The DOI matches its Crossref record; 20 of the 21 references it cites were found in a registry or an index.
Clinical Validation of 5 Direct-to-Consumer Wearable Smart Devices to Detect Atrial Fibrillation
Open accessAbstract
Background Multiple smart devices capable to detect atrial fibrillation (AF) are presently available. Sensitivity and specificity for the detection of AF may differ between available smart devices, and this has not yet been adequately investigated. Objectives The aim was to assess the accuracy of 5 smart devices in identifying AF compared with a physician-interpreted 12-lead electrocardiogram as the reference standard in a real-world cohort of patients. Methods We consecutively enrolled patients presenting to a cardiology service at a tertiary referral center in a prospective, diagnostic study. Results We prospectively analyzed 201 patients (31% women, median age 66.7 years). AF was present in 62 (31%) patients. Sensitivity and specificity for the detection of AF were comparable between devices: 85% and 75% for the Apple Watch 6, 85% and 75% for the Samsung Galaxy Watch 3, 58% and 75% for the Withings Scanwatch, 66% and 79% for the Fitbit Sense, and 79% and 69% for the AliveCor KardiaMobile, respectively. The rate of inconclusive tracings (the algorithm was unable to determine the heart rhythm) was 18%, 17%, 24%, 21%, and 26% for the Apple Watch 6, Samsung Galaxy Watch 3, Withings Scan Watch, Fitbit Sense, and AliveCor KardiaMobile (P < 0.01 for pairwise comparison), respectively. By manual review of inconclusive tracings, the rhythm could be determined in 955 (99%) of 969 single-lead electrocardiograms. Regarding patient acceptance, the Apple Watch was ranked first (39% of participants). Conclusions In this clinical validation of 5 direct-to-consumer smart devices, we found differences in the amount of inconclusive tracings diminishing sensitivity and specificity of the smart devices. In a clinical setting, manual review of tracings is required in about one-fourth of cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“but the reliability of such tools is limited by the presence of noise in data collected from wearable and handheld devices12,13.”
From Detection of left ventricular systolic dysfunction from single-lead electrocardiography adapted for portable and wearable devices (2023) · cites this paper as [13]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Studies have shown high rates of poor signal quality among data recorded by wearable devices, and significant variation in quality across different manufacturers13.”
From Detection of left ventricular systolic dysfunction from single-lead electrocardiography adapted for portable and wearable devices (2023) · cites this paper as [13]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Go, A. S., Hylek, E. M., Phillips, K. A., Chang, Y., Henault, L. E., Selby, J. V., & Singer, D. E. (2001) · JAMA · doi:10.1001/jama.285.18.2370 · Cited by 6,205
Cuschieri, S. (2019) · Saudi Journal of Anaesthesia · doi:10.4103/sja.sja_543_18 · Cited by 4,331
Prevalence, incidence and lifetime risk of atrial fibrillation: the Rotterdam study
Heeringa, J., van der Kuip, D. A. M., Hofman, A., Kors, J. A., van Herpen, G., Stricker, B. H. C., Stijnen, T., Lip, G. Y. H., & Witteman, J. C. M. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi825 · Cited by 1,939
Large-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation
