Utility of the Fitbit Flex to evaluate sleep in major depressive disorder: A comparison against polysomnography and wrist-worn actigraphy
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Background Sleep disturbance is a common and important component of affective illness. Fitness activity trackers are emerging as alternative means to estimate sleep in psychiatric patients; however, their ability to quantify sleep in mood disorders has not been empirically evaluated. Thus, this study sought to evaluate the utility of the Fitbit Flex (FBF) to estimate sleep in patients with major depressive disorder (MDD) relative to gold standard polysomnography (PSG) and a widely-used actigraph (Actiwatch-2; AW-2). Methods Twenty-one patients with unipolar MDD wore the FBF and AW-2 during in-laboratory PSG. Bland-Altman analysis compared sleep variables among devices. Epoch-by-epoch analysis further evaluated sensitivity, specificity, and accuracy for the FBF and AW-2 relative to PSG. Results The FBF demonstrated significant limitations in quantifying sleep and wake, relative to PSG. In the normal setting, the FBF significantly overestimated sleep time and efficiency, and displayed poor ability to correctly identify wake epochs (i.e. low specificity). In the sensitive setting, the FBF significantly underestimated sleep time and efficiency relative to PSG. Performance characteristics of the FBF were more similar to the AW-2 in the normal compared to sensitive setting. Limitations Participants were young to middle aged and predominantly female, which may limit generalizability of findings. Study design also precluded ability to assess longitudinal performance of FBF. Conclusions The FBF is not an adequate substitute for PSG when quantifying sleep in MDD, and the settings of the device sizably impact its performance relative to PSG and other standard actigraphs. The limitations and capabilities of the FBF should be carefully considered prior to clinical and research implementation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Validation of the Insomnia Severity Index as an outcome measure for insomnia research
Bastien, C. (2001) · Sleep Medicine · doi:10.1016/s1389-9457(00)00065-4 · Cited by 8,067 · cited 3×
“, 1989), and Insomnia Severity Index (ISI) (Bastien et al., 2001).”
BackgroundMethodInfluentialBeck, A. T., Steer, R. A., & Brown, G. (2011) · PsycTESTS Dataset · doi:10.1037/t00742-000 · Cited by 7,535
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Baglioni, C., Battagliese, G., Feige, B., Spiegelhalder, K., Nissen, C., Voderholzer, U., Lombardo, C., & Riemann, D. (2011) · Journal of Affective Disorders · doi:10.1016/j.jad.2011.01.011 · Cited by 2,779
Sleep and Psychiatric Disorders: A Meta-analysis
Benca, R. M. (1992) · Archives of General Psychiatry · doi:10.1001/archpsyc.1992.01820080059010 · Cited by 1,468 · cited 1×
“Objective changes in sleep continuity and duration in MDD, as measured by polysomnography, are robust physiological indicators of sleep disturbance in the disorder (Benca et al., 1992; Steiger and Kimura, 2010; Pillai et al., 2011; Plante et al., 2017).”
BackgroundMorgenthaler, T., Alessi, C., Friedman, L., Owens, J., Kapur, V., Boehlecke, B., Brown, T., Chesson, A., Coleman, J., Lee-Chiong, T., et al. (2007) · Sleep · doi:10.1093/sleep/30.4.519 · Cited by 1,142
Tsuno, N., Besset, A., & Ritchie, K. (2005) · The Journal of Clinical Psychiatry · doi:10.4088/jcp.v66n1008 · Cited by 1,084
Marino, M., Li, Y., Rueschman, M. N., Winkelman, J. W., Ellenbogen, J. M., Solet, J. M., Dulin, H., Berkman, L. F., & Buxton, O. M. (2013) · Sleep · doi:10.5665/sleep.3142 · Cited by 1,056
Primary insomnia: a risk factor to develop depression?
Riemann, D. (2003) · Journal of Affective Disorders · doi:10.1016/s0165-0327(02)00072-1 · Cited by 641 · cited 2×
“…with treatment resistance, symptomatic relapse, suicidality, and impaired daytime function, underscoring its importance in the course of affective illness (Baglioni et al., 2011; McCall et al., 2010; Nadorff et al., 2013; Perlis et al., 1997; Riemann and Voderholzer, 2003; Szklo-Coxe et al., 2010).”
