CoChat

Accelerated versus conventional corneal collagen crosslinking

Tomita, Minoru, Mita, Mariko, Huseynova, Tukezban · 2014 · Journal of Cataract and Refractive Surgery
Cited by 234

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

PURPOSE: To compare the outcomes of accelerated corneal collagen crosslinking (CXL) and conventional corneal CXL. SETTINGS: Private practice, Tokyo, Japan. DESIGN: Comparative study. METHODS: Eyes with keratoconus had accelerated CXL (KXL system; 15 minutes riboflavin [Vibex Rapid] presoak; 3 minutes 30 mW/cm(2) ultraviolet-A [UVA] light) or conventional CXL (CCL-365 Vario system; 30 minutes riboflavin [Vibex] presoak; 30 minutes 3 mW/cm(2) UVA light). The postoperative changes in visual acuity, keratometry readings, morphologic changes in the cornea, demarcation line existence, and corneal biomechanical responses with accelerated CXL and conventional CXL were compared. The follow-up was 1 year. RESULTS: The study enrolled 48 eyes of 39 patients; 30 eyes had accelerated CXL, and 18 eyes had conventional CXL. There were no statistically significant differences in postoperative changes in uncorrected or corrected distance visual acuity or in the manifest refraction spherical equivalent between the 2 procedures. There were also no statistically significant differences in the postoperative changes in the keratometric readings from the Pentacam Scheimpflug device or the corneal biomechanical responses from a dynamic bidirectional applanation device (Ocular Response Analyzer) or a dynamic Scheimpflug analyzer (Corvis ST) between the procedures. Similar morphologic changes and a pronounced demarcation line were apparent in eyes in both groups postoperatively. CONCLUSIONS: Accelerated CXL and conventional CXL were both safe and effective. Accelerated CXL, being a fast procedure, appears to be more beneficial for patients and surgeons. FINANCIAL DISCLOSURE(S): No author has a financial or proprietary interest in any material or method mentioned.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jcrs.2013.12.012

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 234

Metadata

Authors
Tomita, M., Mita, M., & Huseynova, T.
Venue
Journal of Cataract and Refractive Surgery
Published
2014-06
Volume
40
Issue
6
Pages
1013-1020
ISSN
  • 0146-2776 (ISSN-L)
  • 0886-3350
OpenAlex
W2140648982
Cited by
234
References
13
FWCI
24.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accelerated versus conventional corneal collagen crosslinking. https://app.cochat.ai/papers/10.1016/j.jcrs.2013.12.012
The paper
Tomita, M., Mita, M., & Huseynova, T. (2014). Accelerated versus conventional corneal collagen crosslinking. Journal of Cataract and Refractive Surgery. https://doi.org/10.1016/j.jcrs.2013.12.012

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.