Perez, M. V., Mahaffey, K. W., Hedlin, H., Rumsfeld, J. S., Garcia, A., Ferris, T., Balasubramanian, V., Russo, A. M., Rajmane, A., Cheung, L., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1901183 · Cited by 1,917
Smart wearable devices in cardiovascular care: Where we are and how to move forward
Bayoumy, K., Gaber, M., Elshafeey, A., Mhaimeed, O., Dineen, E. H., Marvel, F. A., Martin, S. S., Muse, E. D., Turakhia, M. P., Tarakji, K. G., et al. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-021-00522-7 · Cited by 829
Halcox, J. P. J., Wareham, K., Cardew, A., Gilmore, M., Barry, J. P., Phillips, C., & Gravenor, M. B. (2017) · Circulation · doi:10.1161/circulationaha.117.030583 · Cited by 580
Smartwatch Algorithm for Automated Detection of Atrial Fibrillation
Bumgarner, J. M., Lambert, C. T., Hussein, A. A., Cantillon, D. J., Baranowski, B., Wolski, K., Lindsay, B. D., Wazni, O. M., & Tarakji, K. G. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.03.003 · Cited by 446
Accuracy of wrist-worn heart rate monitors
Wang, R., Blackburn, G., Desai, M., Phelan, D., Gillinov, L., Houghtaling, P., & Gillinov, M. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2016.3340 · Cited by 386
Lakkireddy, D., Chung, M. K., Gopinathannair, R., Patton, K. K., Gluckman, T. J., Turagam, M. K., Cheung, J. W., Patel, P. J., Sotomonte, J. C., Lampert, R. J., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2020.03.028 · Cited by 262
The WATCH AF trial: SmartWATCHes for detection of atrial fibrillation
Dörr, M., Nohturfft, V., Brasier, N., Bosshard, E., Djurdjevic, A., Gross, S., Raichle, C. J., Rhinisperger, M., Stöckli, R., & Eckstein, J. (2019) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2018.10.006 · Cited by 245
Flagged first, then by citations
1 of the 21 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Items 101–174 of 174
Smartwatch and wearable detection of atrial fibrillation: Current evidence and clinical implications
Davies, M., Bulluck, H., & Tayebjee, M. H. (2026) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2026.08.003 · Cited by 1
Ikeda, T., Ashihara, T., Iwasaki, Y., Ono, M., Kagiyama, N., Kimura, T., KUSANO, K. F., Kohno, R., Saku, K., Sasano, T., et al. (2024) · Japanese Journal of Electrocardiology · doi:10.5105/jse.44.275 · Cited by 1
A Review of Consumer-Grade Wrist-Worn Wearables for AI-Based Health Monitoring and Early Warning
Wang, M. (2025) · MedScien · doi:10.61173/ymbx2s09 · Cited by 1
Sharma, P., Sharma, P., Sharma, K. H., & Sojitra, P. N. (2025) · Cureus Journal of Computer Science. · doi:10.7759/s44389-025-10001-6 · Cited by 1
Szőnyi, M. D., Gausz, F. D., Bocz, B., Pilecky, D., Muk, B., Bánfi‐Bacsárdi, F., Földesi, C., Andreka, P. G., Szili‐Törok, T., Kupó, P., et al. (2026) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztag009 · Cited by 1
Borrelli, N., Sabatino, J., Repilado, F. J. R., Tutarel, O., Giannakoulas, G. A., D’Alto, M., Romeo, E., Tobler, D. A., & Diller, G. (2025) · European Heart Journal Supplements · doi:10.1093/eurheartjsupp/suaf086 · Cited by 1
Digital health in cardiovascular medicine: a comprehensive review
Fortuni, F., Ciliberti, G., Franchin, L., Angelini, F., Vitale, E., Albani, S., Cangemi, S., STOCCHI, E., Cornara, S., Doimo, S., et al. (2026) · Minerva Cardiology and Angiology · doi:10.23736/s2724-5683.25.07049-8 · Cited by 1
Advances in generative biology and bio-inspired artificial intelligence
Wen-Ye, Z. E. N. G., ZHENG, S.-Y., Xiao-Qin, Z. H. A. O., Zhu, W. A. N. G., ZHANG, Y.-J., & Zheng-Yuan, M. A. (2026) · Shengming kexue · doi:10.3724/cbls.2026038 · Cited by 1
