Antibacterial surface design of biomedical titanium materials for orthopedic applications

Yuan, Zhang, He, Ye, Lin, Chuanchuan, Liu, Peng, Cai, Kaiyong · 2021 · Journal of Materials Science & Technology

Abstract

Abstract Titanium (Ti) and titanium alloys have become widely used as biomedical materials in orthopedics because of their good machinability, corrosion resistance, low elastic modulus and excellent biocompatibility. However, when Ti-based implants are used for bone repair and replacement, they are easy to cause bacteria adhesion and aggregation, which leads to postoperative infection. In addition, Ti and its alloys, as bio-inert materials, cannot induce desirable tissue responses such as osseointegration after implantation, which will eventually lead to implant loosening. Postoperative bacterial infection and lack of osseointegration directly lead to the failure of implantation surgery and are not conductive to the long-term service of titanium-based implants. Recently, researchers have made many attempts to focus on the surface modification of multifunctional Ti-based implants to endow them with both antibacterial activity and simultaneous osteoinductive property. In this review, we primarily highlighted the recent progresses in the surface design of Ti implants with both antimicrobial and osteoinductive properties for orthopedic applications. First, the challenges for treating implant-associated infections were briefly introduced such as the emergence of antibiotic resistance, the formation of biofilms, and the construction of cell-selective surfaces. Some of the essential fundamentals were concisely introduced to address these emerging challenges. Next, we intended to elaborate the potential strategies of multifunctional surface design to endow good osseointegration for antibacterial Ti implants and highlighted the recent advances of the implants. We hope that this review will provide theoretical basis and technical support for the development of new Ti implant with antibacterial and osteogenic functions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jmst.2020.10.066

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 165

Metadata

Authors
Yuan, Z., He, Y., Lin, C., Liu, P., & Cai, K.
Venue
Journal of Materials Science & Technology
Publisher
Elsevier BV
Published
2021-07
Volume
78
Pages
51-67
ISSN
1005-0302 (ISSN-L)
OpenAlex
W3109482165
Cited by
165
References
12
FWCI
6.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Antibacterial surface design of biomedical titanium materials for orthopedic applications. https://app.cochat.ai/papers/10.1016/j.jmst.2020.10.066
The paper
Yuan, Z., He, Y., Lin, C., Liu, P., & Cai, K. (2021). Antibacterial surface design of biomedical titanium materials for orthopedic applications. Journal of Materials Science & Technology. https://doi.org/10.1016/j.jmst.2020.10.066

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.