CoChat

Lipidomics by ultrahigh performance liquid chromatography-high resolution mass spectrometry and its application to complex biological samples

Open access
Triebl, Alexander, Trötzmüller, Martin, Hartler, Jürgen, Stojakovic, Tatjana, Köfeler, Harald C. · 2017 · Journal of Chromatography B
Cited by 107

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

An improved approach for selective and sensitive identification and quantitation of lipid molecular species using reversed phase chromatography coupled to high resolution mass spectrometry was developed. The method is applicable to a wide variety of biological matrices using a simple liquid-liquid extraction procedure. Together, this approach combines three selectivity criteria: Reversed phase chromatography separates lipids according to their acyl chain length and degree of unsaturation and is capable of resolving positional isomers of lysophospholipids, as well as structural isomers of diacyl phospholipids and glycerolipids. Orbitrap mass spectrometry delivers the elemental composition of both positive and negative ions with high mass accuracy. Finally, automatically generated tandem mass spectra provide structural insight into numerous glycerolipids, phospholipids, and sphingolipids within a single run. Method validation resulted in a linearity range of more than four orders of magnitude, good values for accuracy and precision at biologically relevant concentration levels, and limits of quantitation of a few femtomoles on column. Hundreds of lipid molecular species were detected and quantified in three different biological matrices, which cover well the wide variety and complexity of various model organisms in lipidomic research. Together with a reliable software package, this method is a prime choice for global lipidomic analysis of even the most complex biological samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jchromb.2017.03.027