Rantula, O., Lipponen, J. A., Halonen, J., Jäntti, H., Rissanen, T. T., Tarvainen, M. P., Naukkarinen, N. S., Väliaho, E., Santala, O. E., Sedha, J., et al. (2026) · JMIR mhealth and uhealth · doi:10.2196/82475 · Cited by 1
Bladon, S., Ainsworth, J. D., Cahuantzi, R., Cella, M., Drake, R., Eisner, E., Emsley, R., Faulkner, S., Greenwood, K., Gumley, A. I., et al. (2026) · JMIR Formative Research · doi:10.2196/86049 · Cited by 1
González-Landaeta, R., Mejia-Rodriguez, A. R., Dorantes-Méndez, G., & Flores, D. (2023) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-46933-6_37 · Cited by 1
Ishihara, Y., Ishizawa, M., Noma, T., Ohara, M., Tani, R., Kurashita, G., Toda, Y., Kobayashi, W., & Minamino, T. (2024) · Circulation Reports · doi:10.1253/circrep.cr-24-0008 · Cited by 1
Feature Factors that Influence Human Health in Smartwatches
William, W., Wiryawan, D., & Shaharudin, M. S. (2024) · IEEE Symposium on Industrial Electronics & Applications (ISIEA) · doi:10.1109/isiea61920.2024.10607243 · Cited by 1
Leveraging Smartwatch Technology for Rural Australian Health: Challenges and Opportunities
Leslie, A., Kovoor, J. J., & Bacchi, S. (2024) · Heart Lung and Circulation · doi:10.1016/j.hlc.2024.04.309 · Cited by 1
Asada, Y., Kudo, Y., Ito, T., & Kanda, H. (2024) · Scientific Reports · doi:10.1038/s41598-024-74157-2 · Cited by 2
Lee, H. J., Lee, S. H., Kim, J.-W., Kim, J. Y., Park, S., Park, K., & On, Y. K. (2024) · Scientific Reports · doi:10.1038/s41598-024-73989-2 · Cited by 1
Heringer, G. V., & Vinson, D. R. (2024) · International Journal of Emergency Medicine · doi:10.1186/s12245-024-00716-z · Cited by 1
Jeder sollte im Alter über 65 Jahre eine Smartwatch tragen
Johnson, V., & Eckardt, L. (2024) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-024-01058-2 · Cited by 1
Rytkin, E., Zotova, I. V., PASSMAN, R. S., Av, A., Trachiotis, G., Efimov, I. R., & Knight, B. P. (2025) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-025-01994-0 · Cited by 1
Kankula, R. R. (2025) · International Journal of Scientific Research in Computer Science Engineering and Information Technology · doi:10.32628/cseit251112342 · Cited by 1
Barrera, N. I., Jimenez, Y., & de Carvalho, G. D. (2026) · JACC Advances · doi:10.1016/j.jacadv.2026.102711 · Cited by 1
Contemporary wearable and handheld technology for the diagnosis of cardiac arrhythmias in Singapore
Chia, P., Tan, K. W. K., Ng, S., & Foo, D. C. G. (2023) · Singapore Medical Journal · doi:10.4103/singaporemedj.smj-2023-048
Chapa, J. J., & Bhakta, D. (2024) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2024.04.003
Smartwatches for Arrhythmia Detection and Management
Kim, C. H., Marvel, F. A., Majmudar, A., Horstman, N. A., SPRAGG, D. D., Calkins, H. G., Donnellan, E., Martin, S. S., & Isakadze, N. (2024) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-024-01040-8
Pelliccia, F., Zimarino, M., Giordano, M., & Dobrev, D. (2024) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztae046
Clinical implication of polysomnography findings for predicting atrial fibrillation
Kataoka, N., & Imamura, T. (2024) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2024.153770
Patient Driven EKG Device Performance in Adults with Fontan Palliation
Laubham, M., Dodeja, A. K., Kumthekar, R. N., Shay, V., D'Emilio, N., Conroy, S., Mah, M. L., Alvarado, C., & Kamp, A. N. (2024) · Pediatric Cardiology · doi:10.1007/s00246-024-03614-6
