The effect of particle size on the biodistribution of low-modulus hydrogel PRINT particles
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
There is a growing recognition that the deformability of particles used for drug delivery plays a significant role on their biodistribution and circulation profile. Understanding these effects would provide a crucial tool for the rational design of drug delivery systems. While particles resembling red blood cells (RBCs) in size, shape and deformability have extended circulation times and altered biodistribution profiles compared to rigid, but otherwise similar particles, the in vivo behavior of such highly deformable particles of varied size has not been explored. We report the fabrication of a series of discoid, monodisperse, low-modulus hydrogel particles with diameters ranging from 0.8 to 8.9 μm, spanning sizes smaller than and larger than RBCs. We injected these particles into healthy mice, and tracked their concentration in the blood and their distribution into major organs. These deformable particles all demonstrated some hold up in filtration tissues like the lungs and spleen, followed by release back into the circulation, characterized by decreases in particles in these tissues with concomitant increases in particle concentration in blood. Particles similar to red blood cells in size demonstrated longer circulation times, suggesting that this size and shape of deformable particle is uniquely suited to avoid clearance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanoparticle therapeutics: an emerging treatment modality for cancer
Davis, M. E., Chen, Z., & Shin, D. M. (2008) · Nature Reviews Drug Discovery · doi:10.1038/nrd2614 · Cited by 4,233 · cited 1×
“Conventional wisdom regarding the design of micro- and nanoparticles would predict the smallest particles in this study to be the longest circulating ones [28], as they should be able to more easily avoid physical filtration.”
BackgroundFactors affecting the clearance and biodistribution of polymeric nanoparticles
Alexis, F., Pridgen, E., Molnar, L. K., & Farokhzad, O. C. (2008) · Molecular Pharmaceutics · doi:10.1021/mp800051m · Cited by 3,699 · cited 1×
“Tissues were weighed after imaging, and biodistribution was expressed as a function of fluorescent signal per gram of tissue weight.”
MethodThe effect of particle design on cellular internalization pathways
Gratton, S. E. A., Ropp, P. A., Pohlhaus, P. D., Luft, J. C., Madden, V. J., Napier, M. E., & DeSimone, J. M. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0801763105 · Cited by 2,918 · cited 1×
“An acid containing monomer (2-carboxyethyl acrylate, CEA) was included in the hydrogel monomer mixture at 10% (by weight) to give the particles a negative charge, thereby decreasing non-specific particle uptake [23].”
MethodSelf-citationPhotopolymerizable hydrogels for tissue engineering applications
Nguyen, K. T., & West, J. L. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00175-8 · Cited by 1,669 · cited 2×
“…Napier c, William E. Zamboni d,e,f,g, Joseph M. DeSimone a,e,f,g,h,i, j,k,⁎ a Department of Chemistry, University of North Carolina, United States b Department of Cell and Developmental Biology, University of North Carolina, United States c Department of Biochemistry and Biophysics, University…”
BackgroundPhysical approaches to biomaterial design
Mitragotri, S., & Lahann, J. (2009) · Nature Materials · doi:10.1038/nmat2344 · Cited by 1,445
Use of hydrogel coating to improve the performance of implanted glucose sensors
Yu, B., Wang, C., Ju, Y. M., West, L., Harmon, J., Moussy, Y., & Moussy, F. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.11.010 · Cited by 105 · cited 1×
“their facile control, hydrogels of a range of structures are used in medical applications ranging from drug delivery agents [6,7], to tissue engineering [8] and biosensor coatings [9,10].”
Background
Cited by
Principles of nanoparticle design for overcoming biological barriers to drug delivery
Blanco, E., Shen, H., & Ferrari, M. (2015) · Nature Biotechnology · doi:10.1038/nbt.3330 · Cited by 7,002
Designing hydrogels for controlled drug delivery
Li, J., & Mooney, D. J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.71 · Cited by 4,832
Hydrogel microparticles for biomedical applications
Daly, A. C., Riley, L., Segura, T., & Burdick, J. A. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0148-6 · Cited by 1,249
Anselmo, A. C., Zhang, M., Kumar, S., Vogus, D. R., Menegatti, S., Helgeson, M. E., & Mitragotri, S. (2015) · ACS Nano · doi:10.1021/acsnano.5b00147 · Cited by 643
Stimuli-Responsive Nanomaterials for Biomedical Applications
Blum, A. P., Kammeyer, J. K., Rush, A. M., Callmann, C. E., Hahn, M. E., & Gianneschi, N. C. (2015) · Journal of the American Chemical Society · doi:10.1021/ja510147n · Cited by 540
Metadata
- Authors
- Merkel, T. J., Chen, K., Jones, S. W., Pandya, A. A., Tian, S., Napier, M. E., Zamboni, W. E., & DeSimone, J. M.
- Venue
- Journal of Controlled Release
- Publisher
- Elsevier BV
- Published
- 2012-08
- Volume
- 162
- Issue
- 1
- Pages
- 37-44
- ISSN
- 0168-3659 (ISSN-L)
- OpenAlex
- W2119476922
- Cited by
- 120
- References
- 6
- FWCI
- 3.61
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.