonomou, E. K., Choi, D. H., & Cheung, J. W. (2017) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-017-0285-z · Cited by 60
Pulmonary Vein Re-Isolation as a Routine Strategy Regardless of Symptoms
Das, M., Wynn, G. J., Saeed, Y., Gomes, S., Morgan, M., Ronayne, C., Bonnett, L. J., Waktare, J. E. P., TODD, D. M., Hall, M. C. S., et al. (2017) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2017.01.016 · Cited by 57
Electroporation of epicardial autonomic ganglia: Safety and efficacy in medium‐term canine models
Padmanabhan, D., Naksuk, N., Killu, A. M., Kapa, S., Witt, C. M., Sugrue, A. M., DeSimone, C. V., Madhavan, M., de Groot, J. R., O’Brien, B., et al. (2019) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13860 · Cited by 42
Cited by
Pulsed Field or Conventional Thermal Ablation for Paroxysmal Atrial Fibrillation
Reddy, V. Y., Gerstenfeld, E. P., Natale, A., Whang, W., Cuoco, F. A., Patel, C., Mountantonakis, S. E., Gibson, D. N., Harding, J. D., Ellis, C. R., et al. (2023) · New England Journal of Medicine · doi:10.1056/nejmoa2307291 · Cited by 970
Self-citationTzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Sepehri Shamloo, A., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Europace · doi:10.1093/europace/euae043 · Cited by 634
Pulsed Field Ablation for the Treatment of Atrial Fibrillation: PULSED AF Pivotal Trial
Verma, A., Haines, D. E., Boersma, L. V., Sood, N., Natale, A., Marchlinski, F. E., Calkins, H., Sanders, P., Packer, D. L., Kuck, K.-H., et al. (2023) · Circulation · doi:10.1161/circulationaha.123.063988 · Cited by 613
Turagam, M. K., Neuzil, P., Schmidt, B., Reichlin, T., Neven, K., Metzner, A., Hansen, J., Blaauw, Y., Maury, P., Arentz, T., et al. (2023) · Circulation · doi:10.1161/circulationaha.123.064959 · Cited by 381
Self-citationSchmidt, B., Bordignon, S., Neven, K., Reichlin, T., Blaauw, Y., Hansen, J., Adelino, R., Ouss, A., Füting, A., Roten, L., et al. (2023) · Europace · doi:10.1093/europace/euad185 · Cited by 310
Metadata
- Authors
- Reddy, V. Y., Dukkipati, S. R., Neuzil, P., Anic, A., Petru, J., Funasako, M., Cochet, H., Minami, K., Breskovic, T., Sikiric, I., Sediva, L., Chovanec, M., Koruth, J., & Jais, P.
- Venue
- JACC: Clinical Electrophysiology
- Publisher
- Elsevier BV
- Published
- 2021-05
- Volume
- 7
- Issue
- 5
- Pages
- 614-627
- ISSN
- 2405-500X (ISSN-L)
- OpenAlex
- W3157697661
- Cited by
- 558
- References
- 25
- FWCI
- 48.73
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.