Rhythm-Ready: Harnessing Smart Devices to Detect and Manage Arrhythmias
Hsieh, P. N., & Singh, J. P. (2024) · Current Cardiology Reports · doi:10.1007/s11886-024-02135-1
High Sensitivity Resistive Vibration Sensing: Optimization for Wearable Heart Rate Monitoring
Abeeleh, A. A., Albagdady, A., Al‐Mahmodi, M., Al‐Shishani, G., & Al-Halhouli, A. T. (2024) · International Conference on Research and Education in Mechatronics (REM) · doi:10.1109/rem63063.2024.10735693
"Diagnosis of Cardiac Disease and Panic Attacks: Through Wearable ECG Monitoring" (Preprint)Preprint
Oh, H., Maeng, C., Park, J., Do, H., & Yoon, T. (2024) · doi:10.2196/preprints.68868
Kato, M., Kawatani, S., Tomomori, T., Okamura, A., Kotake, Y., Aoyama, K., Akagi, J., Okuda, S., Hayashi, S., & Yamamoto, K. (2024) · Circulation Journal · doi:10.1253/circj.cj-24-0815
Darrieux, F., & Wu, T. C. (2024) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20240662
Darrieux, F., & Wu, T. C. (2024) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20240662i
Daghlas, S., Evans, S., Holder, R., & McGreevy, S. (2025) · BMJ Case Reports · doi:10.1136/bcr-2024-263933
Wiederkehr, C., Müller, A. S., Igual, M., & Bernheim, A. M. (2025) · European Heart Journal - Case Reports · doi:10.1093/ehjcr/ytaf177
Capabilities and clinical utility of commercially available vital signs recorders
Mitkowski, P. P. (2025) · In a good rythm · doi:10.5604/01.3001.0055.0129
Single-Lead Mobile ECGs in Patients With Cardiovascular Disease
Steinberg, B. A. (2025) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2025.05.026
Doggart, P., Bond, R., Finlay, D., Guldenring, D., Albert, D., & Kennedy, A. (2025) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2025.154082
Cheung, C. C., Chyou, J. Y., Baykaner, T., Elshazly, M. B., Hyman, M. C., Lambrakos, L. K., Lobban, T., Mehta, N. K., Michaud, G. F., Navara, R., et al. (2025) · Heart Rhythm · doi:10.1016/j.hrthm.2025.07.056
Chagas, G. F., Bossan, M. C., & Nadal, J. (2025) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-94934-0_22
de Jesus, B. L. D. N., Anjos, C. N. D. S., Giacomim, G. S. P., de Souza, J. R., Pereira, J. M. C., Anjos, J. L., da Silva, L. P. N., Belo, M. D. L. R. D. S., Soares, S. D. S., & Sousa, T. N. (2025) · Asclepius International Journal of Scientific Health Science · doi:10.70779/aijshs.v4i10.368
Technology for better adult congenital heart disease care: the time is now
Blake, S. R., & Gatzoulis, M. A. (2025) · Open Heart · doi:10.1136/openhrt-2025-003766
Başkurt, A. A., Yurdam, F. S., Namazova, S. R., Bakır, E. O., Demir, Y., Öztürk, A. C., Çiftçi, Y., & Şenöz, O. (2025) · Kardiologiia · doi:10.18087/cardio.2025.11.n2946
Chest-Worn Device for Simultaneous Detection of Phonocardiogram and Electrocardiogram
Mata-Guzman, A., & González-Landaeta, R. (2026) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-032-13722-7_20
Senanayake, S. M. N. A. (2026) · Lecture notes in electrical engineering · doi:10.1007/978-3-032-10898-2_46
Clinical evaluation of a spot-check ECG for the diagnosis of atrial fibrillation
Lambert, C. T., Ganji, J., Alghazi, A., Good, W. W., Ghafoori, E., Cantillon, D. J., & Drury, P. (2026) · Heart Rhythm O2 · doi:10.1016/j.hroo.2026.01.006
Wearable Guardians: How Smartwatches and Smartphones are Transforming Atrial Fibrillation Screening
Garg, R. (2026) · Indian Journal of Clinical Cardiology · doi:10.1177/26324636251414493
Pérez, D. B., Urbistondo, C. M., & de Jalón, P. I. G. (2026) · Actualización en Medicina de Familia · doi:10.55783/amf.220202