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 71

  1. Fahy, 2005, A comprehensive classification system for lipids, J. Lipid Res., 46, 839, 10.1194/jlr.E400004-JLR200 · DOI · Paper page
  2. Fahy, 2008, Update of the LIPID MAPS comprehensive classification system for lipids, J. Lipid Res., 50, S9, 10.1194/jlr.R800095-JLR200 · DOI · Paper page
  3. Wenk, 2005, The emerging field of lipidomics, Nat. Rev. Drug Discov., 4, 594, 10.1038/nrd1776 · DOI · Paper page
  4. Köfeler, 2012, Mass spectrometry based lipidomics: an overview of technological platforms, Metabolites, 2, 19, 10.3390/metabo2010019 · DOI · Paper page
  5. Ejsing, 2006, Automated identification and quantification of glycerophospholipid molecular species by multiple precursor ion scanning, Anal. Chem., 78, 6202, 10.1021/ac060545x · DOI · Paper page
  6. Schwudke, 2006, Lipid profiling by multiple precursor and neutral loss scanning driven by the data-dependent acquisition, Anal. Chem., 78, 585, 10.1021/ac051605m · DOI · Paper page
  7. Ejsing, 2009, Global analysis of the yeast lipidome by quantitative shotgun mass spectrometry, Proc. Natl. Acad. Sci. U. S. A., 106, 2136, 10.1073/pnas.0811700106 · DOI · Paper page
  8. Kalvodova, 2009, The lipidomes of vesicular stomatitis virus semliki forest virus, and the host plasma membrane analyzed by quantitative shotgun mass spectrometry, J. Virol., 83, 7996, 10.1128/JVI.00635-09 · DOI · Paper page
  9. Schuhmann, 2011, Bottom-up shotgun lipidomics by higher energy collisional dissociation on LTQ Orbitrap mass spectrometers, Anal. Chem., 83, 5480, 10.1021/ac102505f · DOI
  10. Schwudke, 2011, Shotgun lipidomics on high resolution mass spectrometers, Cold Spring Harb. Perspect. Biol., 3, a004614, 10.1101/cshperspect.a004614 · DOI · Paper page
  11. Schuhmann, 2012, Shotgun lipidomics on a LTQ Orbitrap mass spectrometer by successive switching between acquisition polarity modes, J. Mass Spectrom., 47, 96, 10.1002/jms.2031 · DOI · Paper page
  12. Sandra, 2010, Comprehensive blood plasma lipidomics by liquid chromatography/quadrupole time-of-flight mass spectrometry, J. Chromatogr. A, 1217, 4087, 10.1016/j.chroma.2010.02.039 · DOI · Paper page
  13. Yang, 2009, Systematic analysis of choline-containing phospholipids using multi-dimensional mass spectrometry-based shotgun lipidomics, J. Chromatogr. B, 877, 2924, 10.1016/j.jchromb.2009.01.016 · DOI · Paper page
  14. a. Bowden, 2014, Development of an automated multi-injection shotgun lipidomics approach using a triple quadrupole mass spectrometer, Lipids, 49, 609, 10.1007/s11745-014-3903-x · DOI
  15. Wang, 2015, Comprehensive and quantitative analysis of lysophospholipid molecular species present in obese mouse liver by shotgun lipidomics, Anal. Chem., 87, 4879, 10.1021/acs.analchem.5b00410 · DOI
  16. Han, 2006, Factors influencing the electrospray intrasource separation and selective ionization of glycerophospholipids, J. Am. Soc. Mass Spectrom., 17, 264, 10.1016/j.jasms.2005.11.003 · DOI · Paper page
  17. Kliman, 2011, Lipid analysis and lipidomics by structurally selective ion mobility-mass spectrometry, Biochim. Biophys. Acta – Mol. Cell Biol. Lipids, 1811, 935, 10.1016/j.bbalip.2011.05.016 · DOI · Paper page
  18. a Shvartsburg, 2011, Separation and classification of lipids using differential ion mobility spectrometry, J. Am. Soc. Mass Spectrom., 22, 1146, 10.1007/s13361-011-0114-z · DOI
  19. Baker, 2014, Three-dimensional enhanced lipidomics analysis combining UPLC, differential ion mobility spectrometry, and mass spectrometric separation strategies, J. Lipid Res, 55, 2432, 10.1194/jlr.D051581 · DOI
  20. Lintonen, 2014, Differential mobility spectrometry-driven shotgun lipidomics, Anal. Chem., 86, 9662, 10.1021/ac5021744 · DOI
