CoChat

Comprehensive chronic laminar single-unit, multi-unit, and local field potential recording performance with planar single shank electrode arrays

Open access
Kozai, Takashi D.Y., Du, Zhanhong, Gugel, Zhannetta V., Smith, Matthew A., Chase, Steven M., Bodily, Lance M., Caparosa, Ellen M., Friedlander, Robert M., Cui, X. Tracy · 2015 · Journal of Neuroscience Methods
Cited by 138

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

Abstract

Background Intracortical electrode arrays that can record extracellular action potentials from small, targeted groups of neurons are critical for basic neuroscience research and emerging clinical applications. In general, these electrode devices suffer from reliability and variability issues, which have led to comparative studies of existing and emerging electrode designs to optimize performance. Comparisons of different chronic recording devices have been limited to single-unit (SU) activity and employed a bulk averaging approach treating brain architecture as homogeneous with respect to electrode distribution. New Method In this study, we optimize the methods and parameters to quantify evoked multi-unit (MU) and local field potential (LFP) recordings in 8 mice visual cortices. Results These findings quantify the large recording differences stemming from anatomical differences in depth and the layer dependent relative changes to SU and MU recording performance over 6-months. For example, performance metrics in Layer V and stratum pyramidale were initially higher than Layer II/III, but decrease more rapidly. On the other hand, Layer II/III maintained recording metrics longer. In addition, chronic changes at the level of layer IV are evaluated using visually evoked current source density. Comparison with Existing Method(s) The use of MU and LFP activity for evaluation and tracking biological depth provides a more comprehensive characterization of the electrophysiological performance landscape of microelectrodes. Conclusions A more extensive spatial and temporal insight into the chronic electrophysiological performance over time will help uncover the biological and mechanical failure mechanisms of the neural electrodes and direct future research toward the elucidation of design optimization for specific applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jneumeth.2014.12.010