Haque, M., Rony, R. I., Mustak, M. S., & Khalil, M. I. (2026) · International Conference on Electrical, Computer & Telecommunication Engineering (ICECTE) · doi:10.1109/icecte69292.2026.11429390
S.Jayakrishnan, & Kumar, J. A. (2025) · International Conference on Signal Processing, Computation, Electronics, Power and Telecommunication (IConSCEPT) · doi:10.1109/iconscept66142.2025.11436345
Trí tuệ nhân tạo trong sàng lọc và quản lý rối loạn nhịp tim
Nguyễn, K. T., Hoang, A. L. T., & Huỳnh, V. M. (2025) · Tạp chí Tim Mạch Học Việt Nam · doi:10.58354/jvc.115.2025.916
Methodological Inconsistency in Comparing Wearable Device Accuracy for Atrial Fibrillation Detection
Doggart, P. (2026) · JACC Advances · doi:10.1016/j.jacadv.2026.102709
Kim, M. J., Eom, S., Kim, J., Park, S.-J., Park, K., On, Y. K., Joo, S., Chang, M., Na, Y., Park, M., et al. (2026) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztag086
Dobrosielska, A., Woźniakowska, I., Zambrzycka, M., Misarko, A., Jedwabnik, M., Ścigała, S., Peszuk, K., Lech, W., Krajewski, H. V., & Olszewski, B. (2026) · Quality in Sport · doi:10.12775/qs.2026.58.72660
Assessment of Measuring Heart Rate Variability Using the MAX ECG MONITOR
Braeckeleer, L. D. (2026) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-032-24045-3_7
DIAGNÓSTICO PRECOCE DE DISTÚRBIOS CARDÍACOS POR SMARTWATCHES: UMA REVISÃO SISTEMÁTICA
Chaves, V. C. C., de Aguiar, A. D. M., Gonçalves, A. G. G., Ribeiro, A. D. R. B., Nascimento, G. B. V., Costa, G. R., Estolano, G. T., Ramos, G. N., Oliveira, H. K. S. T., Simão, L. M. D., et al. (2026) · Revista Foco · doi:10.54751/revistafoco.v19n7-018
Lin, C., Liu, W., Chen, K., Tsai, D., Chang, D.-W., Tsai, T.-N., Cheng, C.-C., Lin, C.-Y., Chen, Y.-H., Chien-Sung, T., et al. (2026) · npj Digital Medicine · doi:10.1038/s41746-026-02919-5 · Cited by 1
Patient Priorities for Digital Biomarkers in Cardiovascular Risk Management: Survey Study (Preprint)Preprint
Haring, N. L., Timmis, J. K., van den Broek, T., Schorr, K. A., Steller, A., Hulsen, J., Schoone-Harmsen, M. A., Wopereis, S., van der Loo, W. P. M., Zippel‐Schultz, B., et al. (2026) · doi:10.2196/preprints.106357
WEARABLE TECHNOLOGIES IN CARDIOVASCULAR RISK MONITORING: A LITERATURE REVIEW OF CLINICAL EVIDENCE
Ostruszka, N., Marusińska, M., Karpiński, M., Parzniewski, M., Czyz, W., Markiewicz, W., Kolawa, S., Borowiec, A., Pilecka, J., & Wojciechowski, J. (2026) · International Journal of Innovative Technologies in Social Science · doi:10.31435/ijitss.2(50).2026.5760
Alavi, R., Li, J., Matthews, R. V., Pahlevan, N. M., Kloner, R. A., & Gharib, M. (2026) · medRxiv · doi:10.64898/2026.07.08.26357521
Beyls, C., Hermida, A., Mollet, N., Vermander, M., Noe, F., Bara, H., Josse, E., Khamari, M., Diouf, M., Arab, O. A., et al. (2026) · BMJ Open · doi:10.1136/bmjopen-2026-118691
Wearable devices in atrial fibrillation: screening, monitoring, and management
Chen, W., Lin, X., Jia, P., & Liu, Z. (2026) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2026.1887788
Aylı, B. I. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-43874-5.00005-7
The throne of health care: detection of cardiac arrhythmias on a toilet-seat
Thilo, C., Achenbach, S., Lueg, C., Kochinke, L., Kaufmann, J., Pfeiffer, N., Lang-Richter, N. R., Zech, T. S., Steiner, A., Fiedelak, S., et al. (2026) · Clinical Research in Cardiology · doi:10.1007/s00392-026-03000-7
WEARABLE HEALTH TECHNOLOGIES AND THE MEDICALIZATION OF EVERYDAY LIFE: A SOCIO-MEDICAL REVIEW