  21. Maccarone, 2014, Characterization of acyl chain position in unsaturated phosphatidylcholines using differential mobility-mass spectrometry, J. Lipid Res., 55, 1668, 10.1194/jlr.M046995 · doi:10.1194/jlr.m046995
  22. Groessl, 2015, High resolution ion mobility-mass spectrometry for separation and identification of isomeric lipids, Analyst, 140, 6904, 10.1039/C5AN00838G · DOI · Paper page
  23. a. Hankin, 2015, Ion mobility and tandem mass spectrometry of phosphatidylglycerol and bis(monoacylglycerol) phosphate (BMP), Int. J. Mass Spectrom., 378, 255, 10.1016/j.ijms.2014.08.026 · DOI
  24. Herzog, 2011, A novel informatics concept for high-throughput shotgun lipidomics based on the molecular fragmentation query language, Genome Biol., 12, R8, 10.1186/gb-2011-12-1-r8 · DOI · Paper page
  25. Hsu, 2005, Studies on phosphatidylserine by tandem quadrupole and multiple stage quadrupole ion-trap mass spectrometry with electrospray ionization: structural characterization and the fragmentation processes, J. Am. Soc. Mass Spectrom., 16, 1510, 10.1016/j.jasms.2005.04.018 · DOI
  26. Bollinger, 2010, Improved method for the quantification of lysophospholipids including enol ether species by liquid chromatography-tandem mass spectrometry, J. Lipid Res., 51, 440, 10.1194/jlr.D000885 · doi:10.1194/jlr.d000885
  27. Triebl, 2014, Quantitation of phosphatidic acid and lysophosphatidic acid molecular species using hydrophilic interaction liquid chromatography coupled to electrospray ionization high resolution mass spectrometry, J. Chromatogr. A, 1347, 104, 10.1016/j.chroma.2014.04.070 · DOI · Paper page
  28. Holčapek, 2012, Recent developments in liquid chromatography-mass spectrometry and related techniques, J. Chromatogr. A, 1259, 3, 10.1016/j.chroma.2012.08.072 · DOI · Paper page
  29. Bamba, 2012, Metabolic profiling of lipids by supercritical fluid chromatography/mass spectrometry, J. Chromatogr. A, 1250, 212, 10.1016/j.chroma.2012.05.068 · doi:10.1016/j.chroma.2012.05.068
  30. Lísa, 2015, High-throughput and comprehensive lipidomic analysis using ultrahigh-Performance supercritical fluid chromatography–mass spectrometry, Anal. Chem., 87, 7187, 10.1021/acs.analchem.5b01054 · DOI · Paper page
  31. Fauland, 2011, A comprehensive method for lipid profiling by liquid chromatography-ion cyclotron resonance mass spectrometry, J. Lipid Res., 52, 2314, 10.1194/jlr.D016550 · DOI
  32. Matyash, 2008, Lipid extraction by methyl-tert-butyl ether for high-throughput lipidomics, J. Lipid Res., 49, 1137, 10.1194/jlr.D700041-JLR200 · DOI · Paper page
  33. Jenkins, 2015, A review of odd-Chain fatty acid metabolism and the role of pentadecanoic acid (C15:0) and heptadecanoic acid (C17:0) in health and disease, Molecules, 20, 2425, 10.3390/molecules20022425 · DOI · Paper page
  34. Prasain, 2015, Comparative lipidomics of caenorhabditis elegans metabolic disease models by SWATH non-targeted tandem mass spectrometry, Metabolites, 5, 677, 10.3390/metabo5040677 · DOI
  35. Hartler, 2011, Lipid data analyzer: unattended identification and quantitation of lipids in LC-MS data, Bioinformatics, 27, 572, 10.1093/bioinformatics/btq699 · DOI · Paper page
  36. Griffiths, 2003, Tandem mass spectrometry in the study of fatty acids bile acids, and steroids, Mass Spectrom. Rev., 22, 81, 10.1002/mas.10046 · DOI · Paper page
  37. Murphy, 2007, Detection of the abundance of diacylglycerol and triacylglycerol molecular species in cells using neutral loss mass spectrometry, Anal. Biochem., 366, 59, 10.1016/j.ab.2007.03.012 · DOI · Paper page
  38. Hsu, 2009, Electrospray ionization with low-energy collisionally activated dissociation tandem mass spectrometry of glycerophospholipids: mechanisms of fragmentation and structural characterization, J. Chromatogr. B., 877, 2673, 10.1016/j.jchromb.2009.02.033 · DOI · Paper page
