A machine learning approach for prioritizing groundwater testing for per-and polyfluoroalkyl substances (PFAS)
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Regulatory agencies are beginning to recognize and regulate per-and polyfluoroalkyl substances (PFAS) as concerning environmental contaminants. In groundwater management, testing and mitigation strategies are desirable, but can be time and cost-intensive processes. As a result, only a fraction of all groundwater wells has been tested for PFAS levels, resulting in potentially extended drinking water exposure to PFAS in the meantime. In this study, we build a series of machine learning models (including linear and random forest regressors) to predict PFAS based on a groundwater dataset from California. These models are used to compare the relative predictive ability of co-contaminant fingerprints, hydrological properties, soil parameters, proximity of airports/military bases, and geospatial data. Additionally, a random forest machine learning model that combines all data types can quantitatively predict the maximum PFAS compound concentration in a well with a Spearman correlation of 0.64 and can discern wells containing concerningly high concentrations of PFAS with an accuracy of 91 % (AUC of 0.90). This approach may have widespread utility for other hazardous anthropogenic compounds in groundwater. Future investigations should evaluate the practicability of using machine learning to prospectively prioritize contaminant testing in groundwater wells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global Distribution of Perfluorooctane Sulfonate in Wildlife
Giesy, J. P., & Kannan, K. (2001) · Environmental Science & Technology · doi:10.1021/es001834k · Cited by 2,750
Hu, X. C., Andrews, D. Q., Lindstrom, A. B., Bruton, T. A., Schaider, L. A., Grandjean, P., Lohmann, R., Carignan, C. C., Blum, A., Balan, S. A., et al. (2016) · Environmental Science & Technology Letters · doi:10.1021/acs.estlett.6b00260 · Cited by 1,333
Conder, J. M., Hoke, R. A., Wolf, W. D., Russell, M. H., & Buck, R. C. (2008) · Environmental Science & Technology · doi:10.1021/es070895g · Cited by 1,206
Perfluorooctanesulfonate and related fluorochemicals in human blood from several countries
Kannan, K., Corsolini, S., Falandysz, J., Fillmann, G., Kumar, K. S., Loganathan, B. G., Mohd, M. A., Olivero, J., Wouwe, N. V., Yang, J. H., et al. (2004) · Environmental Science & Technology · doi:10.1021/es0493446 · Cited by 1,056
Persistence of Perfluoroalkyl Acid Precursors in AFFF-Impacted Groundwater and Soil
Houtz, E. F., Higgins, C. P., Field, J. A., & Sedlak, D. L. (2013) · Environmental Science & Technology · doi:10.1021/es4018877 · Cited by 849
Oxidative Conversion as a Means of Detecting Precursors to Perfluoroalkyl Acids in Urban Runoff
Houtz, E. F., & Sedlak, D. L. (2012) · Environmental Science & Technology · doi:10.1021/es302274g · Cited by 681
Crone, B. C., Speth, T. F., Wahman, D. G., Smith, S. J., Abulikemu, G., Kleiner, E. J., & Pressman, J. G. (2019) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2019.1614848 · Cited by 408
Biodegradation of Perfluorinated Compounds
Parsons, J. R., Sáez, M., Dolfing, J., & de Voogt, P. (2008) · Reviews of Environmental Contamination and Toxicology · doi:10.1007/978-0-387-78444-1_2 · Cited by 258
Wang, Z., Boucher, J. M., Scheringer, M., Cousins, I. T., & Hungerbühler, K. (2017) · Environmental Science & Technology · doi:10.1021/acs.est.6b06191 · Cited by 159
Houtz, E., Wang, M., & Park, J.-S. (2018) · Environmental Science & Technology · doi:10.1021/acs.est.8b04028 · Cited by 145
Cited by
McMahon, P. B., Tokranov, A. K., Bexfield, L. M., Lindsey, B. D., Johnson, T. D., Lombard, M. A., & Watson, E. (2022) · Environmental Science & Technology · doi:10.1021/acs.est.1c04795 · Cited by 183
Perfluoroalkyl/polyfluoroalkyl substances: Links to cardiovascular disease risk
Schlezinger, J. J., & Gokce, N. (2024) · Circulation Research · doi:10.1161/circresaha.124.323697 · Cited by 103
Dawson, D. E., Lau, C., Pradeep, P., Sayre, R. R., Judson, R. S., Tornero-Velez, R., & Wambaugh, J. F. (2023) · Toxics · doi:10.3390/toxics11020098 · Cited by 56
Large-scale assessment of PFAS compounds in drinking water sources using machine learning
Fernandez, N., Nejadhashemi, A. P., & Loveall, C. (2023) · Water Research · doi:10.1016/j.watres.2023.120307 · Cited by 32
Machine Learning Models for PFAS Tracking, Detection and Remediation: A Review
Andraju, N., Curtzwiler, G., Ji, Y., Kozliak, E., & Ranganathan, P. (2023) · 2023 IEEE International Conference on Electro Information Technology (eIT) · doi:10.1109/eit57321.2023.10187291 · Cited by 4
Metadata
- Authors
- George, S., & Dixit, A.
- Venue
- Journal of Environmental Management
- Publisher
- Elsevier BV
- Published
- 2021-10
- Volume
- 295
- Pages
- 113359
- ISSN
- 0301-4797 (ISSN-L)
- OpenAlex
- W3095129627
- Cited by
- 60
- References
- 11
- FWCI
- 2.50
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A machine learning approach for prioritizing groundwater testing for per-and polyfluoroalkyl substances (PFAS). https://app.cochat.ai/papers/10.1016/j.jenvman.2021.113359
- The paper
- George, S., & Dixit, A. (2021). A machine learning approach for prioritizing groundwater testing for per-and polyfluoroalkyl substances (PFAS). Journal of Environmental Management. https://doi.org/10.1016/j.jenvman.2021.113359
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.