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 42 references

Research works printed but not linked: 70

  1. Antolik, 2011, Development of maps of simple and complex cells in the primary visual cortex, Front Comput Neurosci, 5, 17, 10.3389/fncom.2011.00017 · DOI
  2. Azemi, 2010, Seeding neural progenitor cells on silicon-based neural probes, J Neurosurg, 113, 673, 10.3171/2010.1.JNS09313 · DOI · Paper page
  3. Bair, 2002, The timing of response onset and offset in macaque visual neurons, J Neurosci, 22, 3189, 10.1523/JNEUROSCI.22-08-03189.2002 · DOI · Paper page
  4. Bjornsson, 2006, Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion, J Neural Eng, 3, 196, 10.1088/1741-2560/3/3/002 · DOI · Paper page
  5. Bokil, 2010, Chronux: a platform for analyzing neural signals, J Neurosci Methods, 192, 146, 10.1016/j.jneumeth.2010.06.020 · DOI · Paper page
  6. Boutin, 2001, Role of IL-1alpha and IL-1beta in ischemic brain damage, J Neurosci, 21, 5528, 10.1523/JNEUROSCI.21-15-05528.2001 · DOI · Paper page
  7. Brainard, 1997, The psychophysics toolbox, Spat Vis, 10, 433, 10.1163/156856897X00357 · DOI · Paper page
  8. Brodie, 1978, The response of the Limulus retina to moving stimuli: a prediction by Fourier synthesis, J Gen Physiol, 72, 129, 10.1085/jgp.72.2.129 · doi:10.1085/jgp.72.2.129
  9. Burns, 2010, Comparisons of the dynamics of local field potential and multiunit activity signals in macaque visual cortex, J Neurosci, 30, 13739, 10.1523/JNEUROSCI.0743-10.2010 · DOI · Paper page
  10. Chase, 2012, Behavioral and neural correlates of visuomotor adaptation observed through a brain–computer interface in primary motor cortex, J Neurophysiol, 108, 624, 10.1152/jn.00371.2011 · DOI · Paper page
  11. Chase, 2009, Bias, optimal linear estimation, and the differences between open-loop simulation and closed-loop performance of spiking-based brain–computer interface algorithms, Neural Netw, 22, 1203, 10.1016/j.neunet.2009.05.005 · DOI · Paper page
  12. Chen, 2014, Binocular input coincidence mediates critical period plasticity in the mouse primary visual cortex, J Neurosci, 34, 2940, 10.1523/JNEUROSCI.2640-13.2014 · DOI
  13. Chestek, 2011, Long-term stability of neural prosthetic control signals from silicon cortical arrays in rhesus macaque motor cortex, J Neural Eng, 8, 045005, 10.1088/1741-2560/8/4/045005 · DOI · Paper page
  14. Cornelissen, 2002, The eyelink toolbox: eye tracking with MATLAB and the psychophysics toolbox, Behav Res Methods Instrum Comput, 34, 613, 10.3758/BF03195489 · DOI · Paper page
  15. Cui, 2001, Electrochemical deposition and characterization of conducting polymer polypyrrole/PSS on multichannel neural probes, Sens Actuators A Phys, 93, 8, 10.1016/S0924-4247(01)00637-9 · DOI · Paper page
  16. Cui, 2003, Electrochemical deposition and characterization of poly (3,4-ethylenedioxythiophene) on neural microelectrode arrays, Sens Actuators B Chem, 89, 92, 10.1016/S0925-4005(02)00448-3 · DOI · Paper page
  17. Dai, 2012, Representation of surface luminance and contrast in primary visual cortex, Cereb Cortex, 22, 776, 10.1093/cercor/bhr133 · DOI
  18. Fee, 1996, Automatic sorting of multiple unit neuronal signals in the presence of anisotropic and non-Gaussian variability, J Neurosci Methods, 69, 175, 10.1016/S0165-0270(96)00050-7 · DOI · Paper page
  19. Flint, 2013, Long term, stable brain machine interface performance using local field potentials and multiunit spikes, J Neural Eng, 10, 056005, 10.1088/1741-2560/10/5/056005 · DOI · Paper page
  20. Foster, 1985, Spatial and temporal frequency selectivity of neurones in visual cortical areas V1 and V2 of the macaque monkey, J Physiol, 365, 331, 10.1113/jphysiol.1985.sp015776 · DOI · Paper page
  21. Fraser, 2009, Control of a brain–computer interface without spike sorting, J Neural Eng, 6, 055004, 10.1088/1741-2560/6/5/055004 · DOI · Paper page
  22. Fraser, 2012, Recording from the same neurons chronically in motor cortex, J Neurophysiol, 107, 1970, 10.1152/jn.01012.2010 · DOI · Paper page
  23. Gage, 2010, Selective activation of striatal fast-spiking interneurons during choice execution, Neuron, 67, 466, 10.1016/j.neuron.2010.06.034 · DOI · Paper page
  24. Gao, 2010, Parallel input channels to mouse primary visual cortex, J Neurosci, 30, 5912, 10.1523/JNEUROSCI.6456-09.2010 · DOI · Paper page