BackgroundMantua, J., Gravel, N., & Spencer, R. (2016) · Sensors · doi:10.3390/s16050646 · Cited by 314 · cited 1×
“Contrary to the results of these investigations, one study in healthy, young adults demonstrated comparable results in estimation of total sleep time for multiple fitness activity trackers, relative to PSG (Mantua et al., 2016).”
Result
Cited by
Accuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C. (2018) · JMIR mHealth and uHealth · doi:10.2196/10527 · Cited by 616
“On the other hand, 1 study examined total sleep time and sleep efficiency in the sensitive sleep mode, reporting Fitbit underestimation of both by more than 15% [82].”
BackgroundWearable Sleep Technology in Clinical and Research Settings
DE ZAMBOTTI, M., CELLINI, N., GOLDSTONE, A., COLRAIN, I. M., & BAKER, F. C. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001947 · Cited by 564
Henriksen, A., Haugen Mikalsen, M., Woldaregay, A. Z., Muzny, M., Hartvigsen, G., Hopstock, L. A., & Grimsgaard, S. (2018) · Journal of Medical Internet Research · doi:10.2196/jmir.9157 · Cited by 542
“Fitbit devices were used in 54 studies [9,13,28-79].”
MethodAccuracy of Wristband Fitbit Models in Assessing Sleep: Systematic Review and Meta-Analysis
Haghayegh, S., Khoshnevis, S., Smolensky, M. H., Diller, K. R., & Castriotta, R. J. (2019) · Journal of Medical Internet Research · doi:10.2196/16273 · Cited by 446
“…were diverse: normal sleepers as well as persons diagnosed with periodic limb movement in sleep (PLMS) [28], obstructive sleep apnea, sleep-disordered breathing [30], central disorders of hypersomnolence [26], insomnia [31], and depression [25], and Huntington disease gene carriers [38].”
InfluentialA validation study of Fitbit Charge 2™ compared with polysomnography in adults
de Zambotti, M., Goldstone, A., Claudatos, S., Colrain, I. M., & Baker, F. C. (2018) · Chronobiology International · doi:10.1080/07420528.2017.1413578 · Cited by 413
Depner, C. M., Cheng, P. C., Devine, J. K., Khosla, S., de Zambotti, M., Robillard, R., Vakulin, A., & Drummond, S. P. A. (2020) · Sleep · doi:10.1093/sleep/zsz254 · Cited by 245
Baron, K. G., Duffecy, J., Berendsen, M. A., Cheung Mason, I., Lattie, E. G., & Manalo, N. C. (2018) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2017.12.002 · Cited by 186
“[16] Utility of the Fitbit Flex to evaluate sleep in major”
Cao, R., Azimi, I., Sarhaddi, F., Niela-Vilen, H., Axelin, A., Liljeberg, P., & Rahmani, A. M. (2022) · Journal of Medical Internet Research · doi:10.2196/27487 · Cited by 159
Current advances in wearable devices and their sensors in patients with depression
Lee, S., Kim, H., Park, M. J., & Jeon, H. J. (2021) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2021.672347 · Cited by 117
Liang, Z., & Chapa-Martell, M. A. (2019) · JMIR mHealth and uHealth · doi:10.2196/13384 · Cited by 76
“In the meantime, researchers and clinicians are increasingly adopting consumer wristbands, such as Fitbit devices, as outcome measurement tools in research studies [6,8-14].”
Ng, A., Reddy, M., Zalta, A. K., & Schueller, S. M. (2018) · JMIR Mental Health · doi:10.2196/10415 · Cited by 37
Metadata
- Authors
- Cook, J. D., Prairie, M. L., & Plante, D. T.
- Venue
- Journal of Affective Disorders
- Publisher
- Elsevier BV
- Published
- 2017-08
- Volume
- 217
- Pages
- 299-305
- ISSN
- 0165-0327 (ISSN-L)
- OpenAlex
- W2606806373
- Cited by
- 104
- References
- 12
- FWCI
- 14.27
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.