  39. Liebisch, 2013, Shorthand notation for lipid structures derived from mass spectrometry, J. Lipid Res., 54, 1523, 10.1194/jlr.M033506 · DOI · Paper page
  40. Volmer, 2014, Terms and acronyms that should be avoided in mass spectrometry publications, Rapid Commun. Mass Spectrom., 28, 1853, 10.1002/rcm.6979 · DOI
  41. Hsu, 2006, Characterization of cardiolipin from Escherichia coli by electrospray ionization with multiple stage quadrupole ion-trap mass spectrometric analysis of [M−2H+Na]- ions, J. Am. Soc. Mass Spectrom., 17, 420, 10.1016/j.jasms.2005.11.019 · doi:10.1016/j.jasms.2005.11.019
  42. Knittelfelder, 2014, A versatile ultra-high performance LC-MS method for lipid profiling, J. Chromatogr. B., 951–952, 119, 10.1016/j.jchromb.2014.01.011 · DOI · Paper page
  43. Holčapek, 2015, Continuous comprehensive two-dimensional liquid chromatography-electrospray ionization mass spectrometry of complex lipidomic samples, Anal. Bioanal. Chem., 407, 5033, 10.1007/s00216-015-8528-2 · DOI
  44. Triebl, 2016, Quantitative analysis of N-acylphosphatidylethanolamine molecular species in rat brain using solid-phase extraction combined with reversed-phase chromatography and tandem mass spectrometry, J. Sep. Sci., 39, 2474, 10.1002/jssc.201600172 · DOI
  45. Wakamatsu, 2005, A severe peak tailing of phosphate compounds caused by interaction with stainless steel used for liquid chromatography and electrospray mass spectrometry, J. Sep. Sci., 28, 1823, 10.1002/jssc.200400027 · DOI
  46. Asakawa, 2008, Suppression effects of carbonate on the interaction between stainless steel and phosphate groups of phosphate compounds in high-performance liquid chromatography and electrospray ionization mass spectrometry, J. Chromatogr. A, 1198–1199, 80, 10.1016/j.chroma.2008.05.015 · DOI
  47. Wakelam, 2014, The uses and limitations of the analysis of cellular phosphoinositides by lipidomic and imaging methodologies, Biochim. Biophys. Acta – Mol. Cell Biol. Lipids, 1841, 1102, 10.1016/j.bbalip.2014.04.005 · DOI
  48. Cífková, 2016, Hydrophilic interaction liquid chromatography-mass spectrometry of (lyso)phosphatidic acids, (lyso)phosphatidylserines and other lipid classes, J. Chromatogr. A, 1439, 65, 10.1016/j.chroma.2016.01.064 · doi:10.1016/j.chroma.2016.01.064
  49. Bang, 2013, On-line two-dimensional capillary strong anion exchange/reversed phase liquid chromatography–tandem mass spectrometry for comprehensive lipid analysis, J. Chromatogr. A, 1310, 82, 10.1016/j.chroma.2013.08.069 · DOI
  50. Sarafian, 2014, Objective set of criteria for optimization of sample preparation procedures for ultra-high throughput untargeted blood plasma lipid profiling by ultra performance liquid chromatography–mass spectrometry, Anal. Chem., 86, 5766, 10.1021/ac500317c · DOI · Paper page
  51. Ovčačíková, 2016, Retention behavior of lipids in reversed-phase ultrahigh-performance liquid chromatography–electrospray ionization mass spectrometry, J. Chromatogr. A, 1450, 76, 10.1016/j.chroma.2016.04.082 · DOI
  52. Lísa, 2011, Lipidomic profiling of biological tissues using off-line two-dimensional high-performance liquid chromatography-mass spectrometry, J. Chromatogr. A, 1218, 5146, 10.1016/j.chroma.2011.05.081 · DOI · Paper page
  53. Creer, 1985, Separation of isomeric lysophospholipids by reverse phase HPLC, Lipids, 20, 922, 10.1007/BF02534778 · DOI
  54. Murph, 2007, Liquid chromatography mass spectrometry for quantifying plasma lysophospholipids: potential biomarkers for cancer diagnosis, Methods Enzymol., 1, 10.1016/S0076-6879(07)33001-2 · DOI
  55. Lee, 2011, Simultaneous profiling of lysophospholipids and phospholipids from human plasma by nanoflow liquid chromatography-tandem mass spectrometry, Anal. Bioanal. Chem., 400, 2953, 10.1007/s00216-011-4958-7 · doi:10.1007/s00216-011-4958-7