  25. Haider, 2013, Inhibition dominates sensory responses in the awake cortex, Nature, 493, 97, 10.1038/nature11665 · DOI · Paper page
  26. Harding, 1999, Two visual mechanisms of photosensitivity, Epilepsia, 40, 1446, 10.1111/j.1528-1157.1999.tb02018.x · DOI
  27. Harris, 2011, Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodies, J Neural Eng, 8, 066011, 10.1088/1741-2560/8/6/066011 · DOI · Paper page
  28. Harris, 2010, Does neural input or processing play a greater role in the magnitude of neuroimaging signals?, Front Neuroenerg, 2
  29. Jeyabalaratnam, 2013, Adaptation shifts preferred orientation of tuning curve in the mouse visual cortex, PLoS ONE, 8, e64294, 10.1371/journal.pone.0064294 · DOI
  30. Jia, 2011, Stimulus selectivity and spatial coherence of gamma components of the local field potential, J Neurosci, 31, 9390, 10.1523/JNEUROSCI.0645-11.2011 · DOI · Paper page
  31. Jin, 2011, Population receptive fields of ON and OFF thalamic inputs to an orientation column in visual cortex, Nat Neurosci, 14, 232, 10.1038/nn.2729 · DOI · Paper page
  32. Johnson, 2007, Spatiotemporal pH dynamics following insertion of neural microelectrode arrays, J Neurosci Methods, 160, 276, 10.1016/j.jneumeth.2006.09.023 · DOI
  33. Kipke, 2008, Advanced neurotechnologies for chronic neural interfaces: new horizons and clinical opportunities, J Neurosci, 28, 11830, 10.1523/JNEUROSCI.3879-08.2008 · DOI · Paper page
  34. Kleiner, 2007, What's new in psychtoolbox-3?, Perception, 36
  35. Kozai, 2015, Mechanical failure modes of chronically implanted planar silicon-based neural probes for laminar recording, Biomaterials, 37, 25, 10.1016/j.biomaterials.2014.10.040 · DOI · Paper page
  36. Kozai, 2009, Insertion shuttle with carboxyl terminated self-assembled monolayer coatings for implanting flexible polymer neural probes in the brain, J Neurosci Methods, 184, 199, 10.1016/j.jneumeth.2009.08.002 · DOI · Paper page
  37. Kozai, 2010, Reduction of neurovascular damage resulting from microelectrode insertion into the cerebral cortex using in vivo two-photon mapping, J Neural Eng, 7, 046011, 10.1088/1741-2560/7/4/046011 · DOI · Paper page
  38. Kuhlman, 2011, Fast-spiking interneurons have an initial orientation bias that is lost with vision, Nat Neurosci, 14, 1121, 10.1038/nn.2890 · DOI · Paper page
  39. Land, 2013, Response properties of local field potentials and multiunit activity in the mouse visual cortex, Neuroscience, 10.1016/j.neuroscience.2013.08.065 · DOI
  40. Land, 2013, Response properties of local field potentials and multiunit activity in the mouse visual cortex, Neuroscience, 254, 141, 10.1016/j.neuroscience.2013.08.065 · DOI
  41. Lennie, 1981, The physiological basis of variations in visual latency, Vis Res, 21, 815, 10.1016/0042-6989(81)90180-2 · DOI
  42. Ludwig, 2009, Using a common average reference to improve cortical neuron recordings from microelectrode arrays, J Neurophysiol, 101, 1679, 10.1152/jn.90989.2008 · DOI · Paper page
  43. Luo, 2011, Carbon nanotube nanoreservior for controlled release of anti-inflammatory dexamethasone, Biomaterials, 32, 6316, 10.1016/j.biomaterials.2011.05.020 · DOI · Paper page
  44. Marshall, 1943, Cortical response of the anesthetized cat to gross photic and electrical afferent stimulation, J Neurophysiol, 6, 1, 10.1152/jn.1943.6.1.1 · DOI · Paper page
  45. Mitzdorf, 1978, Prominent excitatory pathways in the cat visual cortex (A 17 and A 18): a current source density analysis of electrically evoked potentials, Exp Brain Res, 33, 371, 10.1007/BF00235560 · DOI · Paper page
  46. Mukamel, 2014, A transition in brain state during propofol-induced unconsciousness, J Neurosci, 34, 839, 10.1523/JNEUROSCI.5813-12.2014 · DOI · Paper page
  47. Pelli, 1997, The videotoolbox software for visual psychophysics: transforming numbers into movies, Spat Vis, 10, 437, 10.1163/156856897X00366 · DOI · Paper page
  48. Perel, 2013, Direction and speed tuning of motor-cortex multi-unit activity and local field potentials during reaching movements, Conf Proc IEEE Eng Med Biol Soc, 2013, 299
  49. Peters, 1985, The neuronal composition of area 17 of rat visual cortex III. Numerical considerations, J Comp Neurol, 238, 263, 10.1002/cne.902380303 · DOI · Paper page
