Roles of sunlight and natural ventilation for controlling infection: historical and current perspectives
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Background Infections caught in buildings are a major global cause of sickness and mortality. Understanding how infections spread is pivotal to public health yet current knowledge of indoor transmission remains poor. Aim To review the roles of natural ventilation and sunlight for controlling infection within healthcare environments. Methods Comprehensive literature search was performed, using electronic and library databases to retrieve English language papers combining infection; risk; pathogen; and mention of ventilation; fresh air; and sunlight. Foreign language articles with English translation were included, with no limit imposed on publication date. Findings In the past, hospitals were designed with south-facing glazing, cross-ventilation and high ceilings because fresh air and sunlight were thought to reduce infection risk. Historical and recent studies suggest that natural ventilation offers protection from transmission of airborne pathogens. Particle size, dispersal characteristics and transmission risk require more work to justify infection control practices concerning airborne pathogens. Sunlight boosts resistance to infection, with older studies suggesting potential roles for surface decontamination. Conclusions Current knowledge of indoor transmission of pathogens is inadequate, partly due to lack of agreed definitions for particle types and mechanisms of spread. There is recent evidence to support historical data on the effects of natural ventilation but virtually none for sunlight. Modern practice of designing healthcare buildings for comfort favours pathogen persistence. As the number of effective antimicrobial agents declines, further work is required to clarify absolute risks from airborne pathogens along with any potential benefits from additional fresh air and sunlight.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guideline for hand hygiene in health-care settings
Boyce, J. M., & Pittet, D. (2002) · American Journal of Infection Control · doi:10.1067/mic.2002.130391 · Cited by 2,120
Riemersma-van der Lek, R. F. (2008) · JAMA · doi:10.1001/jama.299.22.2642 · Cited by 803 · cited 1×
“Bright light also has benefits beyond relieving the symptoms of depression, since increasing light levels slows down the rate of cognitive decline in dementia patients.(170) Without proper time-cues from the sun, or other sources, underlying body rhythms may become disturbed to cause a range of health problems, includ…”
BackgroundThe role of particle size in aerosolised pathogen transmission: a review
Gralton, J., Tovey, E., McLaws, M.-L., & Rawlinson, W. D. (2011) · Journal of Infection · doi:10.1016/j.jinf.2010.11.010 · Cited by 665
On the history of indoor air quality and health
Sundell, J. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00273.x · Cited by 613 · cited 1×
“According to one estimate, more than half of the body’s intake of air during a lifetime is inhaled indoors.(137) New homes in Britain and other countries make increasing use of mechanical ventilation.”
BackgroundInfluenza Virus in Human Exhaled Breath: An Observational Study
Fabian, P., McDevitt, J. J., DeHaan, W. H., Fung, R. O. P., Cowling, B. J., Chan, K. H., Leung, G. M., & Milton, D. K. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002691 · Cited by 496 · cited 1×
“Despite more than a century of infection study, detailed specifications needed to prevent airborne dispersal of pathogens are still unknown, with ongoing controversy over the importance of airborne spread for certain pathogens.(8,187,188) There is lack of consensus on particle size, transmission characteristics and as…”
BackgroundNatural Ventilation for the Prevention of Airborne Contagion
Escombe, A. R., Oeser, C. C., Gilman, R. H., Navincopa, M., Ticona, E., Pan, W., Martínez, C., Chacaltana, J., Rodríguez, R., Moore, D. A. J., et al. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040068 · Cited by 420 · cited 3×
“By contrast, clinical rooms with high ceilings and multiple large windows in pre-1950 hospitals gave the greatest protection, even if the windows were only partially open.(123) Naturally ventilated wards can achieve higher air change rates than those with mechanical systems.”
BackgroundInfluentialWhich preventive measures might protect health care workers from SARS?
Chen, W.-Q., Ling, W.-H., Lu, C.-Y., Hao, Y.-T., Lin, Z.-N., Ling, L., Huang, J., Li, G., & Yan, G.-M. (2009) · BMC Public Health · doi:10.1186/1471-2458-9-81 · Cited by 113
The dynamics of norovirus outbreak epidemics: Recent insights
Marshall, J. A., & Bruggink, L. D. (2011) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph8041141 · Cited by 88 · cited 1×
“This virus is easily transmitted between individuals, via contact with contaminated surfaces, food, and/or through aerosol spread.(68) A recent review of hospital outbreaks concluded that 18.”
Background
Cited by
Dancer, S. J. (2014) · Clinical Microbiology Reviews · doi:10.1128/cmr.00020-14 · Cited by 679
Self-citationTang, J. W., Bahnfleth, W. P., Bluyssen, P. M., Buonanno, G., Jimenez, J. L., Kurnitski, J., Li, Y., Miller, S., Sekhar, C., Morawska, L., et al. (2021) · Journal of Hospital Infection · doi:10.1016/j.jhin.2020.12.022 · Cited by 350
“Some of the explanations and rationale for SARS-CoV-2 transmission can be applied to other respiratory viruses, but these should consider the numbers and types of studies available for those specific viruses [72,73].”
Self-citationMaclean, M., McKenzie, K., Anderson, J. G., Gettinby, G., & MacGregor, S. J. (2014) · Journal of Hospital Infection · doi:10.1016/j.jhin.2014.06.004 · Cited by 167
Relative humidity in droplet and airborne transmission of disease
Božič, A., & Kanduč, M. (2021) · Journal of Biological Physics · doi:10.1007/s10867-020-09562-5 · Cited by 142
Metadata
- Authors
- Hobday, R. A., & Dancer, S. J.
- Venue
- Journal of Hospital Infection
- Publisher
- Elsevier BV
- Published
- 2013-08
- Volume
- 84
- Issue
- 4
- Pages
- 271-282
- ISSN
- 0195-6701 (ISSN-L)
- OpenAlex
- W1993804134
- Cited by
- 175
- References
- 8
- FWCI
- 5.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Roles of sunlight and natural ventilation for controlling infection: historical and current perspectives. https://app.cochat.ai/papers/10.1016/j.jhin.2013.04.011
- The paper
- Hobday, R. A., & Dancer, S. J. (2013). Roles of sunlight and natural ventilation for controlling infection: historical and current perspectives. Journal of Hospital Infection. https://doi.org/10.1016/j.jhin.2013.04.011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.