CO2 electroreduction to multicarbon products from carbonate capture liquid
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Alkali hydroxide systems capture CO 2 as carbonate; however, generating a pure CO 2 stream requires significant energy input, typically from thermal cycling to 900°C. What is more, the subsequent valorization of gas-phase CO 2 into products presents additional energy requirements and system complexities, including managing the formation of (bi)carbonate in an electrolyte and separating unreacted CO 2 downstream. Here, we report the direct electrochemical conversion of CO 2 , captured in the form of carbonate, into multicarbon (C 2+ ) products. Using an interposer and a Cu/CoPc-CNTs electrocatalyst, we achieve 47% C 2+ Faradaic efficiency at 300 mA cm −2 and a full cell voltage of 4.1 V. We report 56 wt % of C 2 H 4 and no detectable C 1 gas in the product gas stream: CO, CH 4 , and CO 2 combined total below 0.9 wt % (0.1 vol %). This approach obviates the need for energy to regenerate lost CO 2 , an issue seen in prior CO 2 -to-C 2+ reports.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CO 2 electroreduction to ethylene via hydroxide-mediated copper catalysis at an abrupt interface
Dinh, C.-T., Burdyny, T., Kibria, M. G., Seifitokaldani, A., Gabardo, C. M., García de Arquer, F. P., Kiani, A., Edwards, J. P., De Luna, P., Bushuyev, O. S., et al. (2018) · Science · doi:10.1126/science.aas9100 · Cited by 2,515
Self-citationA Process for Capturing CO2 from the Atmosphere
Keith, D. W., Holmes, G., St. Angelo, D., & Heidel, K. (2018) · Joule · doi:10.1016/j.joule.2018.05.006 · Cited by 1,910 · cited 1×
“Since CO 2 separation is an energy-intensive process (2–4.4 GJ/tonne of CO 2 ), 16,26,27 unreacted CO 2 significantlyincreases overall system energy requirements.”
BackgroundInfluentialGeneral Techno-Economic Analysis of CO 2 Electrolysis Systems
Jouny, M., Luc, W., & Jiao, F. (2018) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.7b03514 · Cited by 1,628 · cited 1×
“For the spacing range of 130–270 mm, optimal conditions, including [CO2(g)] > 4 vol % and the desired local pH, were achieved at the current density range 250–350 mA cm (2), a regime of applied interest.(33,34) In the case wherein the amount of carbonate is limited due to a small spacing, such as <130 mm, there is no…”
CO 2 electrolysis to multicarbon products at activities greater than 1 A cm −2
García de Arquer, F. P., Dinh, C.-T., Ozden, A., Wicks, J., McCallum, C., Kirmani, A. R., Nam, D.-H., Gabardo, C., Seifitokaldani, A., Wang, X., et al. (2020) · Science · doi:10.1126/science.aay4217 · Cited by 1,517
Self-citationCO 2 electrolysis to multicarbon products in strong acid
Huang, J. E., Li, F., Ozden, A., Sedighian Rasouli, A., García de Arquer, F. P., Liu, S., Zhang, S., Luo, M., Wang, X., Lum, Y., et al. (2021) · Science · doi:10.1126/science.abg6582 · Cited by 1,359
Self-citationMolecular tuning of CO2-to-ethylene conversion
Li, F., Thevenon, A., Rosas-Hernández, A., Wang, Z., Li, Y., Gabardo, C. M., Ozden, A., Dinh, C. T., Li, J., Wang, Y., et al. (2020) · Nature · doi:10.1038/s41586-019-1782-2 · Cited by 1,275
Self-citationTechno-economic assessment of low-temperature carbon dioxide electrolysis
Shin, H., Hansen, K. U., & Jiao, F. (2021) · Nature Sustainability · doi:10.1038/s41893-021-00739-x · Cited by 741 · cited 1×
“33,34 In the case wherein the amount of carbonate is limited due to a small spacing, such as 130 m m, there is no increase in the in situ CO 2 (g) concentration at higher current densities (Figure S3).”
BackgroundLi, F., Li, Y. C., Wang, Z., Li, J., Nam, D.-H., Lum, Y., Luo, M., Wang, X., Ozden, A., Hung, S.-F., et al. (2019) · Nature Catalysis · doi:10.1038/s41929-019-0383-7 · Cited by 711
Self-citationThe future of low-temperature carbon dioxide electrolysis depends on solving one basic problem
Rabinowitz, J. A., & Kanan, M. W. (2020) · Nature Communications · doi:10.1038/s41467-020-19135-8 · Cited by 658 · cited 3×
“19,20 Enticingly, recent studies have overcome this CO 2 utilization limit via local CO 2 regeneration 21–23 ; however, until now, the product gas stream has still been diluted by unreacted CO 2 and gas-phase CO 2 -derived products such as carbon monoxide and methane.”