  50. Potter, 2012, Stab injury and device implantation within the brain results in inversely multiphasic neuroinflammatory and neurodegenerative responses, J Neural Eng, 9, 046020, 10.1088/1741-2560/9/4/046020 · DOI · Paper page
  51. Richardson, 2012, Activity of the same motor cortex neurons during repeated experience with perturbed movement dynamics, J Neurophysiol, 107, 3144, 10.1152/jn.00477.2011 · DOI
  52. Sakatani, 2004, PC-based high-speed video-oculography for measuring rapid eye movements in mice, Neurosci Res, 49, 123, 10.1016/j.neures.2004.02.002 · DOI
  53. Sawyer, 2013, Nanoparticle-based evaluation of blood-brain barrier leakage during the foreign body response, J Neural Eng, 10, 016013, 10.1088/1741-2560/10/1/016013 · DOI
  54. Saxena, 2013, The impact of chronic blood–brain barrier breach on intracortical electrode function, Biomaterials, 34, 4703, 10.1016/j.biomaterials.2013.03.007 · DOI · Paper page
  55. Scott, 2012, Wandering neuronal migration in the postnatal vertebrate forebrain, J Neurosci, 32, 1436, 10.1523/JNEUROSCI.2145-11.2012 · DOI
  56. Sellers, 2013, Anesthesia differentially modulates spontaneous network dynamics by cortical area and layer, J Neurophysiol, 110, 2739, 10.1152/jn.00404.2013 · DOI · Paper page
  57. Shoham, 2006, How silent is the brain: is there a dark matter problem in neuroscience, J Comp Physiol A, 192, 777, 10.1007/s00359-006-0117-6 · DOI · Paper page
  58. Stensaas, 1976, The reaction of the cerebral cortex to chronically implanted plastic needles, Acta Neuropathol, 35, 187
  59. Stoelzel, 2009, Stability of thalamocortical synaptic transmission across awake brain states, J Neurosci, 29, 6851, 10.1523/JNEUROSCI.5983-08.2009 · DOI · Paper page
  60. Stoetzner, 2010, State-dependent plasticity of the corticostriatal pathway, Neuroscience, 165, 1013, 10.1016/j.neuroscience.2009.11.031 · DOI
  61. Tyler, 1998, Anatomical comparison of the macaque and marsupial visual cortex: common features that may reflect retention of essential cortical elements, J Comp Neurol, 400, 449, 10.1002/(SICI)1096-9861(19981102)400:4<449::AID-CNE2>3.0.CO;2-A · DOI · Paper page
  62. Vazquez, 2013, Neural and hemodynamic responses elicited by forelimb- and photo-stimulation in channelrhodopsin-2 mice: insights into the hemodynamic point spread function, Cereb Cortex
  63. Vogels, 1994, Activity of inferior temporal neurons during orientation discrimination with successively presented gratings, J Neurophysiol, 71, 1428, 10.1152/jn.1994.71.4.1428 · DOI · Paper page
  64. Ward, 2009, Toward a comparison of microelectrodes for acute and chronic recordings, Brain Res, 1282, 183, 10.1016/j.brainres.2009.05.052 · DOI · Paper page
  65. Williams, 1999, Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex, Brain Res Brain Res Protoc, 4, 303, 10.1016/S1385-299X(99)00034-3 · DOI · Paper page
  66. Woolley, 2013, Chronic intracortical microelectrode arrays induce non-uniform, depth-related tissue responses, J Neural Eng, 10, 026007, 10.1088/1741-2560/10/2/026007 · DOI · Paper page
  67. Xu, 2007, Choice of cranial window type for in vivo imaging affects dendritic spine turnover in the cortex, Nat Neurosci, 10, 549, 10.1038/nn1883 · DOI · Paper page
  68. Yamasaki, 1995, Interleukin-1 as a pathogenetic mediator of ischemic brain damage in rats, Stroke, 26, 676, 10.1161/01.STR.26.4.676 · DOI · Paper page
  69. Yazdan-Shahmorad, 2011, Estimation of electrode location in a rat motor cortex by laminar analysis of electrophysiology and intracortical electrical stimulation, J Neural Eng, 8, 046018, 10.1088/1741-2560/8/4/046018 · DOI
  70. Zhong, 2005, Controlled release of anti-inflammatory agent [alpha]-MSH from neural implants, J Control Release, 106, 309, 10.1016/j.jconrel.2005.05.012 · DOI

Cited by

Metadata

Authors
Kozai, T. D. Y., Du, Z., Gugel, Z. V., Smith, M. A., Chase, S. M., Bodily, L. M., Caparosa, E. M., Friedlander, R. M., & Cui, X. T.
Venue
Journal of Neuroscience Methods
Publisher
Elsevier BV
Published
2015-03
Volume
242
Pages
15-40
ISSN
0165-0270 (ISSN-L)
OpenAlex
W1971567789
Cited by
138
References
42
FWCI
3.62
Type
journal article
Language
en
Open access
bronze
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Funders
  • NIH (5R01NS062019-03, R01 EY022928)
  • Pittsburgh Foundation
  • NIH/NINDS (5R01NS039324-15, 5R01NS07748-04)
  • David Scaife Family Foundation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.