  56. Koistinen, 2015, Quantitative lysophospholipidomics in human plasma and skin by LC–MS/MS, Anal. Bioanal. Chem., 407, 5091, 10.1007/s00216-014-8453-9 · doi:10.1007/s00216-014-8453-9
  57. Okudaira, 2014, Separation and quantification of 2-acyl-1-lysophospholipids and 1-acyl-2-lysophospholipids in biological samples by LC-MS/MS, J. Lipid Res., 55, 2178, 10.1194/jlr.D048439 · DOI · Paper page
  58. Liebisch, 2004, High-throughput quantification of phosphatidylcholine and sphingomyelin by electrospray ionization tandem mass spectrometry coupled with isotope correction algorithm, Biochim. Biophys. Acta − Mol. Cell Biol. Lipids, 1686, 108, 10.1016/j.bbalip.2004.09.003 · DOI · Paper page
  59. Hyötyläinen, 2014, Systems biology strategies to study lipidomes in health and disease, Prog. Lipid Res., 55, 43, 10.1016/j.plipres.2014.06.001 · DOI
  60. Han, 2012, Multi-dimensional mass spectrometry-based shotgun lipidomics and novel strategies for lipidomic analyses, Mass Spectrom. Rev., 31, 134, 10.1002/mas.20342 · DOI · Paper page
  61. Almeida, 2015, Comprehensive lipidome analysis by shotgun lipidomics on a hybrid quadrupole-orbitrap-linear ion trap mass spectrometer, J. Am. Soc. Mass Spectrom., 26, 133, 10.1007/s13361-014-1013-x · DOI
  62. Witting, 2014, Optimizing a ultrahigh pressure liquid chromatography-time of flight-mass spectrometry approach using a novel sub-2μm core–shell particle for in depth lipidomic profiling of Caenorhabditis elegans, J. Chromatogr. A, 1359, 91, 10.1016/j.chroma.2014.07.021 · DOI
  63. Tang, 2004, Charge competition and the linear dynamic range of detection in electrospray ionization mass spectrometry, J. Am. Soc. Mass Spectrom., 15, 1416, 10.1016/j.jasms.2004.04.034 · DOI · Paper page
  64. Zook, 1997, On cluster ions, ion transmission, and linear dynamic range limitations in electrospray (ionspray) mass spectrometry, Int. J. Mass Spectrom. Ion Process., 162, 129, 10.1016/S0168-1176(96)04511-9 · doi:10.1016/s0168-1176(96)04511-9
  65. Cech, 2001, Practical implications of some recent studies in electrospray ionization fundamentals, Mass Spectrom. Rev., 20, 362, 10.1002/mas.10008 · DOI · Paper page
  66. Matuszewski, 2003, Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS, Anal. Chem., 75, 3019, 10.1021/ac020361s · DOI · Paper page
  67. Taylor, 2005, Matrix effects: the Achilles heel of quantitative high-performance liquid chromatography–electrospray–tandem mass spectrometry, Clin. Biochem., 38, 328, 10.1016/j.clinbiochem.2004.11.007 · DOI · Paper page
  68. Trufelli, 2011, An overview of matrix effects in liquid chromatography-mass spectrometry, Mass Spectrom. Rev., 30, 491, 10.1002/mas.20298 · DOI · Paper page
  69. Koivusalo, 2001, Quantitative determination of phospholipid compositions by ESI–MS: effects of acyl chain length, unsaturation, and lipid concentration on instrument response, J. Lipid Res., 42, 663, 10.1016/S0022-2275(20)31176-7 · DOI · Paper page
  70. Khoury, 2016, A study of inter-species ion suppression in electrospray ionization-mass spectrometry of some phospholipid classes, Anal. Bioanal. Chem., 408, 1453, 10.1007/s00216-015-9245-6 · doi:10.1007/s00216-015-9245-6
  71. Hsu, 2000, Charge-remote and charge-driven fragmentation processes in diacyl glycerophosphoethanolamine upon low-energy collisional activation: a mechanistic proposal, J. Am. Soc. Mass Spectrom., 11, 892, 10.1016/S1044-0305(00)00159-8 · DOI

Cited by

See all 107

Metadata

Authors
Triebl, A., Trötzmüller, M., Hartler, J., Stojakovic, T., & Köfeler, H. C.
Venue
Journal of Chromatography B
Publisher
Elsevier BV
Published
2017-05
Volume
1053
Pages
72-80
ISSN
1570-0232 (ISSN-L)
OpenAlex
W2599278944
Cited by
107
References
1
FWCI
5.05
Type
journal article
Language
en
Open access
green
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Funders
Austrian Science Fund (FWF) (P 26148)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.