BackgroundClimate change mitigation potential of carbon capture and utilization in the chemical industry
Kätelhön, A., Meys, R., Deutz, S., Suh, S., & Bardow, A. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1821029116 · Cited by 643
Zhang, X., Wang, Y., Gu, M., Wang, M., Zhang, Z., Pan, W., Jiang, Z., Zheng, H., Lucero, M., Wang, H., et al. (2020) · Nature Energy · doi:10.1038/s41560-020-0667-9 · Cited by 631 · cited 1×
“35,36 We fabricated the layer-by-layer catalyst via airbrushing.”
MethodGabardo, C. M., O’Brien, C. P., Edwards, J. P., McCallum, C., Xu, Y., Dinh, C.-T., Li, J., Sargent, E. H., & Sinton, D. (2019) · Joule · doi:10.1016/j.joule.2019.07.021 · Cited by 611 · cited 1×
“19,20 Enticingly, recent studies have overcome this CO2 utilization limit via local CO2 regeneration ; however, until now, the product gas stream has still been diluted by unreacted CO2 and gas-phase CO2-derived products such as carbon monoxide and methane.(22,24,25) Even in systems that achieved >76% CO2 utilization…”
BackgroundSelf-citationVarela, A. S., Kroschel, M., Reier, T., & Strasser, P. (2016) · Catalysis Today · doi:10.1016/j.cattod.2015.06.009 · Cited by 542
Kim, C., Bui, J. C., Luo, X., Cooper, J. K., Kusoglu, A., Weber, A. Z., & Bell, A. T. (2021) · Nature Energy · doi:10.1038/s41560-021-00920-8 · Cited by 473 · cited 1×
“19,20 Enticingly, recent studies have overcome this CO2 utilization limit via local CO2 regeneration ; however, until now, the product gas stream has still been diluted by unreacted CO2 and gas-phase CO2-derived products such as carbon monoxide and methane.(22,24,25) Even in systems that achieved >76% CO2 utilization…”
BackgroundElectrolytic Conversion of Bicarbonate into CO in a Flow Cell
Li, T., Lees, E. W., Goldman, M., Salvatore, D. A., Weekes, D. M., & Berlinguette, C. P. (2019) · Joule · doi:10.1016/j.joule.2019.05.021 · Cited by 361
Integrated CO2 Capture and Conversion to Formate and Methanol: Connecting Two Threads
Kar, S., Goeppert, A., & Prakash, G. K. S. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.9b00324 · Cited by 351
O’Brien, C. P., Miao, R. K., Liu, S., Xu, Y., Lee, G., Robb, A., Huang, J. E., Xie, K., Bertens, K., Gabardo, C. M., et al. (2021) · ACS Energy Letters · doi:10.1021/acsenergylett.1c01122 · Cited by 343 · cited 1×
“19,20 Enticingly, recent studies have overcome this CO2 utilization limit via local CO2 regeneration ; however, until now, the product gas stream has still been diluted by unreacted CO2 and gas-phase CO2-derived products such as carbon monoxide and methane.(22,24,25) Even in systems that achieved >76% CO2 utilization…”
BackgroundSelf-citationElectrochemical upgrade of CO2 from amine capture solution
Lee, G., Li, Y. C., Kim, J.-Y., Peng, T., Nam, D.-H., Sedighian Rasouli, A., Li, F., Luo, M., Ip, A. H., Joo, Y.-C., et al. (2020) · Nature Energy · doi:10.1038/s41560-020-00735-z · Cited by 298
Self-citationSocolow, R. H., Desmond, M. J., Aines, R. D., Blackstock, J. J., Bolland, O., Kaarsberg, T., Lewis, N. S., Mazzotti, M., Pfeffer, A., Sawyer, K., et al. (2011) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · Cited by 291
CO 2 Electroreduction from Carbonate Electrolyte
Li, Y. C., Lee, G., Yuan, T., Wang, Y., Nam, D.-H., Wang, Z., García de Arquer, F. P., Lum, Y., Dinh, C.-T., Voznyy, O., et al. (2019) · ACS Energy Letters · doi:10.1021/acsenergylett.9b00975 · Cited by 282 · cited 1×
“demonstrated pure syngas production with Faradaic efficiency (FE) of 30% CO and 70% H2, and with a Cu electrocatalyst, 14% C2 FE was observed.(5) The authors reported no appreciable loss of CO2 during carbonate electrolysis.”
