On the biomechanics of heart valve function
Open accessThe DOI matches its Crossref record; 82 of the 82 references it cites were found in a registry or an index.
Abstract
Heart valves (HVs) are fluidic control components of the heart that ensure unidirectional blood flow during the cardiac cycle. However, this description does not adequately describe the biomechanical ramifications of their function in that their mechanics are multi-modal. Moreover, they must replicate their cyclic function over an entire lifetime, with an estimated total functional demand of least 3×109 cycles. The focus of the present review is on the functional biomechanics of heart valves. Thus, the focus of the present review is on functional biomechanics, referring primarily to biosolid as well as several key biofluid mechanical aspects underlying heart valve physiological function. Specifically, we refer to the mechanical behaviors of the extra-cellular matrix structural proteins, underlying cellular function, and their integrated relation to the major aspects of valvular hemodynamic function. While we focus on the work from the author’s laboratories, relevant works of other investigators have been included whenever appropriate. We conclude with a summary of important future trends.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · Cited by 15,411
Textbook of Medical Physiology
(1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,749
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart Failure
Rose, E. A., Gelijns, A. C., Moskowitz, A. J., Heitjan, D. F., Stevenson, L. W., Dembitsky, W., Long, J. W., Ascheim, D. D., Tierney, A. R., Levitan, R. G., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa012175 · Cited by 3,977
Writing Group Members, Thom, T., Haase, N., Rosamond, W., Howard, V. J., Rumsfeld, J., Manolio, T., Zheng, Z.-J., Flegal, K., O’Donnell, C., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.171600 · Cited by 3,451
Biomechanics: Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1981) · Journal of Biomechanical Engineering · doi:10.1115/1.3138285 · Cited by 2,769
(2016) · Lung Transplantation · doi:10.3109/9781439802571-25 · Cited by 2,157
Constitutive equations for fibrous connective tissues
Lanir, Y. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90041-6 · Cited by 741
Textbook of medical physiology
(1966) · American Heart Journal · doi:10.1016/0002-8703(66)90334-6 · Cited by 644
Mechanical stress mechanisms and the cell. An endothelial paradigm.
Davies, P. F., & Tripathi, S. C. (1993) · Circulation Research · doi:10.1161/01.res.72.2.239 · Cited by 629
Cited by
Soft Materials by Design: Unconventional Polymer Networks Give Extreme Properties
Zhao, X., Chen, X., Yuk, H., Lin, S., Liu, X., & Parada, G. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01088 · Cited by 1,161
Heart Valve Structure and Function in Development and Disease
Hinton, R. B., & Yutzey, K. E. (2011) · Annual Review of Physiology · doi:10.1146/annurev-physiol-012110-142145 · Cited by 498
Duan, B., Kapetanovic, E., Hockaday, L. A., & Butcher, J. T. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.12.005 · Cited by 436
Calcific aortic valve disease: mechanisms, prevention and treatment
Moncla, L.-H. M., Briend, M., Bossé, Y., & Mathieu, P. (2023) · Nature Reviews Cardiology · doi:10.1038/s41569-023-00845-7 · Cited by 306
Chen, J.-H., & Simmons, C. A. (2011) · Circulation Research · doi:10.1161/circresaha.110.234237 · Cited by 289
Biomechanical properties of native and tissue engineered heart valve constructs
Hasan, A., Ragaert, K., Swieszkowski, W., Selimović, Š., Paul, A., Camci-Unal, G., Mofrad, M. R. K., & Khademhosseini, A. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.09.023 · Cited by 279
Substrates for cardiovascular tissue engineering
Bouten, C. V. C., Dankers, P. Y. W., Driessen-Mol, A., Pedron, S., Brizard, A. M. A., & Baaijens, F. P. T. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.01.007 · Cited by 261
Dynamic covalent hydrogels as biomaterials to mimic the viscoelasticity of soft tissues
Tang, S., Richardson, B. M., & Anseth, K. S. (2021) · Progress in Materials Science · doi:10.1016/j.pmatsci.2020.100738 · Cited by 261
Bioengineering Challenges for Heart Valve Tissue Engineering
Sacks, M. S., Schoen, F. J., & Mayer, J. E. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124903 · Cited by 256
Self-citationBiologically Inspired Scaffolds for Heart Valve Tissue Engineering via Melt Electrowriting
Saidy, N. T., Wolf, F., Bas, O., Keijdener, H., Hutmacher, D. W., Mela, P., & De‐Juan‐Pardo, E. M. (2019) · Small · doi:10.1002/smll.201900873 · Cited by 215
Cyclic strain induces dual-mode endothelial-mesenchymal transformation of the cardiac valve
Balachandran, K., Alford, P. W., Wylie-Sears, J., Goss, J. A., Grosberg, A., Bischoff, J., Aikawa, E., Levine, R. A., & Parker, K. K. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1106954108 · Cited by 176
“C valves are sophisticated structures that function in a complex mechanical environment, opening and closing more than 3 billion times during the average human lifetime (1).”
BackgroundInfluentialEngineering hybrid polymer-protein super-aligned nanofibers via rotary jet spinning
Badrossamay, M. R., Balachandran, K., Capulli, A. K., Golecki, H. M., Agarwal, A., Goss, J. A., Kim, H., Shin, K., & Parker, K. K. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2013.12.072 · Cited by 173
“Further, the Young’s modulus and maximum strain of the PCL/Collagen scaffold is on the same order of magnitude as cardiac muscle and heart valve leaflets [39], suggesting their suitability for cardiovascular tissue engineering applications.”
BackgroundFabricating hydrogels to mimic biological tissues of complex shapes and high fatigue resistance
Yang, H., Ji, M., Yang, M., Shi, M., Pan, Y., Zhou, Y., Qi, H. J., Suo, Z., & Tang, J. (2021) · Matter · doi:10.1016/j.matt.2021.03.011 · Cited by 159
Fibrous scaffolds for building hearts and heart parts
Capulli, A. K., MacQueen, L. A., Sheehy, S. P., & Parker, K. K. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.11.020 · Cited by 130
“Native biaxial pulmonary valve stiffness Circumferential (kPa) Low-strain (0–18%): 11.31 ± 0.79 Mid-strain (18–28%): 408.23 ± 18.34 High strain (28–35%): 1457.19 ± 58.1 Radial (kPa) Low-strain (0–18%): 11.67 ± 0.61 Mid-strain (18–28%): 50.16 ± 2.01 High strain (28–35%): 172.44 ± 5.24 [154] Load durability 40 million l…”
InfluentialHeart Valve Development, Maintenance, and Disease
Tao, G., Kotick, J. D., & Lincoln, J. (2012) · Current Topics in Developmental Biology · doi:10.1016/b978-0-12-387786-4.00006-3 · Cited by 89
Snyder, Y., & Jana, S. (2023) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.2c01430 · Cited by 15
Yoo, J., Chung, G., & Park, Y. (2025) · Advanced Materials · doi:10.1002/adma.202419504 · Cited by 13
Metadata
- Authors
- Sacks, M. S., David Merryman, W., & Schmidt, D. E.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2009-08
- Volume
- 42
- Issue
- 12
- Pages
- 1804-1824
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W1988071888
- Cited by
- 372
- References
- 82
- FWCI
- 15.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.