Sierant, M., Kwaśniewska, M., Zmysłowska, K., Hajdaniak, A., Kiersztyn, J. M., Grabowska, A., Seńcio, N., Szatkowska, A., & Stadnik, K. A. (2026) · International Journal of Innovative Technologies in Social Science · doi:10.31435/ijitss.3(51).2026.6462
Aminorroaya, A., Shankar, S. V., Khan, M., Carter, M., Dhingra, L. S., Khunte, A., Lombo, B., McNamara, R. L., Oikonomou, E. K., Pedroso, A. F., et al. (2026) · medRxiv · doi:10.64898/2026.09.14.26361683
Vrdoljak, J., & Racz, D. A. (2026) · Sensors · doi:10.3390/s26185905
Artificial intelligence in cardiology: an evidence map across subspecialties, 2014–26
Koltowski, L., Basza, M., Soliński, M., Rolek, B., Brandberg, H., Costa, F., Keser, N., Marketou, M. E., Grabowski, M., Vidal-Pérez, R., et al. (2026) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztag152
Atrial Fibrillation in Athletes: Evaluation, Management and Prognostic Considerations
Tyndall, N., Dean, J. H., & Kisling, A. J. (2026) · Cardiology and cardiovascular medicine. · doi:10.5772/intechopen.1016350
Development of an efficient deep learning model for arrhythmia detection from consumer smartwatches
George, D.-C., Hulubeac, M.-A., Grămadă, Ş.-L., Balint, Z., & Diosan, L. (2026) · Frontiers in Artificial Intelligence · doi:10.3389/frai.2026.1882739
Edder, A., Ben-Bouazza, F.-E., Bigane, Y. A., Sangare, D., Tafala, I., Manchadi, O., & Jioudi, B. (2026) · BioMedInformatics · doi:10.3390/biomedinformatics6050090
Radke, P. W., Dimde, L., Ebermann, T., Glück, S., Goss, F., Köhler, F., Martens, E., Meder, B., Nowak, B., Perings, C. A., et al. (2026) · Die Kardiologie · doi:10.1007/s12181-026-00841-4
Pieczara, S., Musiał, P., Nowicki, W., Machaj, D., Stańko, M., Stefanik, Z., & Urbanowicz, P. (2026) · Journal of Education Health and Sport · doi:10.12775/jehs.2026.95.76576
Metadata
- Authors
- Mannhart, D., Lischer, M., Knecht, S., du Fay de Lavallaz, J., Strebel, I., Serban, T., Vögeli, D., Schaer, B., Osswald, S., Mueller, C., Kühne, M., Sticherling, C., & Badertscher, P.
- Affiliations
- University of Basel (CH)
- Corresponding author
- Badertscher, Patrick
- ORCID
- Venue
- JACC: Clinical Electrophysiology
- Publisher
- Elsevier BV
- Published
- 2023-02
- Volume
- 9
- Issue
- 2
- Pages
- 232-242
- ISSN
- 2405-500X (ISSN-L)
- OpenAlex
- W4317376731
- Cited by
- 175
- References
- 21
- Citations by year
- 2026: 41 · 2025: 63 · 2024: 52 · 2023: 19
- FWCI
- 34.75
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- JACC. Clinical electrophysiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Beckman Coulter Foundation
- Boston Scientific Corporation
- MicroPort
- Pfizer
- Freiwillige Akademische Gesellschaft
- AstraZeneca
- Knowles Teacher Initiative
- Bayer
- Universitätsspital Basel
- Biotronik
- Universität Basel
- Sphingotec GmbH
- Abbott Laboratories
- Medtronic
- Daiichi-Sankyo
- Biosense Webster
- Schweizerische Herzstiftung
- Foundation for Cardiovascular Research
- Siemens
- Boehringer Ingelheim
- Amgen
- Singulex
- Roche
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
- Johnson and Johnson
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- atrial fibrillation, wearable smart devices, Apple Watch, single-lead ECG, device accuracy, sensitivity and specificity, patient acceptance
- MeSH terms
- Wearable Electronic Devices, Aged, Algorithms, Atrial Fibrillation, Electrocardiography, Female, Humans, Male, Prospective Studies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review