BackgroundSelf-citationBrethomé, F. M., Williams, N. J., Seipp, C. A., Kidder, M. K., & Custelcean, R. (2018) · Nature Energy · doi:10.1038/s41560-018-0150-z · Cited by 262
Zhao, Y., Hao, L., Ozden, A., Liu, S., Miao, R. K., Ou, P., Alkayyali, T., Zhang, S., Ning, J., Liang, Y., et al. (2023) · Nature Synthesis · doi:10.1038/s44160-022-00234-x · Cited by 251
Self-citationHydroxide Based Integrated CO 2 Capture from Air and Conversion to Methanol
Sen, R., Goeppert, A., Kar, S., & Prakash, G. K. S. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.9b12711 · Cited by 237
Greenblatt, J. B., Miller, D. J., Ager, J. W., Houle, F. A., & Sharp, I. D. (2018) · Joule · doi:10.1016/j.joule.2018.01.014 · Cited by 226
Porous metal electrodes enable efficient electrolysis of carbon capture solutions
Zhang, Z., Lees, E. W., Habibzadeh, F., Salvatore, D. A., Ren, S., Simpson, G. L., Wheeler, D. G., Liu, A., & Berlinguette, C. P. (2022) · Energy & Environmental Science · doi:10.1039/d1ee02608a · Cited by 193
High-Rate and Efficient Ethylene Electrosynthesis Using a Catalyst/Promoter/Transport Layer
Ozden, A., Li, F., Garcı́a de Arquer, F. P., Rosas-Hernández, A., Thevenon, A., Wang, Y., Hung, S.-F., Wang, X., Chen, B., Li, J., et al. (2020) · ACS Energy Letters · doi:10.1021/acsenergylett.0c01266 · Cited by 180
Self-citationIdem, R. O., Supap, T., Shi, H., Gelowitz, D., Ball, M., Campbell, C., & Tontiwachwuthikul, P. P. (2015) · International journal of greenhouse gas control · doi:10.1016/j.ijggc.2015.06.005 · Cited by 160
Downstream of the CO 2 Electrolyzer: Assessing the Energy Intensity of Product Separation
Alerte, T., Edwards, J. P., Gabardo, C. M., O’Brien, C. P., Gaona, A., Wicks, J., Obradović, A., Sarkar, A., Jaffer, S. A., MacLean, H. L., et al. (2021) · ACS Energy Letters · doi:10.1021/acsenergylett.1c02263 · Cited by 143
Self-citationContinuum Model to Define the Chemistry and Mass Transfer in a Bicarbonate Electrolyzer
Lees, E. W., Bui, J. C., Song, D., Weber, A. Z., & Berlinguette, C. P. (2022) · ACS Energy Letters · doi:10.1021/acsenergylett.1c02522 · Cited by 108
Direct carbonate electrolysis into pure syngas
Xiao, Y. C., Gabardo, C. M., Liu, S., Lee, G., Zhao, Y. S., O’Brien, C. P., Miao, R. K., Xu, Y., Edwards, J. P., Fan, M., et al. (2022) · EES Catalysis · doi:10.1039/d2ey00046f · Cited by 91
Self-citationCarbonate Ion Crossover in Zero-Gap, KOH Anolyte CO2 Electrolysis
Mardle, P., Cassegrain, S., Habibzadeh, F., Shi, Z., & Holdcroft, S. (2021) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.1c08430 · Cited by 82
Kothandaraman, J., Lopez, J. S., Jiang, Y., Walter, É., Burton, S., Dagle, R. A., & Heldebrant, D. J. (2021) · ChemSusChem · doi:10.1002/cssc.202101590 · Cited by 69
Kaş, R., Yang, K., Yewale, G. P., Crow, A. M., Burdyny, T., & Smith, W. A. (2022) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.2c00352 · Cited by 63 · cited 1×
“:3) diffusion neutralize the acidic CEL surface, 29,30 31,32 The pH gradient was measured using pH-sensitive dyes (Note S5).”
Method
Metadata
- Authors
- Lee, G., Rasouli, A. S., Lee, B.-H., Zhang, J., Won, D. H., Xiao, Y. C., Edwards, J. P., Lee, M. G., Jung, E. D., Arabyarmohammadi, F., Liu, H., Grigioni, I., Abed, J., Alkayyali, T., Liu, S., Xie, K., Miao, R. K., Park, S., Dorakhan, R., Zhao, Y., O’Brien, C. P., Chen, Z., Sinton, D., & Sargent, E.
- Venue
- Joule
- Publisher
- Elsevier BV
- Published
- 2023-06
- Volume
- 7
- Issue
- 6
- Pages
- 1277-1288
- ISSN
- 2542-4351 (ISSN-L)
- OpenAlex
- W4378469979
- Cited by
- 174
- References
- 33
- FWCI
- 8.15
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.